CI-1500/1560A FEATURES
1. Features
n
High quality, High accuracy
n
Appropriate for weight and measurement system
n
Easy operation and various options
n
Display of 6 digit( 7 Segment)
n
RFI/EMI screened
n
WATCHDOG circuitry (System restoration)
n
WEIGHT BACK-UP ( Memory the weight at sudden power failure)
n
Store date, time and calculated data at sudden power failure
n
Adjustable display rate(Digital filter function)
n
Tare weight setting with keys
n
Users can set maximum weight which users want to and division at one's disposal
n
Self test hardware function
n
Independent zero calibration
n
External Input/Output -(CI-1560A)
: 2 External Input - (zero, F08)
4 External Output - (zero, 1 Step, 2 Step, Final)
n
Serial printer connection
n
Print date and time by inner clock
2. Main Function
TECHNICAL SPECIFICATION
Analog Part & A/D Conversion
Load cell Excitation Voltage
DC 5V
Zero adjust range
0.05 mV~30mV
Input Sensitivity
over 1
μ
V/D
Nonlinearity
0.01% F.S.
A/D internal resolution
1/100,000
A/D external resolution
1/10,000(Max.)
A/D conversion speed
10 times/sec
Digital Part
Span Calibration
Full Digital Calibration
(Single pass automatic span calibration)
Input noise
below 0.3
μ
Vpp
Input impedance
over 10
㏁
Display
7 Segment (6 digit)
Maximum Capacity
999999
Division
x 2, x 5, x 10, x 20, x 50
Display below zero
"-" minus signal
Permitted limit tare
Full capacity
Lamp
Description
" STABLE " LAMP
Weight is stable
" TARE " LAMP
Tare is used
" NET " LAMP
ON(NET weight), OFF(GROSS weight)
" HOLD " LAMP
Hold in Weight
" ZERO " LAMP
"0" kg
±