2
CELL SANICLEAR40
Electrolytic Chlorine Generator (Canada)
DOMESTIC
CONTROLS THE LEVEL OF BACTERIA AND ALGAE
in pools and hot tubs
REGISTRATION N
°
30794.
PEST CONTROL PRODUCT ACT.
READ THIS LABEL AND OPERATION AND INSTALLATION MANUAL BEFORE USING.
PRECAUTION:
A maximum of 170,000 Litres (45,000 Gallons) of water can be treated with one Cell SANICLEAR40 Chlorine generator system unit.
WARNING
Operating the SANICLEARSANICLEAR system without water flow through the SANICLEARSANICLEAR
system cell can cause a build‐up of flammable gases which can result in fire or explosion.
The SANICLEARSANICLEAR system protects itself against this condition via the FLO sensor by cutting off the power to the
SANICLEARSANICLEAR system cell whenever flow is not detected. The SANICLEARSANICLEAR system MUST be wired to the same circuit
as the filter pump. This ensures that the SANICLEARSANICLEAR system will only generate chlorine when the filter pump is providing
flow. The SANICLEARSANICLEAR system generates a maximum output of hypochlorous acid equivalent to 0.54 kg of free chlorine per
day.
KEEP OUT OF REACH OF CHILDREN
Do not use this device with bromide products
NOTICE TO USER!
This pest control product is to be used only in accordance with the directions on the label. It is an offence under the
Pest Control Products Act to use this product in a way that is inconsistent with the directions on the label.
SWITCH:
(The switch is ignored when operation is Remotely Controlled)
Super‐Chlorinate: Chlorine is produced at the maximum rate, regardless of the "Desired Output %" dial for the remainder of the
current filtering period (maximum 24 hours).
Auto: Chlorine is produced at the rate determined by the "Desired Output %" dial.
Off: Chlorine production is turned OFF. The power is controlled by the filter pump timer.
CHLORINE LEVEL DIAL:
(The Desired Output dial is ignored when operation is Remotely Controlled)
Adjust the "Desired Output
%"
dial to control the amount of chlorine produced. Periodically
check the pool chlorine level and adjust the dial up or down as required.
For swimming pools, an amount of 1‐3 ppm of free chlorine must be maintained.
For Hot tub, an amount of 3‐5 ppm of free chlorine must be maintained.
LCD DISPLAY: Displays salt level in ppm (parts per million).