8
A12250
Fig. 13 -- Fan Coil Schematic
A12251
Fig. 14 -- In--line Fuse Installation Illustration
For mounting to fan coil air handlers:
1. Route the power conduit from the purifier to a knockout on
the fan coil air handler that provides access to the incoming
power wiring compartment. Affix the end of the conduit to
the fan coil air handler using the included conduit fitting.
2. Remove the yellow and black primary wires from the fan
coil air handler transformer terminals and connect the quick
connect “piggyback” terminals of the in-line fused leads ex-
iting the air purifier power conduit assembly to the trans-
former terminals. Reconnect the yellow and black primary
wires to their respective transformer terminals on the
“piggyback” terminals. Attach the ground ring terminal on
the third wire to fan coil air handler chassis ground. See
Figures 13 and 14.
NOTE
: Power connections are to be made inside the fan coil
wiring compartment per local electrical codes, and the two in-line
fuses that are provided with the air purifier must be installed in the
fan coil wiring compartment.
UNIT COMPONENT DAMAGE HAZARD
Failure to follow this caution may result in equipment
damage or improper operation.
For Furnace Purifiers:
Black Lead -- Connect to Hot (L1) or EAC--1 when
provided.
White Lead -- Connect to Neutral (L2) or EAC--2 when
provided.
Green/Ground Lead -- Connect to Appliance Ground
(Chassis).
For Fan Coil Purifiers:
Black Lead -- Connect to L1
White Lead -- Connect to L2
Green Lead -- Connect to Appliance Ground (Chassis)