Table 4 – Dry Coil Air Delivery* - Horizontal and Downflow Discharge Sizes 24-60 208/230VAC 1 Phase Models 

Unit Size

Motor

Speed

Wire

Color

 

External Static Pressure (IN. W.C.)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

24

Low

Blue

CFM

669

580

525

423

303

---

---

---

---

---

BHP

0.09

0.10

0.11

0.11

0.12

---

---

---

---

---

Med-Low1

Pink

CFM

829

752

680

602

549

455

313

---

---

---

BHP

0.14

0.15

0.15

0.16

0.17

0.17

0.18

---

---

---

Medium

Red

CFM

1014

929

884

818

746

683

600

537

405

305

BHP

0.24

0.24

0.24

0.25

0.26

0.26

0.27

0.27

0.27

0.29

Med-High

Orange

CFM

1041

972

916

850

782

713

631

581

465

340

BHP

0.25

0.26

0.26

0.26

0.26

0.27

0.28

0.29

0.30

0.31

High

Black

CFM

1187

1124

1061

996

930

896

840

776

698

610

BHP

0.36

0.36

0.37

0.37

0.38

0.38

0.39

0.39

0.39

0.40

30

Low

Blue

CFM

669

580

525

423

303

---

---

---

---

---

BHP

0.09

0.10

0.11

0.11

0.12

---

---

---

---

---

Med-Low

Pink

CFM

829

752

680

602

549

455

313

---

---

---

BHP

0.14

0.15

0.15

0.16

0.17

0.17

0.18

---

---

---

Medium1

Red

CFM

1014

929

884

818

746

683

600

537

405

305

BHP

0.24

0.24

0.24

0.25

0.26

0.26

0.27

0.27

0.27

0.29

Med-High

Orange

CFM

1041

972

916

850

782

713

631

581

465

340

BHP

0.25

0.26

0.26

0.26

0.26

0.27

0.28

0.29

0.30

0.31

High

Black

CFM

1187

1124

1061

996

930

896

840

776

698

610

BHP

0.36

0.36

0.37

0.37

0.38

0.38

0.39

0.39

0.39

0.40

36

Low

Blue

CFM

1056

982

911

882

812

740

667

564

486

361

BHP

0.24

0.24

0.24

0.26

0.26

0.27

0.28

0.29

0.30

0.30

Med-Low

Pink

CFM

1174

1107

1045

985

914

890

825

760

673

572

BHP

0.32

0.32

0.33

0.33

0.34

0.35

0.36

0.37

0.37

0.37

Medium1

Red

CFM

1246

1195

1148

1081

1019

953

884

859

795

690

BHP

0.38

0.39

0.39

0.40

0.40

0.41

0.42

0.42

0.42

0.43

Med-High

Orange

CFM

1361

1299

1229

1210

1152

1092

1025

958

889

822

BHP

0.48

0.49

0.49

0.50

0.50

0.51

0.51

0.51

0.51

0.52

High

Black

CFM

1596

1542

1482

1424

1362

1304

1238

1173

1201

1143

BHP

0.74

0.74

0.74

0.75

0.75

0.75

0.76

0.76

0.77

0.77

42

Low

Blue

CFM

1001

902

833

777

717

650

575

527

466

419

BHP

0.13

0.13

0.14

0.14

0.15

0.16

0.17

0.18

0.19

0.20

Med-Low

Pink

CFM

1016

950

902

842

783

721

655

590

541

480

BHP

0.13

0.14

0.15

0.16

0.17

0.18

0.19

0.20

0.21

0.22

Medium1

Red

CFM

1403

1358

1316

1265

1217

1167

1116

1067

1012

956

BHP

0.29

0.30

0.31

0.33

0.34

0.35

0.36

0.37

0.38

0.39

Med-High

Orange

CFM

1461

1411

1367

1327

1275

1220

1174

1127

1074

1022

BHP

0.32

0.33

0.35

0.36

0.37

0.38

0.39

0.40

0.41

0.42

High

Black

CFM

1575

1528

1488

1447

1406

1360

1314

1264

1213

1159

BHP

0.40

0.42

0.43

0.44

0.45

0.46

0.47

0.48

0.49

0.50

48

Low

Blue

CFM

1378

1344

1295

1260

1216

1179

1135

1087

1035

995

BHP

0.26

0.27

0.29

0.31

0.31

0.33

0.34

0.36

0.36

0.38

Med-Low1

Pink

CFM

1696

1671

1631

1607

1574

1539

1507

1463

1432

1393

BHP

0.45

0.47

0.49

0.50

0.52

0.52

0.54

0.55

0.57

0.58

Medium

Red

CFM

1994

1968

1943

1910

1882

1835

1774

1702

1614

1512

BHP

0.72

0.73

0.75

0.76

0.78

0.78

0.76

0.73

0.70

0.66

Med-High

Orange

CFM

2054

2013

1986

1964

1919

1854

1779

1695

1605

1498

BHP

0.77

0.79

0.80

0.82

0.81

0.80

0.76

0.74

0.69

0.65

High

Black

CFM

2267

2201

2133

2071

1997

1923

1835

1739

1654

1551

BHP

1.03

1.00

0.97

0.93

0.89

0.86

0.82

0.78

0.74

0.69

Summary of Contents for Comfort 50VL-F

Page 1: ...refer to the current editions of the Canadian electrical Code CSA C22 1 Recognize safety information This is the safety alert symbol When you see this symbol on the unit and in instructions or manual...

Page 2: ...s and PE Professional Engineering Certificate if required Roof Curb Install accessory roof curb in accordance with instructions shipped with curb See Fig 4 Install insulation cant strips roofing and f...

Page 3: ...50VL C 50VL F Installation Instructions Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 3 A200004 Fig 2 24 36 Unit Dimensions...

Page 4: ...50VL C 50VL F Installation Instructions Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 4 A150533 Fig 3 42 60 Unit Dimensions...

Page 5: ...1 lb density Fig 4 Roof Curb Dimensions UNIT SIZE CATALOG NUMBER A IN mm B small common base IN mm B large base IN mm Part Number CPRCURB011B00 can be used on both small and large basepan units The cr...

Page 6: ...des Ducts passing through an unconditioned space must be insulated and covered with a vapor barrier If a plenum return is used on a vertical unit the return should be ducted through the roof deck to c...

Page 7: ...When using a gravel apron make sure it slopes away from the unit Connect a drain tube using a minimum of 3 4 in PVC or 3 4 in copper pipe all field supplied at the outlet end of the 2 in 51 mm trap D...

Page 8: ...nances Adhere to the following criteria when selecting sizing and installing the duct system 1 Units are shipped for side shot installation 2 Select and size ductwork supply air registers and return a...

Page 9: ...they do not interfere with operation of unit If an accessory electric heater is installed low voltage leads from heater must be connected to factory supplied control leads from Indoor Fan Board P4 con...

Page 10: ...7 3 17 4 7 3 17 4 7 3 17 5 6 INDOOR BLOWER Nominal Cooling Airflow Cfm Size in Size mm Motor HP RPM 800 10x10 254x254 1 2 1050 1000 10x10 254x254 1 2 1050 1150 11x10 279 4x254 3 4 1000 1350 11x10 279...

Page 11: ...rs start Observe that compressor and outdoor fan shut down when control setting is satisfied and that indoor blower shuts down after 90 second fan time delay expires IMPORTANT Three phase scroll compr...

Page 12: ...lor coding on the indoor fan motor leads see Table 3 The additional 4 speed tap wires are shipped loose with vinyl caps and are located in the control box near the interface fan board IFB See Fig 11 S...

Page 13: ...Y and G These completed circuits through the thermostat connect contactor coil C through unit wire Y and time delay relay TDR through unit wire G across the 24 V secondary of transformer TRAN The nor...

Page 14: ...d Low Pink CFM 1174 1107 1045 985 914 890 825 760 673 572 BHP 0 32 0 32 0 33 0 33 0 34 0 35 0 36 0 37 0 37 0 37 Medium1 Red CFM 1246 1195 1148 1081 1019 953 884 859 795 690 BHP 0 38 0 39 0 39 0 40 0 4...

Page 15: ...ation speed Table 5 Dry Coil Air Delivery Horizontal Discharge Sizes 36 60 3 Phase Models Only Unit Motor Speed Wire Color External Static Pressure IN W C 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 36 Low Bl...

Page 16: ...20 0 21 Med Low Pink CFM 1002 936 875 821 748 687 613 554 565 518 WATTS 144 155 161 171 176 187 193 203 209 220 BHP 0 15 0 17 0 17 0 18 0 19 0 20 0 21 0 22 0 22 0 24 Medium Red CFM 1255 1210 1145 1074...

Page 17: ...Black CFM 2480 2432 2375 2322 2236 2161 2085 2006 1917 1808 WATTS 1029 1012 995 975 941 908 869 836 796 751 BHP 1 10 1 09 1 07 1 05 1 01 0 97 0 93 0 90 0 85 0 81 Shaded areas indicate speed static co...

Page 18: ...Table IN W C Small Cabinet 24 36 STATIC STANDARD CFM SCFM 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 5 kW 0 00 0 00 0 00 0 00 0 00 0 00 0 00 0 00 0 02 0 04 0 06 0 07 10 kW 0 00 0 00 0 00...

Page 19: ...nstallation Instructions Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 19 A150503 Fig 12 Connection Wiring Diagram 24 36 60 Si...

Page 20: ...Installation Instructions Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 20 A150513 Fig 13 Ladder Wiring Diagram 24 36 60 Size...

Page 21: ...F Installation Instructions Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 21 A200013 Fig 14 Connection Wiring Diagram 30 Size...

Page 22: ...L F Installation Instructions Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 22 A200014 Fig 15 Ladder Wiring Diagram 30 Size 20...

Page 23: ...0VL F Installation Instructions Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 23 A150504 Fig 16 Connection Wiring Diagram 208...

Page 24: ...50VL F Installation Instructions Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 24 A150514 Fig 17 Ladder Wiring Diagram 208 23...

Page 25: ...50VL F Installation Instructions Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 25 A150505 Fig 18 Connection Wiring Diagram 46...

Page 26: ...C 50VL F Installation Instructions Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 26 A150515 Fig 19 Ladder Wiring Diagram 460...

Page 27: ...bulb indoor condition Where a dash appears do not attempt to check charge or charge unit under these conditions using the superheat method Weigh in method should be used A150625 To properly check or...

Page 28: ...ation in blower compartment d Ensure proper reassembly by marking blower wheel and motor in relation to blower housing before disassembly e Loosen setscrew s that secures wheel to motor shaft remove s...

Page 29: ...pose the fan blade 3 Inspect the fan blades for cracks or bends 4 If fan needs to be removed loosen the setscrew and slide the fan off the motor shaft 5 When replacing fan blade position blade as show...

Page 30: ...ditional safety hazards For models that have a scroll compressor the compressor pumps refrigerant throughout the system by the interaction of a stationary and an orbiting scroll The scroll compressor...

Page 31: ...rough the louvered openings in the unit base 4 Perform required service 5 Remove and dispose of any oil contaminated material per local codes Liquid Line Filter Drier The filter drier is specifically...

Page 32: ...rigerant evacuate system and recharge to capacities shown on rating plate Defective compressor Replace and determine cause Insufficient line voltage Determine cause and correct Blocked outdoor coil De...

Page 33: ...ELECTRICAL CONNECTIONS AND TERMINALS FOR TIGHTNESS CHECK THAT INDOOR EVAPORATOR AIR FILTER IS CLEAN AND IN PLACE VERIFY THAT UNIT INSTALLATION IS LEVEL CHECK FAN WHEEL AND PROPELLER FOR LOCATION IN H...

Page 34: ...dianapolis IN 46231 Edition Date 01 20 Catalog No 50VL 17SI Replaces 50VL 16SI 50VL C 50VL F Installation Instructions Manufacturer reserves the right to change at any time specifications and designs...

Reviews: