T-340
7–40
7.27.4
Servicing the eAutoFresh Drive System
To replace the Drive Motor Assembly:
1. Remove the bolts that secure the eAutoFresh Panel (3,
) to the front of the unit. Reach in, cut tie
wrap, (2) and disconnect the motor connector (1). Bring panel to work area.
2. Remove four screws (8) fastening the grille (7).
3. Remove six screws (9) fastening the rails (5 and 11), the slide plate (10) and the gasket plate (6). Set com
-
ponents aside for reassembly.
4. Remove the four screws (12) fastening the motor cup (4) to the panel. Cut sealer on outside and inside of
motor cup assembly. Push out the motor cup assembly from the rear of the panel.
5. Mount the replacement motor cup assembly in the panel using original screws. Torque screws to 0.29 mkg
(25 +/- 1 Inch pounds).
6. Reapply sealer to the inside and the outside of the motor cup assembly.
7. Mount the upper & lower rails, slide plate and gasket plate using original hardware. Apply thread sealant
and torque screws to 0.29 mkg (25 +/- 1 Inch pounds).
8. Mount grille assembly using original hardware. Apply thread sealant and torque screws to 0.29mkg (25 +/- 1
Inch pounds).
9. Reconnect the motor connector.
10. Replace the bolts that secure the eAutoFresh Panel to the front of the unit.
11. Carry out functional test (see