58SP0A/58SP1A: Installation, Start–Up, Operating and Service and Maintenance Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
32
Unit Size: 045V17--16
Clg/CF Switch settings
External Static Pressure (ESP)
Clg Switches:
SW2-8
SW2-7
SW2-6
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Clg Default:
OFF
OFF
OFF
1525
1490
1445
1400
1350
1300
1250
1200
1140
1035
Cooling
(SW2-8,7,6)
OFF
OFF
ON
655
590
530
465
390
335
See Note 4
OFF
ON
OFF
825
770
715
665
615
560
495
445
395
350
OFF
ON
ON
1025
980
940
895
850
810
765
725
680
630
ON
OFF
OFF
1200
1160
1125
1085
1050
1010
975
935
900
860
ON
OFF
ON
1385
1350
1320
1285
1250
1215
1180
1145
1110
1030
ON
ON
OFF
1525
1490
1445
1400
1350
1300
1250
1200
1140
1035
ON
ON
ON
1525
1490
1445
1400
1350
1300
1250
1200
1140
1035
Maximum Clg Airflow
2
1525
1490
1445
1400
1350
1300
1250
1200
1140
1035
CF Switches
SW2-5
SW2-4
SW2-3
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Low-Clg Default:
OFF
OFF
OFF
655
590
530
465
390
335
See Note 4
Low-Cooling
(SW2-5,4,3)
OFF
OFF
ON
655
590
530
465
390
335
See Note 4
OFF
ON
OFF
825
770
715
665
615
560
495
445
395
350
OFF
ON
ON
1025
980
940
895
850
810
765
725
680
630
ON
OFF
OFF
1200
1160
1125
1085
1050
1010
975
935
900
860
ON
OFF
ON
1385
1350
1320
1285
1250
1215
1180
1145
1110
1030
ON
ON
OFF
1525
1490
1445
1400
1350
1300
1250
1200
1140
1035
ON
ON
ON
1525
1490
1445
1400
1350
1300
1250
1200
1140
1035
Cont. Fan Default:
OFF
OFF
OFF
655
590
530
465
390
335
See Note 4
Continuous Fan
(SW2-5,4,3)
OFF
OFF
ON
655
590
530
465
390
335
See Note 4
OFF
ON
OFF
825
770
715
665
615
560
495
445
395
350
OFF
ON
ON
1025
980
940
895
850
810
765
725
680
630
ON
OFF
OFF
1025
980
940
895
850
810
765
725
680
630
ON
OFF
ON
1025
980
940
895
850
810
765
725
680
630
ON
ON
OFF
1025
980
940
895
850
810
765
725
680
630
ON
ON
ON
1025
980
940
895
850
810
765
725
680
630
Heating (SW1)
Heat Airflow
3
925
875
830
780
735
685
635
590
540
490
Unit Size: 070V17--16
Clg/CF Switch settings
External Static Pressure (ESP)
Clg Switches:
SW2-8
SW2-7
SW2-6
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Clg Default:
OFF
OFF
OFF
1595
1560
1520
1485
1445
1410
1375
1335
1300
1265
Cooling
(SW2-8,7,6)
OFF
OFF
ON
660
585
515
445
370
See Note 4
OFF
ON
OFF
825
765
705
645
590
530
470
410
365
310
OFF
ON
ON
1025
970
915
860
810
760
705
640
585
530
ON
OFF
OFF
1225
1180
1135
1085
1040
995
950
910
865
820
ON
OFF
ON
1390
1350
1305
1265
1225
1180
1140
1100
1060
1020
ON
ON
OFF
1595
1560
1520
1485
1445
1410
1375
1335
1300
1265
ON
ON
ON
1855
1815
1785
1750
1720
1675
1625
1575
1525
1475
Maximum Clg Airflow
2
1855
1815
1785
1750
1720
1675
1625
1575
1525
1475
CF Switches
SW2-5
SW2-4
SW2-3
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Low-Clg Default:
OFF
OFF
OFF
660
585
515
445
370
See Note 4
Low-Cooling
(SW2-5,4,3)
OFF
OFF
ON
660
585
515
445
370
See Note 4
OFF
ON
OFF
825
765
705
645
590
530
470
410
365
310
OFF
ON
ON
1025
970
915
860
810
760
705
640
585
530
ON
OFF
OFF
1225
1180
1135
1085
1040
995
950
910
865
820
ON
OFF
ON
1390
1350
1305
1265
1225
1180
1140
1100
1060
1020
ON
ON
OFF
1595
1560
1520
1485
1445
1410
1375
1335
1300
1265
ON
ON
ON
1855
1815
1785
1750
1720
1675
1625
1575
1525
1475
Cont. Fan Default:
OFF
OFF
OFF
660
585
515
445
370
See Note 4
Continuous Fan
(SW2-5,4,3)
OFF
OFF
ON
660
585
515
445
370
See Note 4
OFF
ON
OFF
825
765
705
645
590
530
470
410
365
310
OFF
ON
ON
1025
970
915
860
810
760
705
640
585
530
ON
OFF
OFF
1025
970
915
860
810
760
705
640
585
530
ON
OFF
ON
1025
970
915
860
810
760
705
640
585
530
ON
ON
OFF
1025
970
915
860
810
760
705
640
585
530
ON
ON
ON
1025
970
915
860
810
760
705
640
585
530
Heating (SW1)
Heat Airflow
3
1395
1350
1310
1270
1230
1185
1145
1105
1065
1025
Table 13 – Air Delivery - CFM (With Filter)* (Continued)
COOLING
4
AND HEATING AIR DELIVERY - CFM (Bottom Return
5
with Filter)
(SW1-5 and SW2-2 set to OFF, except as indicated. See Notes 1 and 2.)