HIGH VOLTAGE HAZARD

Failure to follow this warning could result in personal injury

or death.
This Air Purifier utilizes high voltage. If you notice water

running into or around the Air Purifier, water stains on the

purifier cartridge or on the Enhancement Module walls or

cabinet, shut off the Air Purifier and call your service provider.

!

WARNING

The Air Purifier is designed for use in the return air duct of a

forced air heating, cooling, and ventilation system. Although
designed to be a robust air purification system, the Air Purifier is

not designed to operate when wet. Operation of the Air Purifier in

a wet environment will result in less than optimal performance and
a possible safety hazard. As such, particular attention must be paid

to the following paragraphs regarding installation near air
conditioning coils and humidifiers.
The Air Purifier should be installed in a system so that all the

return air is circulated through the Air Purifier. It should be located
upstream of both the furnace and the air conditioning evaporator

coil. This will help keep the furnace and evaporator coil clean and
prevent condensation from forming within the Air Purifier.

Humidifiers

An evaporative humidifier can be mounted upstream of the Air

Purifier but the recommended location of any humidifier is
downstream of the Air Purifier. It is necessary to install atomizing

humidifiers downstream of the Air Purifier because hard water salt
deposits and water droplets may damage Air Purifier.
Ensure that the humidifier installation will not allow water or water

droplets to enter the Air Purifier because it may cause electrical
arcing or damage the Air Purifier.

NOTE

: For fan coil installations, do not install the humidifier in

the fan coil access doors or cabinet.
Inspect for plugged drains and maintain humidifier drain lines on a

regular basis to avoid overflow of water into the Air Purifier. The

recommended inspection should be done at every change of the
Air Purifier cartridge (generally 8--12 months).

HIGH VOLTAGE HAZARD

Failure to follow this warning could result in personal injury

or death.
This Air Purifier utilizes high voltage. If you notice water

running into or around the Air Purifier, water stains on the

purifier cartridge or on the Enhancement Module walls or

cabinet, shut off the Air Purifier and call your service provider.

!

WARNING

Transitions

If the return air duct or furnace openings do not fit the Air Purifier

cabinet openings, gradual transitions are recommended to reduce

air turbulence and maximize efficiency. No more than 45

_

(about

8.5 inches per running ft.) of expansion should be used on each

side of the transition fitting.

Turning Vanes

If the Air Purifier is installed adjacent to a 90

_

duct elbow, turning

vanes should be added inside duct to improve air distribution

across the face of the Air Purifier.

Electrical Power and Flow Sensing

The Air Purifier should only be powered when airflow is present.
The furnace control EAC terminals provide power only when the

furnace blower is operating. Air Purifier models PGAPAXX1625
and PGAPAXX2025 are designed to be powered from the

electronic air cleaner (EAC) terminals on a furnace electronic

control. If EAC terminals are not available, the Accessory Flow
Sensor Kit, model KIT--160--000, must be purchased for use with

the Air Purifier. Air Purifier models PGAPAXX1620,
PGAPAXX2020, and PGAPAXX2420 include the flow sensor as

standard equipment as they are designed primarily to be installed
with fan coil air handlers. A Flow Sensor Jumper Accessory Kit,

KIT--161--000 is available should there be a need to use Air

Purifier

model

PGAPAXX1620,

PGAPAXX2020,

or

PGAPAXX2420 with a furnace that has EAC terminals.

Electrical Power Fusing

Air Purifier models PGAPAXX1620, PGAPAXX2020, and
PGAPAXX2420 include in-line fuses necessary for installation

with fan coil air handlers. Air Purifier models PGAPAXX1625 and

PGAPAXX2025 do not include in-line fuses as they are designed
to be powered from the electronic air cleaner (EAC) terminals on a

furnace

electronic control,

which

are

already

properly

current-limited for Air Purifier application. If there is a need to use

Air Purifier model PGAPAXX1625 or PGAPAXX2025 with a

230VAC fan coil air handler or other high-current source, the
Accessory Fuse Kit KFAPS0110KIT must be ordered and installed

per the instructions included within the kit.

Accessory Safety Screen

ELECTRICAL OPERATION HAZARD

Failure to follow this warning could result in personal injury

or death.
The Air Purifier contains high voltage electrodes and as

supplied is designed to be installed in a completely enclosed

duct system in order to prevent access to high voltage during

operation of the purifier. If there is a need to operate the

purifier as the first element in a duct system (thereby locating

the inlet of the purifier in a position that could be touched

during operation), the Accessory Safety Screen Kit, listed in

the table below, must be purchased for use with the purifier.

!

WARNING

KIT MODEL NUMBER

AIR PURIFIER MODEL NUMBER

KIT---170---000

PGAPAXX1625

KIT---171---000

PGAPAXX2025

KIT---172---000

PGAPAXX1620

KIT---173---000

PGAPAXX2020

KIT---174---000

PGAPAXX2420

Duct Hardware Upstream of Purifier

Any equipment mounted in the duct or duct parts such as turning

vanes installed in the duct upstream of the purifier must be kept at
least 1.25 inches from the front face of the Air Purifier.

Summary of Contents for PGAPAXX1620

Page 1: ... Underwriters Laboratories Inc A11332 Fig 1 PGAP Unit SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause explosion fire electrical shock or other conditions which may cause death personal injury or property damage Consult a qualified installer service agency or your distributor or branch for information or assistance The qualified installer or ag...

Page 2: ... per running ft of expansion should be used on each side of the transition fitting Turning Vanes If the Air Purifier is installed adjacent to a 90_ duct elbow turning vanes should be added inside duct to improve air distribution across the face of the Air Purifier Electrical Power and Flow Sensing The Air Purifier should only be powered when airflow is present The furnace control EAC terminals pro...

Page 3: ...T 2 Ensure airflow direction through the Air Purifier matches the arrows on the face of the Air Purifier cart ridge and those on the label on the front of the cabinet The Air Purifier can be rotated 180_ to accommodate the cabinet orientation 3 The location of the Air Purifier should be readily accessible Enough room should be provided for periodic replacement of the Air Purifier cartridges ELECTR...

Page 4: ...dle latch at the bottom A11333 Fig 3 Air Purifier Cabinet Orientation Downflow 14 Furnace with Top Mount Upflow 14 Furnace with Bottom Mount Horizontal 14 Furnace with Side Mount Plenum Box Upflow Furnace with Plenum Box Horizontal 24 Furnace Downflow 24 Furnace with Top Mount Upflow 24 Furnace On Stand with Bottom Mount Upflow Furnace A11331 Fig 4 Air Purifier Cabinet Orientation with Transition ...

Page 5: ...When setting furnace on cabinet do not drop it into place Position the furnace correctly on the cabinet to prevent a corner from slipping down and damaging the cabinet or its components CAUTION 1 Turn off power to the heating and cooling system 2 Remove the existing furnace filter and discard Excessive system static may result if the Air Purifier is used with other filtration devices 3 Remove the ...

Page 6: ... flange of the purifier adjacent to the incoming power wir ing slide off the wiring cover as illustrated in Fig 9 The wiring cover must be reinstalled prior to operating the puri fier 8 Seal seams with tape or caulking after the Air Purifier cabi net has been secured Special consideration must be given when applying the 2025 Air Purifier to a 24 1 2 inch 622 mm wide furnace 1 Prepare transition fo...

Page 7: ...ng on furnaces 1 Route the power conduit from the purifier to a knockout on the furnace that provides access to the EAC terminals on the furnace control board Affix the end of the conduit to the furnace using the included conduit fitting 2 Attach the quick connect terminals on the wires exiting the power conduit assembly to the furnace EAC 1 and EAC 2 spade connections Attach the ground ring termi...

Page 8: ...lack primary wires to their respective transformer terminals on the piggyback terminals Attach the ground ring terminal on the third wire to fan coil air handler chassis ground See Figures 13 and 14 NOTE Power connections are to be made inside the fan coil wiring compartment per local electrical codes and the two in line fuses that are provided with the air purifier must be installed in the fan co...

Page 9: ...e purifier and then snap the Carrier or Bryant logo into place with the text in upright po sition See Fig 18 5 Affix the Captures Kills label to the front of the purifi er door as desired A11497 Fig 18 Attach Logo Checking Air Purifier Operation ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death Before installing or servicing system always turn off main...

Page 10: ...lace the Air Purifier cartridge complete the following steps Turn the heating and cooling system power off ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death Before installing or servicing system always turn off main power to system There may be more than one disconnect switch Lock out and tag switch with a suitable warning label WARNING NOTE Use of any...

Page 11: ...the Air Purifier Additionally care must be taken when handling the FEM due to the sharp points on the ionizer 5 Slide in enhancement module 6 Replace the Air Purifier door 7 Turn the Air Purifier switch to the on position 8 Turn heating and cooling system power on TROUBLESHOOTING SAFETY HAZARD Failure to follow this caution may result in personal injury or equipment damage The following instructio...

Page 12: ...s undamaged and properly installed on purifier cabinet Damaged or disconnected incoming power wiring Call for service ON continuously Air purifier on Normal operation when airflow is present FLASHING 1 flash every 4 seconds Standby Mode Normal operation when airflow is not present for models with flow sensor Ions detected in airflow due to miss ing replaceable filter element Place filter in air pu...

Page 13: ... Module FEM Clean service air purifier unit Damaged Filter Enhancement Module FEM Replace the filter enhancement module 5 FLASHES Over current fault Excessively dirty Damaged Filter Enhancement Module FEM and or filter Clean service air purifier unit Wet Damaged Filter Enhancement Module FEM and or filter Call service to locate and eliminate the source of water in the air purifier Verify that the ...

Page 14: ...ment Module FEM KIT 140 000 KIT 141 000 KIT 142 000 KIT 143 000 KIT 144 000 Front Door including Power Supply KIT 150 000 KIT 151 000 KIT 150 000 KIT 151 000 KIT 152 000 Flow Sensor KIT 160 000 Included as standard with Models PGAPAXX1620 PGAPAXX2020 and PGAPAXX2420 Flow Sensor Bypass KIT 161 000 Included as standard with Models PGAPAXX1625 and PGAPAXX2025 Front Screen Accessory KIT 170 000 KIT 17...

Page 15: ...15 ...

Page 16: ...C BDP D 7310 W Morris St D Indianapolis IN 46231 Edition Date 09 12 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No IM PGAP 01 Replaces NEW ...

Reviews: