T H E R M I D I S TAT   C O N T RO L   C O N F I G U R AT I O N   R E C O R D

Date

Owner/Operator

A)  Hardware Configuration
  Switch A ____ AC/HP Select. (OFF = AC)
  Switch B ____ 1 or 2-Speed Compressor. (OFF = 1-Speed)
  Switch C ____ Smart Recovery. (OFF = Enable)
  Switch D ____ Installer Test. (OFF = Disable)

Thermidistat Model No.

B) Mode Settings

____  Hold (On or Off)
____  Mode (Off, Heat, Cool, Auto, Eheat)
____  Heating Set Point Value
____  Cooling Set Point Value
____  Fan (Auto or On)

C)  Configuration Options

D)  Schedule

E)  Humidity Settings
Heat Mode                 Cool Mode

Selection

Set Point%

Display

Normal Humidify

_________

(hu)

Fan Humidify

_________

(hu, Fan)

Auto Humidify

_________

(hu, AUTO)

Auto and Fan Humidify

_________

(hu, AUTO, Fan)

Humidify Off

no set point

(hu, OF)

1

______  Anticipator (1-9: factory default = 3)

2

______  Clean Filter Timer (Off or 1-9: factory default = 2)

3

______  Fahrenheit or Celsius (F or C: factory default = F)

4

______  Fan On with W (Off or On: factory default = Off)

5

______  Variable Speed ICM Motor (Off or On: factory default = Off)

6

______  Cooling Lockout Below 55

°

F (Off or On: factory default = Off)

7

______  Variable Speed Superdehumidify (Off or On: factory default = Off, or Not Available)

8

______  Auxiliary Heat Lockout Setting (Off or 5-55

°

F: factory default = Off, or Not Available)

9

______  Intelligent Heat Staging Selection (Off or On: factory default = Off, or Not Available)

10

______  Dual Fuel Equipment Selection (Off or On: factory default = Off, or Not Available)

11

______  Balance Point Setting (Off or 5-55

°

F: factory default = Off, or Not Available)

12

______  Defrost Heat Select (0, 1, 2, 3: factory default = 0, or Not Available)

13

______  Room Temperature Offset (-5 to +5: factory default = 0)

14

______  Heat/Cool Dead Band (0 to 6: factory default = 2)

15

______  Enable Auto Mode (On or Off: factory default = On)

16

______  Enable Super Comfort Heat Mode (Off or On: factory default is Off, or not Available)

17

______  Enable Non-Programmable Operation (nP or P: factory default is P for programmable)

Mon

Tue

Wed

Thu

Fri

Sat

Sun

TIME  HEAT  COOL

TIME  HEAT  COOL

TIME  HEAT  COOL TIME  HEAT  COOL

WAKE

DAY

EVE

SLEEP

A99015

   Selection

Set Point%

Display

   Normal Dehumidify

_________

(d hu)

   Cool to Dehumidify

_________

(d hu, COOL)

   Dehumidify Off

no set point

(d hu, OF)

E)  Vacation Humidity Settings
Heat Mode                 Cool Mode

Selection

Set Point%

Display

Normal Humidify

_________

(hu, OUT)

Auto Humidify

_________

(hu, OUT,AUTO)

Auto and Fan Humidify

_________

(hu, OUT,AUTO, Fan)

Humidify Off

no set point

(hu, OUT, OF)

   Selection

Set Point%

Display

   Normal Dehumidify

_________

(d hu, OUT)

   Cool to Dehumidify

_________

(d hu,OUT,COOL)

   Dehumidify Off

no set point

(d hu, OUT,OF)

Cut and Sa

v

e

 f

or Customer File

Copyright 1999 CARRIER Corp. • 7310 W. Morris St. • Indianapolis, IN 46231

tstt23si

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book 1

4

Tab

misc. misc.

PC 101

Catalog No. 03TS-TA17

Printed in U.S.A.

Form TSTAT-23SI

Pg 12

8-99

Replaces: TSTAT-19SI

Summary of Contents for CCPRHO1-B

Page 1: ...programmable configuration it will still have both tem perature and humidity control Humidify and dehumidify outputs provide direct control of humidity Batteries are not used During power loss an internal memory stores programs and settings for unlimited time and the clock continues to run for at least 8 hr INSTALLATION CONSIDERATIONS POWER Note that this control does not require batteries and is ...

Page 2: ...lects a special installer test mode which assists with system startup and checkout See Step 5 System Startup and Check out TO SET OFF for normal operation This is factory default ON for installer test mode Step 3 Install Thermidistat Control Before installing Thermidistat Control turn off all power to equipment There may be more than 1 power disconnect Electrical shock can cause personal injury or...

Page 3: ...ating that up and down buttons now control available choices within that option Each press of TIME TEMP button switches between available option small display and available selections within each option large display CONFIGURATION OPTIONS SELECTION Option 1 Anticipator Adjustment This adjustment controls sensitivity and cycle rate of Thermidistat Control Higher numbers decrease sensitivity and slo...

Page 4: ...ion demand without a cooling demand achieving maximum humidity removal with minimum cooling It is done by supplying blower with a Y signal and no G signal on a call for cooling Not all products with ICM blowers have this feature Check Installation Instructions for ICM air handler used Select OF for normal operation Y and G supplied on a cooling call Select ON for super dehumidification Y with no G...

Page 5: ...oint the heat pump is the most cost efficient to operate and below this point the furnace is the most cost efficient to operate This can be somewhat complicated to determine and it involves knowing the cost of gas and electricity as well as the efficiency of the furnace and heat pump For the most economical operation the heat pump should operate above this temperature assuming it has sufficient ca...

Page 6: ... than 2 may result in regular cycling between heat and cool when AUTO mode is selected However this cycling cannot occur more often than 1 transition every 20 minutes The system has a built in requirement that it cannot switch between heat and cool without a 20 minute off time between the 2 operations Specifically to switch from 1 mode to the other there must be no demand for the old mode and a de...

Page 7: ... keypad label over the original Make sure the new keypad label does not interfere with the motion of the buttons which it surrounds TO SELECT 1 Enter configuration mode if not already there See Step 4 To Enter Configuration Mode Use up and down buttons to make small now flashing display indicate 17 2 Press SET TIME TEMP button once to flash large display 3 Use up and down buttons to move between O...

Page 8: ...em to change with programmed schedule The FAN button may be used to select between AUTO fan on only with equipment and FAN fan on continuously fan modes For further information on temperature selection and program ming refer to Homeowner s Guide HUMIDITY CONTROL FEATURES The various humidity control features of the Thermidistat Control are explained below They are grouped into 2 sections humidifi ...

Page 9: ... no more while attempting to satisfy a dehumidify demand Within this 3 range there is an additional balance between overcooling and humidity satisfaction When overcooling must occur the dehumidify set point is adjusted upward by 2 percent per degree of overcooling For example a cooling set point of 76 F and a dehumidify set point of 60 percent is equivalent to a cooling set point of 75 F and a deh...

Page 10: ...am literature Carrier 58MVP Furnaces also have a DEHUM input The DE HUM input acts differently depending on which style of variable speed furnace control you have The older style variable speed furnace control DOES NOT have a DE connection while the newer style variable speed furnace control has a DE connection Both of these variable speed furnace controls function the same except the DEHUM logic ...

Page 11: ...and DHUM outputs When humidification or dehumidification is active the triangle under its set point is turned on AUTO CHANGEOVER When auto changeover mode is selected a change from heat to cool or vice versa will not occur until an opposite mode demand has existed for 20 minutes If set point is changed 20 minute requirement is deleted EMERGENCY HEAT MODE When Thermidistat Control is configured as ...

Page 12: ...f or On factory default Off or Not Available 11 ______ Balance Point Setting Off or 5 55 F factory default Off or Not Available 12 ______ Defrost Heat Select 0 1 2 3 factory default 0 or Not Available 13 ______ Room Temperature Offset 5 to 5 factory default 0 14 ______ Heat Cool Dead Band 0 to 6 factory default 2 15 ______ Enable Auto Mode On or Off factory default On 16 ______ Enable Super Comfor...

Reviews: