24ABA3

Base

t

Series 13 Air Conditioner

with Puron

r

Refrigerant

Product Data

A04030

the environmentally sound refrigerant

Carrier’s Air Conditioners with Puron

r

refrigerant provide a

collection of features unmatched by any other family of
equipment. The 24ABA has been designed utilizing Carrier’s

Puron refrigerant. The environmentally sound refrigerant allows
you to make a responsible decision in the protection of the earth’s

ozone layer. Carrier’s air conditioning system with Puron
refrigerant meets the Energy Star

r

guidelines for energy

efficiency.

INDUSTRY LEADING

FEATURES / BENEFITS

Efficiency

S

13 SEER/11 EER

S

Microtube Technology

t

refrigeration system

S

Indoor air quality accessories available

Sound

S

Sound level as low as 76 dBA

Comfort

S

System supports Thermidistat

t

or standard thermostat

controls

Reliability

S

Puron

r

refrigerant -- environmentally sound, won’t

deplete the ozone layer and low lifetime servce cost.

S

Front--seating service valves

S

Scroll compressor

S

Internal pressure relief valve

S

Internal thermal overload

S

Filter drier

S

Balanced refrigeration system for maximum reliability

Durability

WeatherArmor

t

protection package:

S

Solid, Durable sheet metal construction

S

Dense wire coil guard

S

Baked--on, complete coverage, powder paint

Applications

S

Long--line -- up to 250 feet total equivalent length, up
to 200 feet condenser above evaporator, or up to 80 ft.

evaporator above condenser (See Longline Guide for
more information.)

S

Low ambient (down to --20

_

F) with accessory kit

Warranty

S

5 year limited compressor warranty

S

5 year limited parts warranty

Summary of Contents for Base 24ABA3

Page 1: ...sories available Sound S Sound level as low as 76 dBA Comfort S System supports Thermidistatt or standard thermostat controls Reliability S Puronr refrigerant environmentally sound won t deplete the o...

Page 2: ...ISO 9001 2000 M A N U F A C T U R E R CERTIFIED TO ARI AS C O M P L Y I N G W I T H A RI STANDARD 210 U N I T A R Y AIR CO N D I T I O N I N G EQUIPMENT STANDARD FEATURES Feature 18 24 30 36 42 48 60...

Page 3: ...0 Ft when outdoor unit is above indoor unit and up to 80 Ft when the outdoor unit is below the indoor unit Refer to Accessory Usage Guideline below for required accessories See Long Line Application G...

Page 4: ...TOR FAN BALL BEARING X KSAHS1701AAA HARD START CAP RELAY X X X X X X X KSACY0101AAA CYCLE PROTECTOR X X X X X X X KSASF0101AAA SUPPORT FEET X X X X X X X KAACS0201PTC START ASSIST PTC X X X X X X X KA...

Page 5: ...designed to control condenser fan motor speed in response to the saturated condensing temperature during operation in cooling mode only For outdoor temperatures down to 20_F 28 9_C it maintains conde...

Page 6: ...tween unit and service panel for voltage drop not to exceed 2 Time Delay fuse FLA Full Load Amps LRA Locked Rotor Amps MCA Minimum Circuit Amps RLA Rated Load Amps NOTE Control circuit is 24 V on all...

Page 7: ...4 13 3 4 24ABA348 0 X 0 0 0 31 3 16 39 1 4 3 7 8 7 8 6 9 16 24 11 16 9 1 8 5 16 3 2 15 16 5 8 17 1 4 17 1 4 19 3 4 24ABA360 0 X 0 0 0 35 39 1 4 3 7 8 7 8 6 9 16 28 7 16 9 1 8 5 16 3 2 15 16 5 8 19 3...

Page 8: ...TDR TXV 14 00 11 70 58CV A X 090 16 CNPH 2417A 17 700 TXV 13 00 11 00 CNPH 2417A 17 500 TDR TXV 14 00 11 70 58MVB040 14 CNPH 2417A 17 500 TDR TXV 14 00 11 70 58MVB060 14 CNPH 2417A 17 600 TDR TXV 14 0...

Page 9: ...0 CNPV 3014A 22 800 TDR TXV 14 00 11 15 58CV A X 070 12 CNPV 3017A 23 000 TXV 13 00 11 00 CNPV 3017A 22 800 TDR TXV 14 00 11 70 58MVB060 14 CNPV 3017A 22 800 TDR TXV 14 00 11 70 58CV A X 090 16 CNPH 2...

Page 10: ...00 11 50 58MVB060 14 CAP 3017A 27 600 TDR TXV 14 00 11 50 58CV A X 090 16 CAP 3614A 27 000 TXV 13 00 11 00 CAP 3614A 26 600 TDR TXV 14 00 11 50 58CV A X 070 12 CAP 3617A 28 000 TXV 13 00 11 00 CAP 361...

Page 11: ...X 070 12 CAP 3617A 33 600 TDR TXV 14 00 11 50 58MVB060 14 CAP 3617A 33 600 TDR TXV 14 00 11 50 58CV A X 090 16 CAP 3621A 34 000 TXV 13 00 11 00 CAP 3621A 33 600 TDR TXV 13 50 11 20 58MVB080 14 CAP 362...

Page 12: ...21A 40 000 TDR TXV 13 50 11 20 58MVB080 14 CAP 4221A 40 500 TDR TXV 13 50 11 20 58CV A X 110 20 CAP 4224A 41 000 TXV 13 00 11 00 CAP 4224A 40 000 TDR TXV 13 50 11 20 58MVB040 14 CAP 4224A 40 500 TDR T...

Page 13: ...16 CAP 4821A 46 000 TXV 13 00 11 00 CAP 4821A 45 000 TDR TXV 13 20 11 00 58MVB080 20 CAP 4821A 45 000 TDR TXV 13 65 11 40 58MVB100 20 CAP 4821A 45 000 TDR TXV 13 50 11 20 58CV A X 110 20 CAP 4824A 46...

Page 14: ...000 TDR TXV 13 50 11 00 58CV A X 135 22 CNPV 6024A 56 500 TDR TXV 13 50 11 20 58CV A X 155 22 CNPH 6024A 57 000 TXV 13 00 11 00 CNPH 6024A 56 000 TDR TXV 13 50 11 20 58CV A X 135 22 CNPH 6024A 56 500...

Page 15: ...2 11 40 1 42 18 99 11 03 1 58 17 97 10 67 1 77 16 88 10 28 1 97 15 65 9 85 2 18 67 19 33 14 90 1 27 18 43 14 54 1 42 17 48 14 15 1 59 16 51 13 77 1 77 15 48 13 35 1 97 14 33 12 89 2 19 62 18 01 17 91...

Page 16: ...23 87 23 87 1 68 22 97 22 97 1 88 22 00 22 00 2 10 20 98 20 98 2 35 19 87 19 87 2 62 18 66 18 66 2 92 Multipliers for Determining the Performance With Other Indoor Sections Cooling Indoor Model Capaci...

Page 17: ...57 2 85 24 86 21 90 3 16 23 10 21 19 3 50 62 28 94 28 94 2 10 27 83 27 83 2 32 26 66 26 66 2 57 25 40 25 40 2 85 24 06 24 06 3 16 22 61 22 61 3 48 57 28 94 28 94 2 10 27 83 27 83 2 32 26 66 26 66 2 57...

Page 18: ...6 57 3 81 28 05 25 67 4 20 62 35 18 35 18 2 58 33 86 33 86 2 84 32 45 32 45 3 13 30 95 30 95 3 46 29 31 29 31 3 81 27 50 27 50 4 20 57 35 19 35 19 2 58 33 86 33 86 2 84 32 46 32 46 3 13 30 95 30 95 3...

Page 19: ...13 32 41 4 65 36 68 31 44 5 13 33 99 30 36 5 65 62 42 55 42 13 3 45 40 89 40 89 3 80 39 17 39 17 4 20 37 34 37 34 4 64 35 37 35 37 5 12 33 16 33 16 5 65 57 42 52 42 52 3 45 40 89 40 89 3 80 39 17 39 1...

Page 20: ...69 45 69 3 90 44 03 44 03 4 36 41 94 41 94 4 88 39 69 39 69 5 47 37 12 37 12 6 21 57 47 87 47 87 3 49 46 01 46 01 3 90 44 04 44 04 4 36 41 95 41 95 4 88 39 69 39 69 5 47 37 13 37 13 6 21 Multipliers...

Page 21: ...41 5 18 51 77 51 77 5 72 48 91 48 91 6 30 45 70 45 70 6 93 57 59 25 59 25 4 27 56 90 56 90 4 70 54 42 54 42 5 18 51 78 51 78 5 72 48 91 48 91 6 30 45 70 45 70 6 93 Multipliers for Determining the Per...

Page 22: ...ss B insulation and permanently lubricated bearings Shafts will be corrosion resistant Fan blades will be statically and dynamically balanced Condenser fan openings will be equipped with coated steel...

Reviews: