Return Duct
Top Mount
Bottom Mount
Return Duct
Side Mount
A11368
Fig. 5 -- Mounting Air Purifier Cabinet
Mount Cabinet
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury
or death.
Before installing or servicing system, always turn off main
power to system. There may be more than one disconnect
switch. Lock out and tag switch with a suitable warning label.
!
WARNING
UNIT DAMAGE HAZARD
Failure to follow this caution may result in equipment
damage.
Cabinets will support a maximum weight of 400 lbs/181 kg
when installed beneath a vertical furnace or air--handling
unit. When setting furnace on cabinet, do not drop it into
place. Position the furnace correctly on the cabinet to prevent
a corner from slipping down and damaging the cabinet or its
components.
CAUTION
!
1. Turn off power to the heating and cooling system.
2. Remove the existing furnace filter and discard. Excessive
system static may result if the Air Purifier is used with other
filtration devices.
3. Remove the Air Purifier cartridge and enhancement module
from the Air Purifier cabinet. See Fig. 6 and 7.
4. If the air purifier is to be mounted in a side--flow applica-
tion, affix the adhesive--backed support foot to the side of
the purifier that will be on the floor, near the rear of the pur-
ifier, as shown in Fig. 8.
A11493
Fig. 6 -- Removing Filter
A11494
Fig. 7 -- Removing FEM
A11545
Fig. 8 -- Installation of Support Foot