10
M10077EN
DANGER: RISK OF ELECTRIC SHOCK THAT CAN RESULT IN SERIOUS INJURY OR DEATH.
Before proceeding with any wiring, the power at the circuit breaker must be turned off. Make sure to follow
all electrical codes (local and NEC). For safe operation, the Salt chlorinator must be installed properly by
being grounded and bonded.
Input power for stand-alone use:
VERY IMPORTANT
: The SANICLEAR system is to be powered only when the pump is running.
For proper wiring connections, refer to the diagram below and to the wiring label on Salt chlorinator. The salt
chlorinator is shipped with the 120V configuration jumpers stuck on the case cover. Until the jumpers are
installed for the desired voltage, the unit should NOT be turned on.
For Canada: Make sure the SANICLEAR chlorine generation system is connected to a circuit protected by a
ground fault interrupter class “A”. Make sure you connect the GROUND wire to the green ground screw
located on the INSIDE WALL of the enclosure.