Reference Manual V1.10
Software Versions 3.xx
Page 36
X300-621-110
DEFLT
(Restore Factory Settings
Except for Calibration and
Build)
Restores all settings in the digital setup, which are not calibration
critical back to the original
new
settings installed at the factory. The
main use of this routine is to completely reset an instrument that is
being installed on a different scale. The instrument will prompt with
Cont. N
. Press
<EDT>
to change to
Cont. Y
and
<OK>
to
continue. When
Cont. Y
has been chosen the instrument will
display
DONE
to indicate that the operation has been completed.
Restoring the factory options does not affect the calibration. To
reset the calibration to factory condition CAL:FAC.CAL must be
used. Refer to FAC.CAL (Restore Default Factory Calibration)
page 32. This menu item is only available when in Full Digital
Setup mode.
8.4.8.
– End – (Leaving Setup)
Refer to Exiting Full or Safe Setup page 29.