![background image](http://html1.mh-extra.com/html/carrier/comfortpro-pc6000/comfortpro-pc6000_operation-and-service-manual_2563807010.webp)
62-11175 COMFORTPRO SERVICE MANUAL
1-1
1.0 OPERATION OF MULTI-FUNCTION
DRIVER CONTROL PANEL
Figure 1-0: Multi-Function Driver Control Panel
APU
ON/OFF
HVAC
OFF
ESC/
RESET
MENU
A/C
FAN
HEAT
HOURS
00000
APU
SP
1
2
3
4
5
6
7
8
9
10
11
T
2
T
1
1.1.1 Multi-Function Driver Control Panel Components
1
When visible, the heating system is heating.
2
When visible, the A/C is cooling.
3
Indicates the number of operating hours on the APU.
4
Indicates the state of the APU.
The APU engine is running.
The APU engine is off.
The APU engine is in the starting process (flashing).
5
Indicates that Battery Monitor mode is enabled.
6
Indicates that maximum run time is enabled.
7
Indicates that Cold Weather Watch mode is enabled.
8
Indicates that Comfort Monitor mode is enabled.
9
Indicates that Timer 1 or Timer 2 mode is enabled.
10
Indicates that the ComfortPro is connected to shore power.
The APU cannot be started in Shore Power mode.
11
Indicates the state of the 115V outlet and CCU auto-reset breakers.
115 VAC power is being supplied to the outlet.
No power is being supplied to the outlet.
CCU breaker has tripped.
High Heat/Outlet breaker has tripped.
The breaker that tripped has reset automatically and the DCP needs
to be reset.
RE-
SET
TRIP
TRIP
OFF
T
2
T
1
APU
APU
APU
NOTICE
The DCP (driver control panel), which
is mounted inside the truck bunk,
controls the APU and the CCU. The
central panel on the DCP provides
status information using words
and icons:
PREPARATION
1.1