The unit does not operate.

Cooling is abnormally low.

 

The power main switch is 
turned off. 

 

The circuit breaker is 
activated to cut off the power 
supply. 

 

Stoppage of electric current. 

 

ON timer is set.

 

The 

fi

lters are blocked with dust. 

 

T h e   t e m p e r a t u r e   h a s   b e e n   s e t 
improperly. 

 

The windows or doors are opened. 

 

The air inlet or outlet of the outdoor unit 
is blocked. 

 

The fan speed is too low. 

 

The operation mode is FAN or DRY.

TROUBLESHOOTING (CHECK POINT)

REMOTE CONTROL A-B SELECTION

To separate using of remote control for each indoor unit in case of 2 air 
conditioners are installed nearly.

Remote Control B Setup.

  1. Press RESET button on the indoor unit to turn the air conditioner ON.
  2. Point the remote control at the indoor unit.
  3. Push and hold 

 button on the Remote Control by the tip of the 

pencil. “00” will be shown on the display .  (  Picture     )

 4. 

Press 

MODE

 during pushing 

. “B” will show on the display and 

“00” will disappear and the air conditioner will turn OFF. The Remote 
Control B is memorized. (  Picture     )

Note:  1. Repeat above step to reset Remote Control to be A.
 

2. Remote Control A has not “A” display.

 

3. Default setting of Remote Control from factory is A.

1

2

AUTO RESTART OPERATION

14

To automatically restart the air conditioner after the power failure (Power of 
the unit must be on.)

Setting

  1. Press and hold the RESET button on the indoor unit for 3 seconds to set 

the operation. (Pi Pi Pi sound and OPERATION lamp blink 5 time/sec for 
5 seconds)

  2. Press and hold the RESET button on the indoor unit for 3 seconds to 

cancel the operation. (Pi Pi Pi sound but OPERATION lamp does not 
blink)

 

In case of ON timer or OFF timer are set, AUTO RESTART OPERATION 
does not activate.

19

20

For ECO sleep automatically control air 

fl

 ow and automatically turn OFF.

 Press 

: Select 1, 3, 5 or 9 hrs for OFF timer operation.

Note:

  The cooling operation, the set temperature will increase automatically 

1 degree/hour for 2 hours (maximum 2 degrees increase).

ECO SLEEP OPERATION

 Firstly, turn off the circuit breaker.

Indoor Unit and Remote Control

 

Clean the indoor unit and the remote control with a wet cloth when needed.

 

No benzine, thinner, polishing powder or chemically-treated duster.

Air 

fi

 lters

Clean every 2 weeks.

1. Open the air inlet grille.
2. Remove the air 

fi

 lter.

3. Vacuum or wash and then dry them.
4. Reinstall the air 

fi

 lters and close the air inlet grille.

MAINTENANCE

OPERATION AND PERFORMANCE

  1. Three-minute protection feature: To prevent the unit from being activated 

for 3 minutes when suddenly restarted or switched to ON. 

  2. Some minor cracking sound may occur when unit operating. This is 

normal because the cracking sound may be caused by expansion/
contraction of plastic.

Air conditioner operating conditions

Temp.

Operation

Outdoor Temperature

Room Temperature

Cooling

-10°C ~ 46°C

21°C ~ 32°C

Dry

-10°C ~ 46°C

17°C ~ 32°C

SELF CLEANING OPERATION 
(COOL AND DRY OPERATION ONLY)

To protect bad smell caused by the humidity in the indoor unit.

 1. 

If 

the 

 button is pressed once during “Cool” or “Dry” mode, 

the fan will continue to run for other 30 minutes, then it will turn off 
automatically. This will reduce the moisture in the indoor unit.

  2. To stop the unit immediately, press the 

 more 2 times within 

30 seconds.

15

16

17

18

1

2

@TeddyAir 095-323-9555 

www.TeddyAirCond.com

Summary of Contents for 42TVGS010-703

Page 1: ...ENGLISH AIR CONDITIONER SPLIT TYPE For general public use Indoor unit 42TVGS010 013 016 703 Outdoor unit 38TVGS010 013 016 703 OWNER S MANUAL R32 1118350223 TeddyAir 095 323 9555 www TeddyAirCond com...

Page 2: ...re may be generated in the refrigeration cycle which may result in a failure or explosion of the product or an injury to your body Do not use means to accelerate the defrosting process or to clean oth...

Page 3: ...F Timer 1 Press Set the desired ON timer Press Set the desired OFF timer 2 Press Set the timer Press Set the timer 3 Press Cancel the timer Press Cancel the timer Daily timer allows the user to set bo...

Page 4: ...ATION does not activate To operate at super low fan speed for quiet operation except in DRY mode Press Start and stop the operation Note Under certain conditions QUIET operation may not provide adequa...

Page 5: ...TH 2 1 2 1 2 2 AAA 1 2 2 3 1 2 3 4 5 9 8 1 2 3 6 7 4 1 2 3 4 5 6 7 8 9 Reset 1 2 3 3 R 1 1 TIMER 2 OPERATION R M h Amin m2 Amin m2 Amin M 2 5 x 0 22759 x h0 2 3 TeddyAir 095 323 9555 www TeddyAirCond...

Page 6: ...GH 7 1 MODE 2 6 1 MODE 2 17 C 3 AUTO LOW LOW MED MED HIGH 9 DRY FAN ONLY 1 1 2 2 8 DRY FAN ONLY 10 RESET AUTOMATIC 24 C 11 1 2 3 1 ON 3 2 OFF 4 15 13 1 2 3 P 3 12 1 3 LCD 2 4 LCD 100 50 50 50 50 5 Ted...

Page 7: ...2 3 00 4 MODE B 00 B 1 A 2 A A 3 A 1 2 QUIET 1 3 5 9 1 1 2 2 16 2 1 2 3 4 17 15 14 1 RESET 3 3 OPERATION 5 5 2 RESET 3 3 ON OFF 19 1 3 2 10 C 46 C 21 C 32 C 10 C 46 C 17 C 32 C 18 1 30 2 2 30 TeddyAi...

Page 8: ...1118350223 TeddyAir 095 323 9555 www TeddyAirCond com...

Page 9: ...ENGLISH AIR CONDITIONER SPLIT TYPE For general public use Indoor unit 42TVGS018 024 703 Outdoor unit 38TVGS018 024 703 OWNER S MANUAL R32 1120650208 TeddyAir 095 323 9555 www TeddyAirCond com...

Page 10: ...rson responsible for their safety The air conditioner must be installed maintained repaired and removed by a qualified installer or qualified service person When any of these jobs is to be done ask a...

Page 11: ...y basis Setting Daily Timer 1 Press Set the ON timer 3 Press 2 Press Set the OFF timer 4 Press button during the or mark flashing During the daily timer is activating both arrows are indicated Note Ke...

Page 12: ...operation Pi Pi Pi sound but OPERATION lamp does not blink In case of ON timer or OFF timer are set AUTO RESTART OPERATION does not activate 19 20 For ECO sleep automatically control air flow and aut...

Page 13: ...EN TH 2 1 2 1 2 2 AAA 1 2 2 3 1 2 3 3 R 1 TIMER OPERATION R M h Amin m2 Amin m2 Amin M 2 5 x 0 22759 x h0 2 3 FIX AIR FLOW 1 2 1 2 TeddyAir 095 323 9555 www TeddyAirCond com...

Page 14: ...4 15 12 1 3 LCD 2 4 LCD 100 50 50 50 50 5 13 1 2 3 P 3 Reset 5 1 MODE A 2 3 AUTO LOW LOW MED MED HIGH Quiet 6 1 MODE 2 17 C 3 AUTO LOW LOW MED MED HIGH Quiet 7 1 MODE 2 9 DRY FAN ONLY 1 1 2 2 8 DRY FA...

Page 15: ...T 2 3 00 4 MODE B 00 B 1 A 2 A A 3 A 1 2 14 1 RESET 3 OPERATION 5 5 2 RESET 3 ON OFF 19 20 1 3 5 9 1 1 2 2 2 1 2 3 4 1 3 2 10 C 46 C 21 C 32 C 10 C 46 C 17 C 32 C 1 30 2 2 30 15 16 17 18 TeddyAir 095...

Page 16: ...1120650208 TeddyAir 095 323 9555 www TeddyAirCond com...

Reviews: