Taking out the power cord

3

1

2

Air inlet grille

Front panel

Earth line

Terminal
block

Cord clamp

Screw

Screw

Screw

Power cord connect cover

Power supply cord

Stripping length of the power supply cord

N

L

40 mm

10 mm

30 mm

10 mm

Earth line

 

NOTE

•  Use stranded wire only.
•  Wire type : H07RN-F or more

For the air conditioner with the power supply cord
• If the power supply cord is damaged, it must be replaced by the 

manufacturer, the service agency, or another similarly quali

fi

 ed person in 

order to avoid hazard.

•  Put the power supply cord through 

the notch.

Notch

CAUTION

1

2

3

4

1

2

3

4

 

80 mm

10 mm

10 mm

10 mm

70 mm

50 mm

Connecting 
cable

Terminal cover

Cord clamp

Terminal block

Earth line

Connecting
cable

Screw

Screw

about 1

5 cm

Earth line

Stripping length of
the connecting cable

Screw

Wiring Connection

Wiring of the connecting cable can be carried out without removing the 
front panel.

1.  Remove the air inlet grille.
 

Open the air inlet grille upward and pull it toward you.

2.  Remove the terminal cover and cord clamp.
3.  Insert the connecting cable (according to the local cords) into the pipe hole 

on the wall.

4.  Take out the connecting cable through the cable slot on the rear panel so 

that it protrudes about 15 cm from the front.

5.  Insert the connecting cable fully into the terminal block and secure it tightly 

with screws.

6.  Tightening torque : 1.2 N·m (0.12 kgf·m)
7.  Secure the connecting cable with the cord clamp.
8.  Fix the terminal cover, rear plate bushing and air inlet grille on the indoor 

unit.

     How to connect the connecting cable

•  Be sure to refer to the wiring system diagram labeled inside the front 

panel.

•  Check local electrical cords and also any speci

fi

 c wiring instructions or 

limitations. 

CAUTION

How to install the air inlet grille on the indoor 
unit

•  When attaching the air inlet grille, 

the contrary of the removed 
operation is performed.  

 NOTE

•  Use stranded wire only.
•  Wire type : H07RN-F or more

Rear right

Rear left

g

nit

t

u

c-

ei

D

til

s l

e

n

a

p t

n

orf

g

ni

g

n

a

h

C

e

s

o

ni

ar

d

n

oit

ar

a

p

er

g

ni

pi

P

Bottom left

Left

Bottom right

Right

Piping and Drain Hose Installation

*  Since dewing results in a machine trouble, make sure to insulate both con-

necting pipes. (Use polyethylene foam as insulating material.)

     

Piping and drain hose forming

1.  Die-cutting front panel slit

  Cut out the slit on the leftward or right side of the front panel for the left or 

right connection and the slit on the bottom left or right side of the front panel 
for the bottom left or right connection with a pair of nippers.

2.  Changing drain hose

 

For leftward connection, bottom-leftward connection and rearleftward con-
nection’s piping, it is necessary to change the drain hose and drain cap.

Heat insulator

Drain hose

How to remove the drain hose

•  The drain hose can be removed by removing the 

screw securing the drain hose and then pulling out 
the drain hose.

•  When removing the drain hose, be careful of any 

sharp edges of steel plate. The edges can injuries.

•  To install the drain hose, insert the drain hose 

fi

 rmly until the connection part contacts with heat 

insulator, and the secure it with original screw.

(3) Slightly open the lower part of the front panel, then pull the upper part of the 

front panel toward you to remove it from the rear plate.

(4) After removing the front panel, remove the power cord connect cover and 

the cord clamp.

(5) Connect and secure the power supply cord and secure the cord clamp and 

the power cord connect cover.

(6) Put the power supply cord through the notch.
(7) Be sure to smooth the notch with a 

fi

 le, etc.

1  2

4

 

3

 1  2

 3  4

80 mm

10 mm

10 mm

10 mm

70 mm

50 mm

Connecting 
cable

Terminal cover

Cord clamp

Terminal block

Earth line

Connecting cable

Screw

about 15 cm

Earth line

Stripping length of
the connecting cable

Screw

42NQ009

42NQ012

1110251161-EN.indd   4

1110251161-EN.indd   4

12/28/07   6:10:50 PM

12/28/07   6:10:50 PM

Summary of Contents for 38NY009-012 Series

Page 1: ...012 Series AIR CONDITIONER SPLIT TYPE INSTALLATION MANUAL ENGLISH ESPAÑOL FRANÇAIS ITALIANO DEUTSCH PORTUGUÊS POLSKI ČESKY PУCСКИЙ HRVATSKI MAGYAR TÜRKÇE NEDERLANDS ΕΛΛΗΝΙΚΑ SVENSKA SUOMI NORSK DANSK ROMÂNĂ БЪЛГАРСКИ EESTI LATVISKI SLOVENČINA SLOVENŠČINA ...

Page 2: ... 7 n Definição do interruptor do telecomando 7 n Selecção A B do telecomando 7 n Execução do Teste 7 n Definindo de Reiniciação Automática 7 PT SPIS TREŚCI ZASADY BEZPIECZEŃSTWA 1 SCHEMAT INSTALACYJNY URZĄDZENIA WEWNĘTRZNEGO I ZEWNĘTRZNEGO 2 n Dodatkowe Części Instalacyjne 2 URZĄDZENIE WEWNĘTRZNE 3 n Miejsce Instalacji 3 n Wycinanie Otworu oraz Montaż Płyty Instalacyjnej 3 n Prace Elektryczne 3 n ...

Page 3: ...IR INTO THE ROOM IF THE REFRIGERANT GAS IS HEATED BY FIRE OR SOMETHING ELSE IT CAUSES GENERATION OF POISONOUS GAS Exposure of unit to water or other moisture before installation could result in electric shock Do not store it in a wet basement or expose to rain or water After unpacking the unit examine it carefully for possible damage Do not install in a place that can increase the vibration of the...

Page 4: ...frigerant pipes separately with insulation not together 2 3 8 4 Make sure to run the drain hose sloped downward Do not allow the drain hose to get slack Cut the piping hole sloped slightly The auxiliary piping can be connected to the left rear left rear right right bottom right or bottom left Right Rear right Bottom right Rear left Bottom left Left 6 mm thick heat resisting polyethylene foam 1 Bat...

Page 5: ... installation plate A D B C 1 7 Anchor bolt holes Hook Hook Hook Pipe hole Pipe hole Installation plate Mounting screw Weight Indoor unit Thread 2 m or more from fl oor 42NQ009 42NQ012 A 35 mm 62 mm B 55 5 mm 82 5 mm C 120 mm 170 mm D 65 mm 85 mm When the installation plate is directly mounted on the wall 1 Securely fit the installation plate onto the wall by screwing it in the upper and lower par...

Page 6: ...he indoor unit When attaching the air inlet grille the contrary of the removed operation is performed NOTE Use stranded wire only Wire type H07RN F or more Rear right Rear left g n i t t u c e i D t i l s l e n a p t n o r f g n i g n a h C e s o h n i a r d n o i t a r a p e r p g n i p i P Bottom left Left Bottom right Right Piping and Drain Hose Installation Since dewing results in a machine tr...

Page 7: ...ing cable Installation plate CAUTION Indoor Unit Fixing For detaching the indoor unit from the installation plate pull the indoor unit toward you while pushing its bottom up at the specified parts Push Push Press unhook Hook Hook here 1 2 Installation plate 1 1 Pass the pipe through the hole in the wall and hook the indoor unit on the installation plate at the upper hook 2 Swing the indoor unit to...

Page 8: ...30 to 42 3 0 to 4 2 kgf m Ø12 70 mm 50 to 62 5 0 to 6 2 kgf m Evacuating After the piping has been connected to the indoor unit you can perform the air purge together at once Tightening torque of flare pipe connections Flare at indoor unit side Flare at outdoor unit side The operating pressure of R410A is higher than that of R22 approx 1 6 times It is therefore necessary to firmly tighten the flar...

Page 9: ...ctory is A To separate using of remote control for each indoor unit in case of 2 air conditioner are installed nearly Remote Control B Setup 1 Press RESET button on the indoor unit to turn the air conditioner ON 2 Point the remote control at the indoor unit When two indoor units are installed in the same room or adjacent two rooms if operating a unit two units may receive the remote control signal...