PHYSICAL DATA

UNIT SIZE SERIES

18

24

30

36

42

48

60

Operating Weight (lb)

125

125

134

152

189

210

236

Shipping Weight (lb)

146

146

155

175

218

235

270

Compressor Type

Scroll

REFRIGERANT

Puron

®

(R---410A)

Control

TXV (Puron

®

Hard Shutoff)

Charge (lb)

4.25

4.35

4.75

5.25

6.2

8.35

8.75

COND FAN

Propeller Type, Direct Drive

Air Discharge

Vertical

Air Qty (CFM)

1880

2200

2200

2950

3170

3365

4050

Motor HP

1/12

1/10

1/10

1/4

1/5

1/4

1/5

Motor RPM

1100

1100

1100

1100

1100

1100

825

COND COIL

Face Area (Sq ft)

9.85

9.85

11.49

14.77

17.25

21.56

25.15

Fins per In.

20

20

25

25

25

25

25

Rows

1

1

1

1

1

1

1

Circuits

3

3

3

3

4

5

5

VALVE CONNECT. (In. ID)

Vapor

5/8

5/8

3/4

3/4

7/8

7/8

7/8

Liquid

3/8”

3/8”

3/8”

3/8”

3/8”

3/8”

3/8”

REFRIGERANT TUBES* (In. OD)

Vapor (0---80 Ft Tube Length)

5/8

5/8

3/4

3/4

7/8

7/8

1---1/8

Liquid (0---80 Ft Tube Length)

3/8”

* For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline.

Note: See unit Installation Instruction for proper installation.

VAPOR LINE SIZING AND COOLING CAPACITY LOSS

PURON 1--STAGE AIR CONDITIONER APPLICATIONS

LONG LINE APPLICATION: An application is considered
”Long line” when the total equivalent tubing length exceeds 80 ft

or when there is more than 20 Ft vertical separation between
indoor and outdoor units. These applications require additional

accessories and system modifications for reliable system

operation. The maximum allowable total equivalent length is
250Ft. The maximum vertical separation is 200 Ft when outdoor

unit is above indoor unit, and up to 80 Ft when the outdoor unit
is below the indoor unit. Refer to Accessory Usage Guideline

below for required accessories. See Long--Line Application
Guideline for required piping and system modifications. Also,

refer to the table below for the acceptable vapor tube diameters

based on the total length to minimize the cooling capacity loss.

Unit Nominal Size

(Btuh)

Acceptable

Vapor Line

Diameters

(In. OD)

Cooling Capacity Loss (%)

Total Equivalent Line Length (ft)

Standard Application

Long Line Application Requires Accessories

25

50

80

80+

100

125

150

175

200

225

250

18000

1 Stage Puron AC

1/2

1

2

4

4

5

6

7

8

10

11

12

5/8

0

1

1

1

2

2

2

3

3

3

4

24000

1 Stage Puron AC

5/8

1

1

2

2

3

3

4

4

5

6

6

3/4

0

1

1

1

1

1

1

2

2

2

2

7/8

0

0

0

0

1

1

1

1

1

1

1

30000

1 Stage Puron AC

5/8

1

2

3

3

4

5

6

7

8

9

9

3/4

0

1

1

1

1

2

2

3

3

3

4

7/8

0

0

1

1

1

1

1

1

1

2

2

36000

1 Stage Puron AC

5/8

1

3

4

4

5

7

8

9

11

12

13

3/4

1

1

2

2

2

3

3

3

4

4

5

7/8

0

1

1

1

1

1

2

2

2

2

3

42000

1 Stage Puron AC

3/4

1

1

2

2

3

3

4

5

5

6

7

7/8

0

1

1

1

1

2

2

2

3

3

3

1 1/8

0

0

0

0

0

1

1

1

1

1

1

48000

1 Stage Puron AC

3/4

1

2

3

3

3

4

5

6

7

8

8

7/8

0

1

1

1

2

2

3

3

3

4

4

1 1/8

0

0

0

0

1

1

1

1

1

1

1

60000

1 Stage Puron AC

3/4

1

3

4

4

5

6

8

9

10

11

13

7/8

1

1

2

2

3

3

4

4

5

6

6

1 1/8

0

0

1

1

1

1

1

1

1

2

2

Standard Length = 80 Ft or less total equivalvent length

Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines

Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See

Long Line Application Guidelines

24AB

A

3

Summary of Contents for Base 24ABA3

Page 1: ...sories available Sound S Sound level as low as 76 dBA Comfort S System supports Thermidistatt or standard thermostat controls Reliability S Puronr refrigerant environmentally sound won t deplete the o...

Page 2: ...ISO 9001 2000 M A N U F A C T U R E R CERTIFIED TO ARI AS C O M P L Y I N G W I T H A RI STANDARD 210 U N I T A R Y AIR CO N D I T I O N I N G EQUIPMENT STANDARD FEATURES Feature 18 24 30 36 42 48 60...

Page 3: ...0 Ft when outdoor unit is above indoor unit and up to 80 Ft when the outdoor unit is below the indoor unit Refer to Accessory Usage Guideline below for required accessories See Long Line Application G...

Page 4: ...TOR FAN BALL BEARING X KSAHS1701AAA HARD START CAP RELAY X X X X X X X KSACY0101AAA CYCLE PROTECTOR X X X X X X X KSASF0101AAA SUPPORT FEET X X X X X X X KAACS0201PTC START ASSIST PTC X X X X X X X KA...

Page 5: ...designed to control condenser fan motor speed in response to the saturated condensing temperature during operation in cooling mode only For outdoor temperatures down to 20_F 28 9_C it maintains conde...

Page 6: ...tween unit and service panel for voltage drop not to exceed 2 Time Delay fuse FLA Full Load Amps LRA Locked Rotor Amps MCA Minimum Circuit Amps RLA Rated Load Amps NOTE Control circuit is 24 V on all...

Page 7: ...4 13 3 4 24ABA348 0 X 0 0 0 31 3 16 39 1 4 3 7 8 7 8 6 9 16 24 11 16 9 1 8 5 16 3 2 15 16 5 8 17 1 4 17 1 4 19 3 4 24ABA360 0 X 0 0 0 35 39 1 4 3 7 8 7 8 6 9 16 28 7 16 9 1 8 5 16 3 2 15 16 5 8 19 3...

Page 8: ...TDR TXV 14 00 11 70 58CV A X 090 16 CNPH 2417A 17 700 TXV 13 00 11 00 CNPH 2417A 17 500 TDR TXV 14 00 11 70 58MVB040 14 CNPH 2417A 17 500 TDR TXV 14 00 11 70 58MVB060 14 CNPH 2417A 17 600 TDR TXV 14 0...

Page 9: ...0 CNPV 3014A 22 800 TDR TXV 14 00 11 15 58CV A X 070 12 CNPV 3017A 23 000 TXV 13 00 11 00 CNPV 3017A 22 800 TDR TXV 14 00 11 70 58MVB060 14 CNPV 3017A 22 800 TDR TXV 14 00 11 70 58CV A X 090 16 CNPH 2...

Page 10: ...00 11 50 58MVB060 14 CAP 3017A 27 600 TDR TXV 14 00 11 50 58CV A X 090 16 CAP 3614A 27 000 TXV 13 00 11 00 CAP 3614A 26 600 TDR TXV 14 00 11 50 58CV A X 070 12 CAP 3617A 28 000 TXV 13 00 11 00 CAP 361...

Page 11: ...X 070 12 CAP 3617A 33 600 TDR TXV 14 00 11 50 58MVB060 14 CAP 3617A 33 600 TDR TXV 14 00 11 50 58CV A X 090 16 CAP 3621A 34 000 TXV 13 00 11 00 CAP 3621A 33 600 TDR TXV 13 50 11 20 58MVB080 14 CAP 362...

Page 12: ...21A 40 000 TDR TXV 13 50 11 20 58MVB080 14 CAP 4221A 40 500 TDR TXV 13 50 11 20 58CV A X 110 20 CAP 4224A 41 000 TXV 13 00 11 00 CAP 4224A 40 000 TDR TXV 13 50 11 20 58MVB040 14 CAP 4224A 40 500 TDR T...

Page 13: ...16 CAP 4821A 46 000 TXV 13 00 11 00 CAP 4821A 45 000 TDR TXV 13 20 11 00 58MVB080 20 CAP 4821A 45 000 TDR TXV 13 65 11 40 58MVB100 20 CAP 4821A 45 000 TDR TXV 13 50 11 20 58CV A X 110 20 CAP 4824A 46...

Page 14: ...000 TDR TXV 13 50 11 00 58CV A X 135 22 CNPV 6024A 56 500 TDR TXV 13 50 11 20 58CV A X 155 22 CNPH 6024A 57 000 TXV 13 00 11 00 CNPH 6024A 56 000 TDR TXV 13 50 11 20 58CV A X 135 22 CNPH 6024A 56 500...

Page 15: ...2 11 40 1 42 18 99 11 03 1 58 17 97 10 67 1 77 16 88 10 28 1 97 15 65 9 85 2 18 67 19 33 14 90 1 27 18 43 14 54 1 42 17 48 14 15 1 59 16 51 13 77 1 77 15 48 13 35 1 97 14 33 12 89 2 19 62 18 01 17 91...

Page 16: ...23 87 23 87 1 68 22 97 22 97 1 88 22 00 22 00 2 10 20 98 20 98 2 35 19 87 19 87 2 62 18 66 18 66 2 92 Multipliers for Determining the Performance With Other Indoor Sections Cooling Indoor Model Capaci...

Page 17: ...57 2 85 24 86 21 90 3 16 23 10 21 19 3 50 62 28 94 28 94 2 10 27 83 27 83 2 32 26 66 26 66 2 57 25 40 25 40 2 85 24 06 24 06 3 16 22 61 22 61 3 48 57 28 94 28 94 2 10 27 83 27 83 2 32 26 66 26 66 2 57...

Page 18: ...6 57 3 81 28 05 25 67 4 20 62 35 18 35 18 2 58 33 86 33 86 2 84 32 45 32 45 3 13 30 95 30 95 3 46 29 31 29 31 3 81 27 50 27 50 4 20 57 35 19 35 19 2 58 33 86 33 86 2 84 32 46 32 46 3 13 30 95 30 95 3...

Page 19: ...13 32 41 4 65 36 68 31 44 5 13 33 99 30 36 5 65 62 42 55 42 13 3 45 40 89 40 89 3 80 39 17 39 17 4 20 37 34 37 34 4 64 35 37 35 37 5 12 33 16 33 16 5 65 57 42 52 42 52 3 45 40 89 40 89 3 80 39 17 39 1...

Page 20: ...69 45 69 3 90 44 03 44 03 4 36 41 94 41 94 4 88 39 69 39 69 5 47 37 12 37 12 6 21 57 47 87 47 87 3 49 46 01 46 01 3 90 44 04 44 04 4 36 41 95 41 95 4 88 39 69 39 69 5 47 37 13 37 13 6 21 Multipliers...

Page 21: ...41 5 18 51 77 51 77 5 72 48 91 48 91 6 30 45 70 45 70 6 93 57 59 25 59 25 4 27 56 90 56 90 4 70 54 42 54 42 5 18 51 78 51 78 5 72 48 91 48 91 6 30 45 70 45 70 6 93 Multipliers for Determining the Per...

Page 22: ...ss B insulation and permanently lubricated bearings Shafts will be corrosion resistant Fan blades will be statically and dynamically balanced Condenser fan openings will be equipped with coated steel...