SAP ORDERING NO.

CASING

DIMENSIONS (IN.)

RATED HEATING

OUTPUT†

HEATING AIRFLOW

COOLING CFM

@ 0.5 ESP

(in. WC)

MOTOR HP-SPEED

APPROX SHIP

WEIGHT (LB)

H

D

W

(BTUH)

AFUE

CFM‡

Heating

ESP

(in. WC)

59SC2A040S14--10

35

29.5

14.2

39,000

92.1%

820

0.10

625-905

1/2 - 4

123

59SC2A060S14--10

35

29.5

14.2

58,000

92.1%

840

0.12

675-1130

1/2 - 4

127

59SC2A060S17--14

35

29.5

17.5

58,000

92.1%

980

0.12

650-1420

1/2 - 5

144

59SC2A080S17--16

35

29.5

17.5

78,000

92.1%

1040

0.15

810-1600

3/4 - 5

154

59SC2A080S21--20

35

29.5

21.0

78,000

92.1%

1500

0.15

1225-2025

3/4 - 5

162

59SC2A100S21--14

35

29.5

21.0

97,000

92.1%

1565

0.20

695-1565

3/4 - 5

169

59SC2A100S21--20

35

29.5

21.0

97,000

92.1%

1520

0.20

1225-2145

3/4 - 5

169

59SC2A120S24--20

35

29.5

24.5

117,000

92.1%

2065

0.20

1245-2065

3/4 - 5

186

† Capacity in accordance with DOE test procedures. See rating plate.

Heating CFM at factory default blower motor heating tap settings.

ESP --- External Static Pressure

FEATURES AND BENEFITS

HYBRID HEAT

R

Dual Fuel System

— This system can provide

more control over your monthly energy bills by automatically

selecting the most economical method of heating. With HYBRID
HEAT components, our system automatically switches between the

gas furnace and the single--stage electric heat pump as outside

temperatures change to maintain greater efficiency and comfort
than with any traditional single-source heating system. The heat

pump also delivers high-efficiency cooling in the summer.

Power Heat

t

Igniter

— Carrier’s unique SiN igniter is not only

physically robust but it is also electrically robust. It is capable of
running at line voltage and does not require complex voltage

regulators as do other brands. This unique feature further enhances

the gas furnace reliability and continues Carrier’s tradition of
technology leadership and innovation in providing a reliable and

durable product.

Reliable Heat Exchanger Design

— The aluminized steel,

clamshell primary heat exchanger was re--engineered to achieve

greater efficiency out of a smaller size. The first two passes of the
heat exchanger are based on the current 80% product, a design

with more than ten years of field-proven performance and success.
These innovations, paired with the continuation of a crimped,

no-weld seam create an efficient, robust design for this essential

component.
The condensing heat exchanger, a stainless steel fin and tube

design, is positioned in the furnace to extract additional heat.
Stainless steel coupling box componentry between heat exchangers

has exceptional corrosion resistance in both natural gas and
propane applications.

4-Way Multipoise Design

— One model for all applications –

there is no need to stock special downflow or horizontal models
when one unit will do it all. The new heat exchanger design allows

these units to achieve the certified AFUE in all positions.

Direct or Single-pipe Venting, or Optional Ventilated

Combustion Air

— This furnace can be installed as a 2-pipe

(Direct Vent) furnace, in an optional ventilated combustion air
application, or in single-pipe, non-direct vent applications. This

provides added flexibility to meet diverse installation needs.

Sealed Combustion System

— This furnace brings in combustion

air from outside the furnace, which results in especially quiet

operation. By sealing the entire combustion vestibule, the entire
furnace can be made quieter, not just the sound of the burners.

Monoport Burners

— The burners are specially designed and

finely tuned for smooth, quiet combustion and economical
operation.

Bottom Closure

— Factory-installed for side return; easily

removable for bottom return. The multi-use bottom closure can

also serve for roll-out protection in horizontal applications, and act

as the bottom closure for the optional return air base accessory.

Blower Access Panel Switch

— Automatically shuts off 115-v

power to furnace whenever blower access panel is opened.

Quality Registration

— Our furnaces are engineered and

manufactured under an ISO 9001 registered quality system.

Certifications

— This furnace is CSA (AGA and CGA) design

certified for use with natural and propane gases. The furnace is

factory--shipped for use with natural gas. A CSA listed gas
conversion kit is required to convert furnace for use with propane

gas. The efficiency is GAMA efficiency rating certified. This
furnace meets California Air Quality Management District

emission requirements.

59SC

2A

Summary of Contents for 59SC2A

Page 1: ...exchanger S High quality corrosion resistant prepainted steel cabinet with hemmed edges for safety S Factory configured ready for upflow applications S Direct vent sealed combustion single pipe venting or ventilated combustion air S PSC blower motor single speed inducer motor and single stage gas valve S Self diagnostics with SuperBrite LED S Approved for Twinning applications 60 14 through 120 60...

Page 2: ...gn with more than ten years of field proven performance and success These innovations paired with the continuation of a crimped no weld seam create an efficient robust design for this essential component The condensing heat exchanger a stainless steel fin and tube design is positioned in the furnace to extract additional heat Stainless steel coupling box componentry between heat exchangers has exc...

Page 3: ...tration System Field Supplied Filter Used for Certified Watt Data KGAWF1606UFR KGAWF1306UFR KGAWF1406UFR KGAWF1506UFR Electrical Data 040 10 060 10 060 14 080 16 080 20 100 14 100 20 120 20 Input Voltage Volts Hertz Phase 115 60 1 Operating Voltage Range Min Max 104 127 Maximum Input Amps Amps 6 8 7 0 8 4 9 6 14 5 7 6 14 6 14 9 Unit Ampacity Amps 9 5 9 7 11 5 13 0 19 1 10 4 19 2 19 6 Minimum Wire ...

Page 4: ...16 040 40 000 BTU 060 60 000 BTU 080 80 000 BTU 100 100 000 BTU 120 120 000 BTU Not all familes have these models 140 140 000 BTU A12040 FURNACE COMPONENTS RATING PLATE NOT SHOWN LOCATED ON BLOWER DOOR GAS VALVE MAIN LIMIT SWITCH BEHIND GAS VALVE REPRESENTATIVE DRAWING ONLY SOME MODELS MAY VARY IN APPEARANCE ELECTRICAL JUNCTION BOX IF REQUIRED LOCATION MAY VARY MEDIA CABINET OPERATING INSTRUCTIONS...

Page 5: ... designed system airflow and static pressure Use optional IAQ Device Duct Adapters as required 6 Available from Replacement Components group 7 Kit coming soon Expected availability 2Q2012 1 CSA requires that a termination kit be used See latest PD for pipe and kit size selection The qualified installer or agency must use only factory authorized kits when modifying these furnaces EZ Flex Cabinet Si...

Page 6: ...60 995 920 835 Orange 5 1130 1090 1045 1000 945 895 840 775 715 635 Red 5 900 855 800 750 695 640 590 525 470 405 100 20 BOTTOM or TWO SIDES 3 4 Black 2510 2420 2330 2240 2145 2040 1920 1805 1675 1520 Yellow 2030 2010 1970 1925 1870 1805 1725 1630 1525 1400 Orange 1655 1660 1650 1635 1615 1575 1520 1450 1360 1270 Blue 1520 1520 1520 1520 1500 1475 1430 1360 1290 1200 Red 1265 1255 1250 1240 1225 1...

Page 7: ...45 13 7 198 60 4 232 70 7 NA NA 60 000 27 8 2 127 38 7 222 67 7 250 76 2 NA 80 000 17 5 2 64 19 5 165 50 3 222 67 7 249 75 9 100 000 NA 22 6 7 104 31 7 223 68 0 250 76 2 120 000 NA NA 11 3 4 93 28 3 237 72 2 140 000 4 NA NA NA 80 24 4 185 56 4 3001 to 4000 914 to 1219 40 000 39 11 9 184 56 1 214 65 2 NA NA 60 000 23 7 0 119 36 3 210 64 0 235 71 6 NA 80 000 15 4 6 59 18 0 155 47 2 210 64 0 232 70 7...

Page 8: ...t equals the Maximum Equivalent Vent Length MEVL from Table 1 or Table 3 minus the number of elbows multiplied by the deduction for each elbow in Table 2 Standard vent terminations and concentric vent terminations count for zero deductions See Vent Manufacturers data for equivalent lengths of flexible vent piping DO NOT ASSUME that one foot of flexible vent pipe is equivalent to one foot of standa...

Page 9: ...8 63 19 2 8001 to 9000 2438 to 2743 40 000 10 3 0 121 36 9 130 39 6 NA NA 60 000 7 2 1 82 25 0 152 46 3 168 51 2 NA 80 000 NA 35 10 7 111 33 8 148 45 1 156 47 5 100 000 NA NA 67 20 4 157 47 9 170 51 8 120 000 NA NA NA 56 17 1 164 50 0 140 000 4 NA NA NA 23 7 0 42 12 8 9001 to 10 000 2743 to 3048 40 000 5 1 5 110 33 5 115 35 1 NA NA 60 000 NA 76 23 2 142 43 3 156 47 5 NA 80 000 NA 31 9 4 103 31 4 1...

Page 10: ...0 2 33 8 27 1 6 1 21 3 47 9 40 5 32 6 20 30 Ft 20 25 23 14 1 20 70 94 77 57 20 70 113 94 71 M 6 1 7 6 7 0 4 3 0 3 6 1 21 3 28 7 23 5 17 4 6 1 21 3 34 4 28 7 21 6 40 40 Ft 20 14 12 3 0 20 70 71 56 38 20 70 86 70 50 M 6 1 4 3 3 7 0 9 0 0 6 1 21 3 21 6 17 1 11 6 6 1 21 3 26 2 21 3 15 2 100000 20 10 Ft N A 25 99 89 78 N A 25 110 233 265 N A 25 110 235 229 M N A 7 6 30 2 27 1 23 8 N A 7 6 33 5 71 0 80 ...

Page 11: ...eat exchangers motors and controls 60 80 27 C 16 C SUPPLY AIR A10490 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS POSITION CLEARANCE Rear 0 0 mm Front Combustion air openings in furnace and in structure 1 in 25 mm Required for service 24 in 610 mm All Sides of Supply Plenum 1 in 25 mm Sides 0 0 mm Vent 0 0 mm Top of Furnace 1 in 25 mm Recommended COMBUSTION AIR PIPE FOR NON DIRECT 1 PIPE VENT APPLI...

Page 12: ... Coil Assembly or Coil Box 22 1 8 562 0 19 482 6 23 3 4 603 3 20 3 8 517 5 1 The plenum should be constructed 1 4 in 6 mm smaller in width and depth than the plenum dimensions shown above Concentric Vent Kit A93086 A concentric vent kit allows vent and combustion air pipes to terminate through a single exit in a roof or side wall One pipe runs inside the other allowing venting through the inner pi...

Page 13: ...NAL BLOCK THREE WIRE HEATING ONLY FIVE WIRE NOTE 1 NOTE 2 FIELD SUPPLIED DISCONNECT CONDENSING UNIT TWO WIRE FURNACE C O N T R O L R G COM W C R G Y GND GND FIELD 24 V WIRING FIELD 115 208 230 460 V WIRING FACTORY 24 V WIRING FACTORY 115 V WIRING 208 230 OR 460 V THREE PHASE 208 230 V SINGLE PHASE BLOWER DOOR SWITCH WHT BLK WHT BLK NOTES Connect Y terminal in furnace as shown for proper blower ope...

Page 14: ...14 DIMENSIONAL DRAWING A11593 59SC2A ...

Page 15: ...l have reusable type filters Filter shall be ______ in mm X ________ in mm An accessory highly efficient Media Filter is available as an option _____________ Media Filter Casing Casing shall be of 030 in thickness minimum pre painted galvanized steel Draft Inducer Motor Draft inducer motor shall be single speed design Primary Heat Exchangers Primary heat exchangers shall be 3 Pass corrosion resist...

Page 16: ...10 W Morris St S Indianapolis IN 46231 Printed in U S A Edition Date 01 12 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No 59SC2A 01PD Replaces New 59SC2A ...

Reviews: