Carrier ERVXXLHB1200 Product Data Download Page 7

7

HRVXXSVU1157

24 

9

/

16

(624 mm)

22 ½”

(572 mm)

14 

1

/

16

(358 mm)

14 

15

/

16

(380 mm)

18 ¼”

(464 mm)

2 ¹/

16

(53 mm)

23 

9

/

16

(599 mm)

13

/

16

(97 mm)

7

/

16

(189 mm)

NOTE: Every port fits 6” round duct.

1

: E

XHAUST AIR TO OUTSIDE

2

: F

RESH AIR FROM OUTSIDE

3

: E

XHAUST AIR FROM BUILDING

4

: F

RESH AIR TO BUILDING

3

4

2

1

P

OWER

CORD

3’

A12331

PHYSICAL & ELECTRICAL DATA

MODEL

CAPACITY (LO---HI)

PORT

LOC.

CORE

WEIGHT

LBS. [KG]

VOLTAGE

MAX

POWER

WATTS

MAX

AMPS

CFM

L/S

TYPE

AIR FLOW

HRVXXSVU1157

67 --- 170

32 --- 80

Top

Polypropylene Cross flow

56 [25]

115/60/1

125

1.0

DEFROST OPERATION

MODEL

OUTSIDE TEMPERATURE

DEFROST CYCLE (MINUTES

_

C

_

F

Defrosting

Exchange

HRVXXSVU1157

---5 to ---15

23 to 55

7

25

---16 to ---27

4 to ---17

7

25

Below ---27

Below ---17

10

22

HVI RATED ENERGY PERFORMANCE

MODEL

MODE

SUPPLY

TEMP

NET AIR

FLOW

POWER

CONSUMED

(WATTS)

SENSIBLE

RECOVERY

EFFICIENCY

APPARENT

SENSIBLE

EFFECTIVE-

NESS

LATENT

RECOVERY

MOISTURE

TRANSFER

_

C

_

F

L/S CFM

HRVXXSVU1157

Heat

0

32

32

67

56

70

78

0.00

0

32

40

86

64

68

75

0.01

0

32

56

120

86

64

70

0.01

---25

---13

30

63

79

61

83

0.01

VENTILATION PERFORMANCE

MODEL

EXT. STATIC PRESSURE

NET SUPPLY AIR FLOW

GROSS AIR FLOW

Supply

Exhaust

Pa

In w.g.

L/S

CFM

L/S

CFM

L/S

CFM

HRVXXSVU1157

25

0.1

91

193

92

195

91

194

75

0.3

80

170

81

171

80

169

100

0.4

74

157

74

158

74

157

150

0.6

62

132

62

133

63

133

200

0.8

47

101

48

101

49

104

Summary of Contents for ERVXXLHB1200

Page 1: ...air stream removes large airborne particles from the intake air stream before they enter the heat exchanger and reduces the maintenance required The units acoustically engineered design make Carrier v...

Page 2: ...rces Canada and the US EPA They meet ENERGY STAR requirements only when used in Canada Energy Star Canada All units in this document meet Energy Star Tier 2 reguirements in Canada except HRVXXLVU1330...

Page 3: ...elow 17 10 22 HVI RATED ENERGY PERFORMANCE MODEL MODE SUPPLY TEMP NET AIR FLOW POWER CONSUMED WATTS SENSIBLE RECOVERY EFFICIENCY APPARENT SENSIBLE EFFECTIVE NESS LATENT RECOVERY MOISTURE TRANSFER TOTA...

Page 4: ...27 Below 17 10 22 HVI RATED ENERGY PERFORMANCE MODEL MODE SUPPLY TEMP NET AIR FLOW POWER CONSUMED WATTS SENSIBLE RECOVERY EFFICIENCY APPARENT SENSIBLE EFFECTIVE NESS LATENT RECOVERY MOISTURE TRANSFER...

Page 5: ...93 Ends Enthalpic transfer media Cross flow 76 35 115 60 1 200 2 1 HRVXXLHB1150 66 163 31 77 Ends Polypropylene Cross flow 65 30 115 60 1 160 1 5 HRVXXLHB1250 82 204 39 96 Ends Polypropylene Cross flo...

Page 6: ...9 82 71 65 75 0 01 0 32 61 130 129 60 69 0 01 25 13 40 84 114 60 76 0 03 Cool 35 95 VENTILATION PERFORMANCE MODEL EXT STATIC PRESSURE NET SUPPLY AIR FLOW GROSS AIR FLOW SUPPLY EXHAUST Pa In w g L S CF...

Page 7: ...ERATURE DEFROST CYCLE MINUTES _C _F Defrosting Exchange HRVXXSVU1157 5 to 15 23 to 55 7 25 16 to 27 4 to 17 7 25 Below 27 Below 17 10 22 HVI RATED ENERGY PERFORMANCE MODEL MODE SUPPLY TEMP NET AIR FLO...

Page 8: ...330 300 334 142 158 Top Polypropylene Cross flow 145 66 115 60 1 500 5 4 DEFROST OPERATION MODEL OUTSIDE TEMPERATURE DEFROST CYCLE MINUTES _C _F Defrosting Exchange HRVXXLVU1330 5 to 15 23 to 55 6 60...

Page 9: ...5500 3215 3215 6430 9 15 2465 2465 3400 3899 6231 4870 3107 3107 6214 7 20 2195 2195 3000 3557 5684 4350 2834 2834 5669 4 25 1935 1935 2610 3215 5138 3850 2562 2562 5124 1 30 1680 1680 2250 2873 4591...

Page 10: ...10 Ventilator installed with forced air system A99297 Ventilator installed with independent air distribution A99298...

Page 11: ...nuous Low continuous wall control Vent wall control Vent low 40 min off High continuous Intermittent Intermittent 20 min on will operate in high will operate in high Low continuous No humidistat High...

Page 12: ...Control Used with HRVs KVBCN0101CLC Latent Wall Control Used with ERVs KVBCN0101CLT Carrier OneTouch Control Used with ERVs and HRVs as a main wall control KVBCN0101CST Standard HRV Control Used with...

Page 13: ...ties and enthalpy deviation lines are for ice 25 2 5 3 0 3 5 4 0 4 5 5 0 5 5 6 0 6 5 7 0 7 5 8 0 30 35 40 85 90 95 100 105 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 45 50 55 60...

Page 14: ...r Corp S 7310 W Morris St S Indianapolis IN 46231 Edition Date 07 12 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No...

Reviews: