background image

AQUASMART Room Controller

GB - 1

Installation manual

ENGLISH

This control system only operates with water indoor units of the following type:
42GW Cassette, 42WHC/WHE Hi-Wall, 42Y Fan coil, 42JW “Satellite” and 42EL “Aqualia”.
For installation instructions of this unit, refer to the relevant manuals.

Contents

Page

General information .................................................................................................................... 2

Choosing the installation site ...................................................................................................... 2

Installation .................................................................................................................................. 3

Electrical connections ................................................................................................................. 4

Room controller configuration ................................................................................................. 5/7

Troubleshooting .......................................................................................................................... 7

INSTALLATION FLOW CHART

Read manual

Install

Room Controller

Wire Room Controller

and unit network

Configure

Room Controller

Test System

Operate

Room Controller

Dimension (mm)

108

70

20

Summary of Contents for AQUASMART

Page 1: ...42GW 42WH 42Y 42JW 42EL 001 L L O Y D S R E G I S TER QUALIT Y A S S U R A N C E IS O 9001 AQUASMART Room Controller INSTALLATION MANUAL...

Page 2: ...For installation instructions of this unit refer to the relevant manuals Contents Page General information 2 Choosing the installation site 2 Installation 3 Electrical connections 4 Room controller co...

Page 3: ...se installation instructions are not observed Inspect equipment for damage due to improper transportation or handling file an immediate claim with the shipping company Do not install or use damaged un...

Page 4: ...lly at hinge to separate mounting base from remainder of the Room Controller Route the Room Controller wires through the large hole in the mounting base Level mounting base against wall for aesthetic...

Page 5: ...screws P DC Power G GROUND and C SIGNAL present on the rear base of the Room Controller P DC power G Ground C Signal Make the connections on the terminal block of the Room Controller as per diagram 2...

Page 6: ...2 will be displayed Press the DOWN button and the display will change to 1 up down up down 2 AIR SENSOR SELECTION Program if you want to use the air temperature sensor present in the Room Controller...

Page 7: ...on To perform this configuration proceed as follows Press and hold down the UP and DOWN keys at the same time for around 5 seconds Press UP button until 4 is displayed Press the MODE button to select...

Page 8: ...press any buttons for 10 seconds up down Troubleshooting 12 volts applied to Room Controller at the correct terminals and still does not operate Symptom Possible Cause Things to check Solution No LCD...

Page 9: ...nzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice Order No 16005 74 September 2001 Supersedes Order No 16005 74 Ma...