background image

                                                               ( 1 )

 

1. GENERAL INFORMATION 

 

PRECAUTIONS 

 

Installing and servicing of air conditioning equipment can be hazardous due to system 
pressure and electrical components. Only trained and qualified service personnel should 

install or service this equipment. 

 

Untrained personnel can perform basic maintenance function such as cleaning coil and 
filters. Trained service personnel should perform all other operations

 

When working on air conditioning equipment, observe precautions in the literature, tags 
and labels attached to the unit. 

 

 

WARNINGS 

 

The operating voltage of electrical power supply should be within the voltage mentioned on unit 
nameplate data

 

 

The capacity of electrical kWh counter should be larger than the operating currents required for 
air conditioner(s) and any other electrical domestic appliances in use simultaneously from the 

same supply.

 

 

 

The installation of electrical distribution box after the electrical KWH counter is necessary to 
properly distribute the electrical loads. The electrical distribution box should be equipped with 

circuit breakers according to the electrical loads. For each installed air conditioner, a separate 
circuit breaker with its own overload should be installed on the electrical distribution box.

 

 

 

The installation of two-pole automatic circuit breaker is necessary to operate the air conditioner. 
The circuit breaker must be installed to be far away from any flammable materials (curtains…etc.). 

The circuit breaker size must be suitable for air conditioner.

 

 

 

Disconnect the electrical mains supply prior to any maintenance operations or prior to handling 
any internal unit parts

 

 

The manufacturer declines any liability for damage resulting from modifications or errors in the 

electrical or refrigerant connections, made during the installation, or from the improper use of this 
equipment. This will void the unit warranty immediately.

 

 

 

Failure to observe electrical safety codes may cause a fire hazard in case of short circuits.

 

 

 

This system will only work safety and correctly, if installed and tested by qualified personnel.

 

 

 

Do not open the electronic remote controller to avoid possible damage. In case of malfunction 

contact a qualified service engineer.

 

 

 

The unit contains rotating equipment (fan). Ensure that this is out of reach for children.

 

 

 

Be conscious of the room temperature and general comfort, particularly when this is used near 
children, senior or handicapped people.

 

 

 

For correct use, the air conditioner must operate within the temperature limits indicated in the 
table “Operating Limits” included in the installation manual. Incorrect use of the system outside 

these limits may cause malfunction and dripping water.

 

 

 

Controller batteries contain polluting elements. When exhausted, they must be disposed of in 
accordance with local requirements.

 

 

 

Do not switch off the split system by disconnecting the electric power supply.

  

 

The system must always be switched off using the remote control.

 

Summary of Contents for 53VMCT 18C-24C-30C-36C

Page 1: ...MANUAL Carrier is committed to continuously improving its products according to national and international standards to ensure the highest quality and reliability standards and to meet market regulat...

Page 2: ...l Air Flow Manual Direction Auto Fan Speed Vertical Air Flow Auto Swing Auto Mode Efficient AMS Efficient Fans Efficient Coils Inner Groove Copper Tubing Tropical Compressor IAQ AMS Auto 3 Minutes Tim...

Page 3: ...uality IAQ Harmony is the very latest in slim line technology CONTENTS PAGE NO 1 GENERAL INFORMATION 1 2 SYSTEM SAFETY PROTECTIONS 2 3 TIPS OF ENERGY SAVING AND OPTIMUM COMFORT 3 4 SPLIT SYSTEM DESCRI...

Page 4: ...installed to be far away from any flammable materials curtains etc The circuit breaker size must be suitable for air conditioner Disconnect the electrical mains supply prior to any maintenance operat...

Page 5: ...the power failure is happened during the air conditioner operation the microprocessor of printed circuit board will memorize the operation setting After the power is recovered the air conditioner ope...

Page 6: ...the air conditioner for heating before that Don t exaggerate on the temperature intensity too hot Extreme temperatures are harmful to your health and waste energy Keep doors windows and any other open...

Page 7: ...tioned Clean periodically air filter of indoor unit every two weeks to assure adequate air circulation and maximum cooling or heating efficiency Periodic service and maintenance of the air conditioner...

Page 8: ...ng status leds 6 Supply air outlet 3 Supply air flap 7 Characteristics nameplate 4 Air return grille 8 Refrigerant piping lines and electrical cables 5 Air filter behind return grille 9 Condensate dra...

Page 9: ...oor unit or transmission indicator on the remote control fails to light 6 Batteries should only be replaced after turning OFF the air conditioner 5 2 INSTRUCTIONS OF USING WIRELESS REMOTE CONTROL 1 Th...

Page 10: ...ctive and the unit is immediately restarted after a stop this LED flashes until a new signal is sent to the indoor unit RED LED 3 gives the following information During normal operation the LED is OFF...

Page 11: ...ctive and the unit is immediately restarted after a stop this LED flashes until a new signal is sent to the indoor unit RED LED 3 gives the following information During normal operation the LED is OFF...

Page 12: ...you press The time alters as quickly as you press the button Keep pressing the button without releasing the time moves forward or backward by 10 minutes depending on which side you press 3 CLOCK butt...

Page 13: ...control display OPERATION led will illuminate on the display panel of indoor unit COOL mode starts after approximately 3 minutes STOP If you want to stop the air conditioner Press ON OFF button again...

Page 14: ...ote control display OPERATION led will illuminate on the display panel of indoor unit HEAT mode starts after approximately 3 minutes STOP If you want to stop the air conditioner Press ON OFF button ag...

Page 15: ...ystem When Auto mode is activated the air conditioner changes the operation mode automatically to cool or heat or fan only mode and also changes fan speed to auto speed by sensing the temperature diff...

Page 16: ...luminate on the display panel of indoor unit DRY mode starts after approximately 3 minutes STOP If you want to stop the air conditioner Press ON OFF button again NOTES In DRY mode you can not switch t...

Page 17: ...F button to start the air conditioner ON symbol appears on the remote control display OPERATION led will illuminate on the display panel of indoor unit FAN ONLY mode starts immediately STOP If you wan...

Page 18: ...rform this function while the unit is in operation Keep pressing the AIR DIRECTION button on the remote control to move the louver to the desired In subsequent operations the vertical air flow is auto...

Page 19: ...selected Then the set temperature will be automatically increased by another 1 C after additional 1 hour This new temperature will be maintained Stop If you want to cancel SLEEP function press any oth...

Page 20: ...displayed Each time you press there the button the time moves forward or backward by 10 minutes depending on which one you press The time alters as quickly as you press the button 3 After setting the...

Page 21: ...you press the button the time moves forward or backward by 10 minutes depending on which one you push The time alters as quickly as you press the button 3 After setting the time for TIMER ON function...

Page 22: ...TIME button to display 6 00 beside the TIMER ON indicator Wait 3 seconds the TIMER ON time will be registered 3 Press TIMER button again until TIMER OFF indicator is displayed and setting time is flas...

Page 23: ...MER OFF indicator is displayed and the setting time is flashing 2 Use the TEMP TIME button to display 23 00 beside the TIMER OFF indicator of the remote control Wait 3 seconds the TIMER OFF time will...

Page 24: ...function when you want to prevent settings from being changed accidentally 2 When you press TEMP and buttons as the same time all current settings are locked in and the remote control does not accept...

Page 25: ...r position To remove air filters 1 Open the return grille without removing the two screws and the central clamp from their position 2 Remove filters 2 Remove air filters for cleaning CLEANING OF STAND...

Page 26: ...ared control using a damp cloth 9 2 INDOOR COIL CLEANING It is recommended to clean the coil at least at the beginning of each cooling season or when necessary turn the unit off first Use a vacuum cle...

Page 27: ...l batteries 4 Outdoor Unit Every Month Every Year Clean outdoor coil 2 Blow air over electric parts 2 Check electric connection tightening 2 Clean fan wheel 2 Check fan tightening 2 Clean drain pan 2...

Page 28: ...s case you must switch the system off and air filters must be cleaned Restart the unit in ventilation fan only mode and open windows to change the room air 5 The air conditioner turns to FAN only mode...

Page 29: ...ssing any function button the remote control shows the function requested on the display but unit does not acknowledge signal receipt with a beep and does not carry out the function Main switch is OFF...

Page 30: ...he room temperature in the cooling mode Correct selected temperature Air conditioner is not supplying enough heating Air flow cannot circulate freely Remove obstructions Dirty filters reduce air quant...

Page 31: ...4 5 9 1 8 10 6 3 7 Signal transmission indicator 1 Operating mode indicator 2 Automatic heat pump model only AUTO Cooling and dehumidification COOL Dehumidification only DRY Heating heat pump models...

Page 32: ...SPEED selection button 4 ON OFF button 5 SWING horizontal flap button 6 AIR DIRECTION horizontal flap button 7 SLEEP function button 8 CLOCK adjusting button 9 TIMER ON or TIMER OFF function button 1...

Reviews: