52
Table 3 — Electrical Data With VAV Option (cont)
LEGEND
*The VAV option is not available on 62M040 units.
†Fused disconnect only.
**Exhaust and supply fan motors are 230-3-60.
UNIT SIZE
62M*
VFD
VOLTAGE
V-Ph-Hz
ERV
WHEEL
FLA
VFD
CURRENT
INPUT
VALUE
AMP
EXHAUST AND SUPPLY
FAN MOTOR
HEATER
SIZE
(kW)
POWER SUPPLY
PRE-HEATER
(Optional)
FLA
DISCONNECT
(Optional)
NEC - FLA
Hp
FLA
MCA
MOCP
Amps
Fuse Size†
Amps
285
208/230-3-60
0.6
8.2
6.8
2
—
17.39
20.57
26.74
—
40
25
5
29.95
36.28
39.31
12.57
60
35
8
37.49
45.70
46.85
20.11
45
10
42.52
51.99
51.99
25.13
50
460-3-60
4.2
3.4
—
8.82
10.42
13.54
—
30
12
5
15.11
18.27
19.82
6.28
17.5
8
18.88
22.98
23.59
10.05
20
10
21.39
26.12
26.12
12.57
40
25
575-3-60
3.6
2.7
—
7.66
8.97
11.66
—
30
10
5
12.68
15.26
16.69
5.03
15
8
15.70
19.03
19.71
8.04
17.5
10
17.71
21.54
21.72
10.05
20
330
208/230-3-60
1.2
8.2
6.8
2
—
17.99
20.57
26.74
—
40
25
8
38.09
45.70
46.85
20.11
60
45
10
43.12
51.99
51.99
25.13
50
15
55.69
67.70
67.70
37.70
80
60
460-3-60
4.2
3.4
—
9.15
10.42
13.54
—
30
12
8
19.20
22.98
23.59
10.05
20
10
21.71
26.12
26.12
12.57
40
25
15
28.00
33.98
33.98
18.85
30
575-3-60
3.6
2.7
—
7.83
8.97
11.66
—
30
10
8
15.87
19.03
19.71
8.04
18
10
17.88
21.54
21.72
10.05
20
15
22.91
27.82
27.82
15.08
40
25
430
208/230-3-60
1.2
11.3
9.6
3
—
24.03
28.13
36.56
—
60
35
8
44.14
53.26
56.67
20.11
80
50
10
49.16
59.54
61.69
25.13
60
15
61.73
75.25
75.25
37.70
100
70
460-3-60
5.6
4.8
—
12.07
14.06
18.28
—
30
18
8
22.12
26.63
28.33
10.05
40
25
10
24.63
29.77
30.85
12.57
30
15
30.91
37.62
37.62
18.85
60
35
575-3-60
4.8
3.9
—
10.29
12.05
15.66
—
30
15
8
18.33
22.10
23.71
8.04
20
10
20.34
24.61
25.72
10.05
25
15
25.37
30.90
30.90
15.08
40
30
550
208/230-3-60
1.2
17.8
15.2
5
—
37.16
44.53
57.89
—
80
50
8
57.26
69.66
78.00
20.11
100
70
10
62.29
75.95
83.02
25.13
80
15
74.85
91.65
95.59
37.70
200
90
460-3-60
9
7.6
—
18.73
22.40
29.11
—
40
25
8
28.78
34.96
39.17
10.05
60
35
10
31.30
38.10
41.68
12.57
40
15
37.58
45.96
47.96
18.85
45
575-3-60
7.6
6.1
—
15.83
18.97
24.66
—
30
20
8
23.87
29.02
32.70
8.04
40
30
10
25.88
31.54
34.71
10.05
30
15
30.91
37.82
39.74
15.08
60
35
ERV
—
Energy Recovery Ventilator
FLA
—
Full Load Amps
Hp
—
Horsepower
MCA
—
Minimum Circuit Amps
MOCP —
Maximum Overcurrent Protection
NEC
—
National Electric Code
N/A
—
Not Applicable
VFD
—
Variable Frequency Drive
Summary of Contents for 62MB