7–41
T-340
Figure 7.25 Motor Cup Replacement
1) Connector
2) Tie Wrap
3) eAutoFresh Panel
4) Cup, Motor
5) Rail, Top
6) Plate, Gasket
7) Grille
8) Grill Screws
9) Rail Screws
10) Plate, Slide
11) Rail, Bottom
12) Motor Cup Screws
- - - - -
7.28 Electronic Partlow Temperature Recorder
The microprocessor-based temperature recorder is designed to interface with the DataCORDER to log tempera
-
ture with time. The electronic recorder will automatically record the return air, supply air, or both, based on the set
-
ting of temperature controller configuration code CnF37 (see
). The recorder reads and records data
from the controller in present time, under normal operating conditions.
If the power has been OFF for more than thirty days, the recorder will NOT re-synchronize (the chart will not
advance to present time), the pen tip will move to the currently recorded temperature, and the recorder will resume
normal temperature recording.