Wiring Connection

1.  Remove the valve cover from the outdoor unit.
2. Connect the connecting cable to the terminals as identi

fi

 ed with their 

respective matched numbers on the terminal block of indoor and outdoor 
unit.

3.  When connecting the connecting cable to the outdoor unit terminals, make 

a loop as shown in the installation diagram of indoor and outdoor unit to 
prevent water coming in the outdoor unit.

4. Insulate the unused cords (conductors) from any water coming in the 

outdoor unit. Proceed them so that they do not touch any electrical or metal 
parts.

100 mm

10 mm

10 mm

50 mm

1(L)

2(N)

3

4

Terminal block

Connecting cable

Terminal screw

screw

Cord clamp

Earth 
line

Earth line

     

Stripping length of the connecting cable

 

NOTE

       

: Connecting cable

•  Wire type : More than H07RN-F or 245 IEC66

CAUTION

•  Wrong wiring connection may cause some electrical parts burn out.
•  Be sure to comply with local cords on running the wire from indoor unit 

to outdoor unit (size of wire and wiring method, etc.).

•  Every wire must be connected 

fi

 rmly.

OTHERS

OTHERS

Gas Leak Test

Setting of Remote Control

Selector Switch

Remote control selector switch

Test Operation

To switch the TEST RUN (COOL) mode, 
press RESET button for 10 seconds. 
(The beeper will make a short beep.)

Auto Restart Setting

The product was shipped with Auto Restart function in the off position. 
Turn it on as required.

     

How to set the Auto Restart

Remote Control A-B Selection

3.  Push and hold [CHK] button on the Remote Control by the tip of the pencil. 

“00” will be shown on the display.

4.  Press [MODE] during pushing [CHK]. “B” will show on the display and “00” 

will disappear and the air conditioner will turn OFF. The Remote Control B 
is memorized.

Note :  1.  Repeat above step to reset Remote Control to be A.
 

 

2.  Remote Control A has not “A” display.

 

 

3.  Default setting of Remote Control from factory is A.

To separate using of remote control for each indoor unit in case of 2 air 
conditioner are installed nearly.

Remote Control B Setup.

1.  Press RESET button on the indoor unit to turn the air conditioner ON.
2.  Point the remote control at the indoor unit.

•  When two indoor units are installed in the same room or adjacent two 

rooms, if operating a unit, two units may receive the remote control 
signal simultaneously and operate. In this case, the operation can be 
preserved by setting either one indoor unit or remote control to B set-
ting. (Both are set to A setting in factory shipment.)

•  The remote control signal is not received when the settings of indoor 

unit and remote control are different.

•  There is no relation between A setting/B setting and A room/B room 

when connecting the piping and cables.

When two indoor units are installed in the separated rooms, it is not 
necessary to change the selector switches.

• Check the 

fl

 are nut connections 

for the gas leak with a gas leak 
detector or soap water.

This product is designed so that, after a power failure, it can restart automati-
cally in the same operating mode as before the power failure.

•  Press and hold the RESET button for about 3 seconds. After 3 seconds, the 

electronic beeper makes three short beeps to tell you the Auto Restart has 
been selected.

•  To cancel the Auto Restart, follow the steps described in the section Auto 

Restart Function of the owner’s manual.

RESET button

Check places for
the indoor unit.

Electric parts 
cover

Check places for the outdoor unit.

Valve cover

Information

MODE

AUTO
COOL

FAN

TEMP.

TEMP.

AUTO
QUIET

HEAT

DRY

B

B

•  Open the valve stem all the way out, but do not try to open it beyond the stopper.
•  Securely tighten the valve stem cap with torque in the following table:

     Packed valve handling precautions

m

m

 

4

The hexagon wrench
is required.

Gas side
(Ø12.70 mm)

50 to 62 N·m
(5.0 to 6.2 kgf·m)

Gas side
(Ø9.52 mm)

30 to 42 N·m
(3.0 to 4.2 kgf·m)

Liquid side
(Ø6.35 mm)

16 to 18 N·m
(1.6 to 1.8 kgf·m)

Service port

9 to 10 N·m
(0.9 to 1.0 kgf·m)

1110251161-EN.indd   7

1110251161-EN.indd   7

12/28/07   6:10:55 PM

12/28/07   6:10:55 PM

Summary of Contents for 38NY009-012 Series

Page 1: ...012 Series AIR CONDITIONER SPLIT TYPE INSTALLATION MANUAL ENGLISH ESPAÑOL FRANÇAIS ITALIANO DEUTSCH PORTUGUÊS POLSKI ČESKY PУCСКИЙ HRVATSKI MAGYAR TÜRKÇE NEDERLANDS ΕΛΛΗΝΙΚΑ SVENSKA SUOMI NORSK DANSK ROMÂNĂ БЪЛГАРСКИ EESTI LATVISKI SLOVENČINA SLOVENŠČINA ...

Page 2: ... 7 n Definição do interruptor do telecomando 7 n Selecção A B do telecomando 7 n Execução do Teste 7 n Definindo de Reiniciação Automática 7 PT SPIS TREŚCI ZASADY BEZPIECZEŃSTWA 1 SCHEMAT INSTALACYJNY URZĄDZENIA WEWNĘTRZNEGO I ZEWNĘTRZNEGO 2 n Dodatkowe Części Instalacyjne 2 URZĄDZENIE WEWNĘTRZNE 3 n Miejsce Instalacji 3 n Wycinanie Otworu oraz Montaż Płyty Instalacyjnej 3 n Prace Elektryczne 3 n ...

Page 3: ...IR INTO THE ROOM IF THE REFRIGERANT GAS IS HEATED BY FIRE OR SOMETHING ELSE IT CAUSES GENERATION OF POISONOUS GAS Exposure of unit to water or other moisture before installation could result in electric shock Do not store it in a wet basement or expose to rain or water After unpacking the unit examine it carefully for possible damage Do not install in a place that can increase the vibration of the...

Page 4: ...frigerant pipes separately with insulation not together 2 3 8 4 Make sure to run the drain hose sloped downward Do not allow the drain hose to get slack Cut the piping hole sloped slightly The auxiliary piping can be connected to the left rear left rear right right bottom right or bottom left Right Rear right Bottom right Rear left Bottom left Left 6 mm thick heat resisting polyethylene foam 1 Bat...

Page 5: ... installation plate A D B C 1 7 Anchor bolt holes Hook Hook Hook Pipe hole Pipe hole Installation plate Mounting screw Weight Indoor unit Thread 2 m or more from fl oor 42NQ009 42NQ012 A 35 mm 62 mm B 55 5 mm 82 5 mm C 120 mm 170 mm D 65 mm 85 mm When the installation plate is directly mounted on the wall 1 Securely fit the installation plate onto the wall by screwing it in the upper and lower par...

Page 6: ...he indoor unit When attaching the air inlet grille the contrary of the removed operation is performed NOTE Use stranded wire only Wire type H07RN F or more Rear right Rear left g n i t t u c e i D t i l s l e n a p t n o r f g n i g n a h C e s o h n i a r d n o i t a r a p e r p g n i p i P Bottom left Left Bottom right Right Piping and Drain Hose Installation Since dewing results in a machine tr...

Page 7: ...ing cable Installation plate CAUTION Indoor Unit Fixing For detaching the indoor unit from the installation plate pull the indoor unit toward you while pushing its bottom up at the specified parts Push Push Press unhook Hook Hook here 1 2 Installation plate 1 1 Pass the pipe through the hole in the wall and hook the indoor unit on the installation plate at the upper hook 2 Swing the indoor unit to...

Page 8: ...30 to 42 3 0 to 4 2 kgf m Ø12 70 mm 50 to 62 5 0 to 6 2 kgf m Evacuating After the piping has been connected to the indoor unit you can perform the air purge together at once Tightening torque of flare pipe connections Flare at indoor unit side Flare at outdoor unit side The operating pressure of R410A is higher than that of R22 approx 1 6 times It is therefore necessary to firmly tighten the flar...

Page 9: ...ctory is A To separate using of remote control for each indoor unit in case of 2 air conditioner are installed nearly Remote Control B Setup 1 Press RESET button on the indoor unit to turn the air conditioner ON 2 Point the remote control at the indoor unit When two indoor units are installed in the same room or adjacent two rooms if operating a unit two units may receive the remote control signal...

Reviews: