25
•
Lift the front panel up to the top of the unit and then it will be separated
from the unit.
•
Detach the Terminal block cover and clamp wire. ( Figure. 7 )
•
Connect the electrical connection cord with the screws to the terminal block
of the indoor unit as described at Figure. 8.
( Refer to the Wiring Diagram inside the Frame grille and Caution Label on the
frame grille. Caution Label is engraved on Frame grille )
•
Reinstall the clamp wire and the terminal block cover with the screws
after wiring.
•
Fit the front panel to the latch of the Frame grille.
For Cooling Only Model
Figure 7
•
Do not connect wires when power is ON.
•
The air conditioner always requires grounding. Ground the unit must be in
accordance with local codes.
•
Every wire must be connected firmly. Use connection cable H07(H05, A07,
A05)RN-F 1.5mm
2
, synthetic rubber insulation with Neoprene coating,
according to EN(IEC) 60335-2-40 and HD277.S1 standards.
•
Wrong wiring causes malfunction of the unit and electric shock. Check
local electrical codes and also any specific wiring instructions or limitation.
•
During installation, proceed first with refrigerant connections between in
door and outdoor units, and only then make the electrical ones; similarly,
when disassembling, disconnect the electrical wiring first and only then
open refrigerant connections.
•
Unit must be installed according to applicable national installation standards.
CAUTION
For Heat Pump Model
Figure 8
3) Indoor Unit Wiring
INDOOR UNIT INSTALLATION