Reference Manual V1.10
Software Versions 3.xx
X300-621-110
Page 39
NET: Network Communications.
AUTO: Enables 10 Hz automatic transmission using the format selected
below (SERIAL:FORMAT).
SINGLE: Enables transmission on pressing the
<PRINT>
key using the
format selected below (SERIAL:FORMAT). A long press of the
<PRINT>
key has no effect.
PRINT: Enables printer driving.
AUTO.PR: A single printout occurs when the weight is stable after being
at zero, and higher than the greater of 20 divisions or zero band.
Default: NET
FORMAT
(Serial Output
Format)
The Format determines the transmission format for AUTO and SINGLE
serial types.
FMT_1: Format 1 Condec.
FMT_2: Format 2 Ranger C.
MASTER: Send contents of LCD display to a remote display.
CUSTOM: Send a custom print string to a remote display.
FMT_3: Gedge C2
FMT_4: AnD
BAUD
(Serial Baud Rate)
The baud rate determines the serial data transmission speed.
Options are: 2400, 4800, 9600,19200
Default: 9600
BITS
(Serial Format
Options)
The Bits options allow the data transmission bit pattern and interface to be
changed. The display will show the current setting in the form
n81-
where
each character has a meaning as shown below.
Options are:
N or O or E: Parity bit: (N) None, (O) Odd, (E) Even
8, 7: Number of data bits
1, 2: Number of stop bits
-, D: DTR handshake disabled or enabled
Default: n81-. (For most applications the default setting is applicable.)
ADDRES
(Instrument
Address)
Use this option to set the instrument address when operating with network
communications.
Range 01 to 31
Default: 31
AUT.SPD
Auto Output Speed)
Use this option to set the Auto Output Speed for the instrument. There are
four speeds to choose from 10, 5, 2 & 1Hz. If using a remote input Auto
Output Speed must be set to 10Hz.
SHOW.T
(Show Totals)
The
SHOW.T
item stands for
Show Total
. When enabled the total will be
displayed following each printout. This can be useful if the function key is
being used for another purpose.
RST.CON
(Reset Printed
Consecutive
Number)
Use this option to reset the printed consecutive number back to
1
. The
instrument will prompt with
Cont. N
. Press
<EDT>
to change to
Cont. Y
and
<OK>
to continue. When
Cont. Y
has been chosen the instrument will
display
DONE
to indicate that the operation has been completed.