background image

4

ACCESSORY THERMOSTATS

THERMOSTAT / SUBBASE PKG.

DESCRIPTION

TSTATCCPRH01---B

Thermidistat Control --- Programmable / Non---Programmable Thermostat with Humidity control

TSTATCCPAC01---B

Thermostat --- Auto Changeover, 7---Day Programmable,

_

F/

_

C, 1---Stage Heat, 1---Stage Cool

TSTATCCNAC01---C

Thermostat --- Auto Changeover, Non---Programmable,

_

F/

_

C, 1---Stage Heat, 1---Stage Cool

TSTATCCBAC01---B

Builder’s Thermostat --- Manual Changeover, Non---Programmable,

_

F/

_

C, 1---Stage Heat, 1---Stage Cool

TSTATCCSEN01---B

Outdoor Air Temperature Sensor

TSTATXXBBP01

Backplate for Builder’s Thermostat

TSTATXXNBP01

Backplate for Non---Programmable Thermostat

TSTATXXPBP01

Backplate for Programmable Thermostat

TSTATXXCNV10

Thermostat Conversion Kit (4 to 5 wires) --- 10 Pack

ACCESSORIES

KIT NUMBER

DESCRIPTION

Size --- Voltage & Series

18---30

24---30

30---30

36---30

42---30

48---30

60---30

KAAFT0101AAA

FREEZE THERMOSTAT

X

X

X

X

X

X

X

KAATD0101TDR

TIME DELAY RELAY

X

X

X

X

X

X

X

KAAWS0101AAA

WINTER START

X

X

X

X

X

X

X

KSALA0301410

LOW AMBIENT PSW

X

X

X

X

X

X

X

KSALA0601AAA

MOTORMASTER 230V

X

X

X

X

X

X

X

KSALA0701AAA

MOTORMASTER 460V

HC32GE234

MOTOR FAN BALL BEARING

X

HC34GE239

MOTOR FAN BALL BEARING

X

X

HC40GE226

MOTOR FAN BALL BEARING

X

X

HC38GE219

MOTOR FAN BALL BEARING

X

HC40GE228

MOTOR FAN BALL BEARING

X

KSAHS1701AAA

HARD START (CAP / RELAY)

X

X

X

X

X

X

X

KSACY0101AAA

CYCLE PROTECTOR

X

X

X

X

X

X

X

KSASF0101AAA

SUPPORT FEET

X

X

X

X

X

X

X

KAACS0201PTC

START ASSIST PTC

X

X

X

X

X

X

X

KAACH1201AAA

CRANKCASE HTR

X

X

X

KAACH1401AAA

CRANKCASE HTR

X

X

X

X

KAACH1501AAA

CRANKCASE HTR

KSATX0201PUR

TXV PURON HSO

X

X

X

KSATX0301PUR

TXV PURON HSO

X

X

KSATX0401PUR

TXV PURON HSO

X

KSATX0501PUR

TXV PURON HSO

X

KSASH0601COP

SOUND HOOD

X

X

X

X

X

X

KSASH2101COP

SOUND HOOD

X

KAALP0301PUR

LOW PRESSURE SWITCH

X

X

X

X

X

X

X

KAAHI0401PUR

HIGH PRESSURE SWITCH

X

X

X

X

X

X

X

ACCESSORY USAGE GUIDELINE

ACCESSORY

REQUIRED FOR LOW---AMBIENT

COOLING APPLICATIONS (Below 55

°

F)

REQUIRED FOR

LONG LINE

APPLICATIONS*

(Over 80 Ft.)

REQUIRED FOR

SEA COAST

APPLICATIONS

(Within 2 miles)

Crankcase Heater

Yes

Yes

No

Evaporator Freeze Thermostat

Yes

No

No

Accumulator

No

No

No

Compressor Start Assist Capacitor and Relay

Yes

Yes

No

Motor Master

®

Control or Low---ambient

Pressure Switch

Yes

No

No

Support Feet

Recommended

No

Recommended

Liquid Line Solenoid Valve

No

See Long---Line Ap-

plication Guideline

No

Ball Bearing Fan Motor

Yes

{

No

No

* For tubing line sets between 80 and 200 ft. and/or 20 ft. vertical differntial, refer to Residential Split---System Longline Application Guideline.

{

Required for Low---Ambient Controller (full modulation feature) and MotorMaster

r

Control only.

Accessory Description and Usage (Listed Alphabetically)

24AB

A

3

Summary of Contents for Base 24ABA3

Page 1: ...sories available Sound S Sound level as low as 76 dBA Comfort S System supports Thermidistatt or standard thermostat controls Reliability S Puronr refrigerant environmentally sound won t deplete the o...

Page 2: ...ISO 9001 2000 M A N U F A C T U R E R CERTIFIED TO ARI AS C O M P L Y I N G W I T H A RI STANDARD 210 U N I T A R Y AIR CO N D I T I O N I N G EQUIPMENT STANDARD FEATURES Feature 18 24 30 36 42 48 60...

Page 3: ...0 Ft when outdoor unit is above indoor unit and up to 80 Ft when the outdoor unit is below the indoor unit Refer to Accessory Usage Guideline below for required accessories See Long Line Application G...

Page 4: ...TOR FAN BALL BEARING X KSAHS1701AAA HARD START CAP RELAY X X X X X X X KSACY0101AAA CYCLE PROTECTOR X X X X X X X KSASF0101AAA SUPPORT FEET X X X X X X X KAACS0201PTC START ASSIST PTC X X X X X X X KA...

Page 5: ...designed to control condenser fan motor speed in response to the saturated condensing temperature during operation in cooling mode only For outdoor temperatures down to 20_F 28 9_C it maintains conde...

Page 6: ...tween unit and service panel for voltage drop not to exceed 2 Time Delay fuse FLA Full Load Amps LRA Locked Rotor Amps MCA Minimum Circuit Amps RLA Rated Load Amps NOTE Control circuit is 24 V on all...

Page 7: ...4 13 3 4 24ABA348 0 X 0 0 0 31 3 16 39 1 4 3 7 8 7 8 6 9 16 24 11 16 9 1 8 5 16 3 2 15 16 5 8 17 1 4 17 1 4 19 3 4 24ABA360 0 X 0 0 0 35 39 1 4 3 7 8 7 8 6 9 16 28 7 16 9 1 8 5 16 3 2 15 16 5 8 19 3...

Page 8: ...TDR TXV 14 00 11 70 58CV A X 090 16 CNPH 2417A 17 700 TXV 13 00 11 00 CNPH 2417A 17 500 TDR TXV 14 00 11 70 58MVB040 14 CNPH 2417A 17 500 TDR TXV 14 00 11 70 58MVB060 14 CNPH 2417A 17 600 TDR TXV 14 0...

Page 9: ...0 CNPV 3014A 22 800 TDR TXV 14 00 11 15 58CV A X 070 12 CNPV 3017A 23 000 TXV 13 00 11 00 CNPV 3017A 22 800 TDR TXV 14 00 11 70 58MVB060 14 CNPV 3017A 22 800 TDR TXV 14 00 11 70 58CV A X 090 16 CNPH 2...

Page 10: ...00 11 50 58MVB060 14 CAP 3017A 27 600 TDR TXV 14 00 11 50 58CV A X 090 16 CAP 3614A 27 000 TXV 13 00 11 00 CAP 3614A 26 600 TDR TXV 14 00 11 50 58CV A X 070 12 CAP 3617A 28 000 TXV 13 00 11 00 CAP 361...

Page 11: ...X 070 12 CAP 3617A 33 600 TDR TXV 14 00 11 50 58MVB060 14 CAP 3617A 33 600 TDR TXV 14 00 11 50 58CV A X 090 16 CAP 3621A 34 000 TXV 13 00 11 00 CAP 3621A 33 600 TDR TXV 13 50 11 20 58MVB080 14 CAP 362...

Page 12: ...21A 40 000 TDR TXV 13 50 11 20 58MVB080 14 CAP 4221A 40 500 TDR TXV 13 50 11 20 58CV A X 110 20 CAP 4224A 41 000 TXV 13 00 11 00 CAP 4224A 40 000 TDR TXV 13 50 11 20 58MVB040 14 CAP 4224A 40 500 TDR T...

Page 13: ...16 CAP 4821A 46 000 TXV 13 00 11 00 CAP 4821A 45 000 TDR TXV 13 20 11 00 58MVB080 20 CAP 4821A 45 000 TDR TXV 13 65 11 40 58MVB100 20 CAP 4821A 45 000 TDR TXV 13 50 11 20 58CV A X 110 20 CAP 4824A 46...

Page 14: ...000 TDR TXV 13 50 11 00 58CV A X 135 22 CNPV 6024A 56 500 TDR TXV 13 50 11 20 58CV A X 155 22 CNPH 6024A 57 000 TXV 13 00 11 00 CNPH 6024A 56 000 TDR TXV 13 50 11 20 58CV A X 135 22 CNPH 6024A 56 500...

Page 15: ...2 11 40 1 42 18 99 11 03 1 58 17 97 10 67 1 77 16 88 10 28 1 97 15 65 9 85 2 18 67 19 33 14 90 1 27 18 43 14 54 1 42 17 48 14 15 1 59 16 51 13 77 1 77 15 48 13 35 1 97 14 33 12 89 2 19 62 18 01 17 91...

Page 16: ...23 87 23 87 1 68 22 97 22 97 1 88 22 00 22 00 2 10 20 98 20 98 2 35 19 87 19 87 2 62 18 66 18 66 2 92 Multipliers for Determining the Performance With Other Indoor Sections Cooling Indoor Model Capaci...

Page 17: ...57 2 85 24 86 21 90 3 16 23 10 21 19 3 50 62 28 94 28 94 2 10 27 83 27 83 2 32 26 66 26 66 2 57 25 40 25 40 2 85 24 06 24 06 3 16 22 61 22 61 3 48 57 28 94 28 94 2 10 27 83 27 83 2 32 26 66 26 66 2 57...

Page 18: ...6 57 3 81 28 05 25 67 4 20 62 35 18 35 18 2 58 33 86 33 86 2 84 32 45 32 45 3 13 30 95 30 95 3 46 29 31 29 31 3 81 27 50 27 50 4 20 57 35 19 35 19 2 58 33 86 33 86 2 84 32 46 32 46 3 13 30 95 30 95 3...

Page 19: ...13 32 41 4 65 36 68 31 44 5 13 33 99 30 36 5 65 62 42 55 42 13 3 45 40 89 40 89 3 80 39 17 39 17 4 20 37 34 37 34 4 64 35 37 35 37 5 12 33 16 33 16 5 65 57 42 52 42 52 3 45 40 89 40 89 3 80 39 17 39 1...

Page 20: ...69 45 69 3 90 44 03 44 03 4 36 41 94 41 94 4 88 39 69 39 69 5 47 37 12 37 12 6 21 57 47 87 47 87 3 49 46 01 46 01 3 90 44 04 44 04 4 36 41 95 41 95 4 88 39 69 39 69 5 47 37 13 37 13 6 21 Multipliers...

Page 21: ...41 5 18 51 77 51 77 5 72 48 91 48 91 6 30 45 70 45 70 6 93 57 59 25 59 25 4 27 56 90 56 90 4 70 54 42 54 42 5 18 51 78 51 78 5 72 48 91 48 91 6 30 45 70 45 70 6 93 Multipliers for Determining the Per...

Page 22: ...ss B insulation and permanently lubricated bearings Shafts will be corrosion resistant Fan blades will be statically and dynamically balanced Condenser fan openings will be equipped with coated steel...

Reviews: