ACCESSORIES

VENTILATOR ACCESSORY NUMBER NOMENCLATURE

1

2

3

4

5

6

7

8

9

10

11

12

K

V

B

C

N

0

1

0

1

C

B

S

Product

Control Description

CAU -- Carrier Automatic Control

KV -- Ventilator Accessory Kit

CBS -- Carrier Basic Control
CLC -- Carrier Latent Control
CLT -- Carrier OneTouch Control

Series

CST -- Carrier Standard Control

A -- Original Series
B -- Second Series

Accessory Description

HOD -- Intake Hood

Type

KIT -- Airflow Measuring Kit

AC01 -- Accessory

6FM -- Flow Collar 6--in.

CN01 -- Control

7FM -- Flow Collar 7--in.

TM01 -- Timer

8FM -- Flow Collar 8--in.

AC01 -- Accessory

Timer Description

Package Quantity

120C -- 20 Minute Timer Kit

01 -- Single Pack

160M -- 60 Minute Timer Kit

KIT NUMBER

DESCRIPTION

WHERE USED

KVBCN0101CAU

Automatic Wall Control

Used with HRVs

KVBCN0101CBS

Basic Wall Control

Used with HRVs

KVBCN0101CLC

Latent Wall Control

Used with ERVs

KVBCN0101CLT

Carrier OneTouch Control

Used with ERVs and HRVs as a main wall control

KVBCN0101CST

Standard HRV Control

Used with HRVs

KVAAC0101HOD

Exterior Intake and Exhaust Hood

Used with ERVs and HRVs, 2 Required

KVBAC0101KIT

Airflow Measuring Kit

Start up Balancing Kit, includes (2) 6 in. Flow Meter Collars & Magnehelic Gauge

KVATM010120C

20 Minute Push Button Timer

Used with ERVs and HRVs when 20 minute manual operation is required

KVATM010160M

60 Minute Timer

Used with ERVs and HRVs, time is adjustable between 10 and 60 minutes

KVAAC01016FM

6 in. Flow Meter Collar

Used with ERVs and HRVs, at start up, when 6 in. duct work is connected to HRV

KVAAC01017FM

7 in. Flow Meter Collar

Used with ERVs and HRVs, at start up, when 7 in. duct work is connected to HRV

KVAAC01018FM

8 in. Flow Meter Collar

Used with ERVs and HRVs, at start up, when 8 in. duct work is connected to HRV

Summary of Contents for ERVXXLHB1200

Page 1: ...air stream removes large airborne particles from the intake air stream before they enter the heat exchanger and reduces the maintenance required The units acoustically engineered design make Carrier v...

Page 2: ...rces Canada and the US EPA They meet ENERGY STAR requirements only when used in Canada Energy Star Canada All units in this document meet Energy Star Tier 2 reguirements in Canada except HRVXXLVU1330...

Page 3: ...elow 17 10 22 HVI RATED ENERGY PERFORMANCE MODEL MODE SUPPLY TEMP NET AIR FLOW POWER CONSUMED WATTS SENSIBLE RECOVERY EFFICIENCY APPARENT SENSIBLE EFFECTIVE NESS LATENT RECOVERY MOISTURE TRANSFER TOTA...

Page 4: ...27 Below 17 10 22 HVI RATED ENERGY PERFORMANCE MODEL MODE SUPPLY TEMP NET AIR FLOW POWER CONSUMED WATTS SENSIBLE RECOVERY EFFICIENCY APPARENT SENSIBLE EFFECTIVE NESS LATENT RECOVERY MOISTURE TRANSFER...

Page 5: ...93 Ends Enthalpic transfer media Cross flow 76 35 115 60 1 200 2 1 HRVXXLHB1150 66 163 31 77 Ends Polypropylene Cross flow 65 30 115 60 1 160 1 5 HRVXXLHB1250 82 204 39 96 Ends Polypropylene Cross flo...

Page 6: ...9 82 71 65 75 0 01 0 32 61 130 129 60 69 0 01 25 13 40 84 114 60 76 0 03 Cool 35 95 VENTILATION PERFORMANCE MODEL EXT STATIC PRESSURE NET SUPPLY AIR FLOW GROSS AIR FLOW SUPPLY EXHAUST Pa In w g L S CF...

Page 7: ...ERATURE DEFROST CYCLE MINUTES _C _F Defrosting Exchange HRVXXSVU1157 5 to 15 23 to 55 7 25 16 to 27 4 to 17 7 25 Below 27 Below 17 10 22 HVI RATED ENERGY PERFORMANCE MODEL MODE SUPPLY TEMP NET AIR FLO...

Page 8: ...330 300 334 142 158 Top Polypropylene Cross flow 145 66 115 60 1 500 5 4 DEFROST OPERATION MODEL OUTSIDE TEMPERATURE DEFROST CYCLE MINUTES _C _F Defrosting Exchange HRVXXLVU1330 5 to 15 23 to 55 6 60...

Page 9: ...5500 3215 3215 6430 9 15 2465 2465 3400 3899 6231 4870 3107 3107 6214 7 20 2195 2195 3000 3557 5684 4350 2834 2834 5669 4 25 1935 1935 2610 3215 5138 3850 2562 2562 5124 1 30 1680 1680 2250 2873 4591...

Page 10: ...10 Ventilator installed with forced air system A99297 Ventilator installed with independent air distribution A99298...

Page 11: ...nuous Low continuous wall control Vent wall control Vent low 40 min off High continuous Intermittent Intermittent 20 min on will operate in high will operate in high Low continuous No humidistat High...

Page 12: ...Control Used with HRVs KVBCN0101CLC Latent Wall Control Used with ERVs KVBCN0101CLT Carrier OneTouch Control Used with ERVs and HRVs as a main wall control KVBCN0101CST Standard HRV Control Used with...

Page 13: ...ties and enthalpy deviation lines are for ice 25 2 5 3 0 3 5 4 0 4 5 5 0 5 5 6 0 6 5 7 0 7 5 8 0 30 35 40 85 90 95 100 105 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 45 50 55 60...

Page 14: ...r Corp S 7310 W Morris St S Indianapolis IN 46231 Edition Date 07 12 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No...

Reviews: