![background image](http://html1.mh-extra.com/html/carrier/69gl15-114/69gl15-114_operation-and-service_2563735016.webp)
2-1
SECTION 2
OPERATION
2.1 GENERATOR SET INSTALLATION AND REMOVAL
1
2
3
4
5
6
7
1. Bolt (1/2-13 x 2-1/2 lg Grade 8)
2. Flat Washer
3. Mounting Clip
4. Genset Mounting Bracket
5. Rectangular Washer
6. Locknut
7. Chassis I-beam
CHASSIS CENTER LINE
MOUNTING CLIPS
CHASSIS
MOUNTING CLIP
GENSET
GENSET BRACKET
SECTIONAL VIEW
EXPLODED VIEW
CURBSIDE VIEW
Figure 2-1. Generator Set Mounting
The Genset centered under the trailer chassis is easily
removed with a fork lift truck (Fork lift pockets are
provided) capable of handling 2000 pounds.
NOTES
1. When installing genset, torque mounting
bolts to 85-90 ft-lbs (11.75-12.44 mkg).
2. It is not recommended using original
locknuts for second installation.
a. Installation:
1. Place forks into fork lift pockets of generator set.
Attach safety chain between unit and fork truck.
2. Follow Figure 2-1 for installation of genset. Upon
completion, remove safety chain before removing forks
of fork lift truck from unit.
b. Removal:
1. Disconnect power cable to unit (if connected).
2. Disconnect fuel lines (if fuel tank is remote).
3. With fork lift in position and safety chain
attached remove hardware (see Figure 2-1) and then
remove genset.