HRVXXLVU1330

17 

9/16

[446.9]

3/ 4

[120.6]

1/8

″  

DIA

[206.4]

2 PLCS 

13/16

[147.6]

7/8

″ 

DIA

[148.2] 

2 PLCS

15/16

[176.2]

1/8

[181.0]

18 

5/16

[465.1]

3/16

″ 

[55.6] 

2 PLCS

12 

3/4

[323.9]

23 

15/16

[608.0]

43

(1092.2)

19 

1/16

[484.2]

3/16

[208.0]

3/16

[182.6]

DRAIN

11/16

DIA.

[17.5]
2 PLCS

24 

1/16

[611.2]

1/2

[38.1] 

2 PLCS

22 

3/8

[568.3]

41

[1041.4]

1

 ″ [

25.4]

2 PLCS

15 

1/2

[393.7]

3

1

2

4

NOTES:

1. FRESH AIR FROM OUTSIDE TO HRV

2. FRESH AIR FROM HRV TO HOUSE

3. STALE AIR FROM HOUSE TO HRV

4. STALE AIR FROM HRV TO OUTSIDE

WALL 
CONTROL
WIRING

3/8

 DIA

[9.5]

POWER 
CORD

A12332

PHYSICAL & ELECTRICAL DATA

MODEL

CAPACITY (LO---HI)

PORT

LOC.

CORE

WEIGHT

LBS. [KG]

VOLTAGE

MAX

POWER

WATTS

MAX

AMPS

CFM

L/S

TYPE

AIR FLOW

HRVXXLVU1330

300 --- 334 142 --- 158

Top

Polypropylene Cross flow

145 [66]

115/60/1

500

5.4

DEFROST OPERATION

MODEL

OUTSIDE TEMPERATURE

DEFROST CYCLE (MINUTES

_

C

_

F

Defrosting

Exchange

HRVXXLVU1330

---5 to ---15

23 to 55

6

60

---16 to ---27

4 to ---17

6

32

Below ---27

Below ---17

6

20

HVI RATED ENERGY PERFORMANCE

MODEL

MODE

SUPPLY

TEMP

NET AIR FLOW

POWER

CONSUMED

(WATTS)

SENSIBLE

RECOVERY

EFFICIENCY

APPARENT

SENSIBLE

EFFECTIVE-

NESS

LATENT

RECOVERY

MOISTURE

TRANSFER

_

C

_

F

L/S

CFM

HRVXXLVU1330

Heat

0

32

55

117

219

80

94

---0.07

0

32

86

183

290

74

86

0.02

0

32

117

249

436

70

83

---0.01

---25

---13

115

117

264

74

89

0.07

VENTILATION PERFORMANCE

MODEL

EXT. STATIC PRESSURE

NET SUPPLY AIR FLOW

GROSS AIR FLOW

Supply

Exhaust

Pa

In w.g.

L/S

CFM

L/S

CFM

L/S

CFM

HRVXXLVU1330

25

0.1

168

357

172

364

148

314

75

0.3

158

334

160

340

132

279

100

0.4

151

321

155

328

126

266

150

0.6

136

288

139

294

109

232

200

0.8

126

246

118

251

93

198

Summary of Contents for ERVXXLHB1200

Page 1: ...air stream removes large airborne particles from the intake air stream before they enter the heat exchanger and reduces the maintenance required The units acoustically engineered design make Carrier v...

Page 2: ...rces Canada and the US EPA They meet ENERGY STAR requirements only when used in Canada Energy Star Canada All units in this document meet Energy Star Tier 2 reguirements in Canada except HRVXXLVU1330...

Page 3: ...elow 17 10 22 HVI RATED ENERGY PERFORMANCE MODEL MODE SUPPLY TEMP NET AIR FLOW POWER CONSUMED WATTS SENSIBLE RECOVERY EFFICIENCY APPARENT SENSIBLE EFFECTIVE NESS LATENT RECOVERY MOISTURE TRANSFER TOTA...

Page 4: ...27 Below 17 10 22 HVI RATED ENERGY PERFORMANCE MODEL MODE SUPPLY TEMP NET AIR FLOW POWER CONSUMED WATTS SENSIBLE RECOVERY EFFICIENCY APPARENT SENSIBLE EFFECTIVE NESS LATENT RECOVERY MOISTURE TRANSFER...

Page 5: ...93 Ends Enthalpic transfer media Cross flow 76 35 115 60 1 200 2 1 HRVXXLHB1150 66 163 31 77 Ends Polypropylene Cross flow 65 30 115 60 1 160 1 5 HRVXXLHB1250 82 204 39 96 Ends Polypropylene Cross flo...

Page 6: ...9 82 71 65 75 0 01 0 32 61 130 129 60 69 0 01 25 13 40 84 114 60 76 0 03 Cool 35 95 VENTILATION PERFORMANCE MODEL EXT STATIC PRESSURE NET SUPPLY AIR FLOW GROSS AIR FLOW SUPPLY EXHAUST Pa In w g L S CF...

Page 7: ...ERATURE DEFROST CYCLE MINUTES _C _F Defrosting Exchange HRVXXSVU1157 5 to 15 23 to 55 7 25 16 to 27 4 to 17 7 25 Below 27 Below 17 10 22 HVI RATED ENERGY PERFORMANCE MODEL MODE SUPPLY TEMP NET AIR FLO...

Page 8: ...330 300 334 142 158 Top Polypropylene Cross flow 145 66 115 60 1 500 5 4 DEFROST OPERATION MODEL OUTSIDE TEMPERATURE DEFROST CYCLE MINUTES _C _F Defrosting Exchange HRVXXLVU1330 5 to 15 23 to 55 6 60...

Page 9: ...5500 3215 3215 6430 9 15 2465 2465 3400 3899 6231 4870 3107 3107 6214 7 20 2195 2195 3000 3557 5684 4350 2834 2834 5669 4 25 1935 1935 2610 3215 5138 3850 2562 2562 5124 1 30 1680 1680 2250 2873 4591...

Page 10: ...10 Ventilator installed with forced air system A99297 Ventilator installed with independent air distribution A99298...

Page 11: ...nuous Low continuous wall control Vent wall control Vent low 40 min off High continuous Intermittent Intermittent 20 min on will operate in high will operate in high Low continuous No humidistat High...

Page 12: ...Control Used with HRVs KVBCN0101CLC Latent Wall Control Used with ERVs KVBCN0101CLT Carrier OneTouch Control Used with ERVs and HRVs as a main wall control KVBCN0101CST Standard HRV Control Used with...

Page 13: ...ties and enthalpy deviation lines are for ice 25 2 5 3 0 3 5 4 0 4 5 5 0 5 5 6 0 6 5 7 0 7 5 8 0 30 35 40 85 90 95 100 105 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 45 50 55 60...

Page 14: ...r Corp S 7310 W Morris St S Indianapolis IN 46231 Edition Date 07 12 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No...

Reviews: