62-11785
7–66
05005
BAD F9 FUSE
• ACTIVATION: CCB Fuse Alarm; Feedback from CCB indicates fuse is missing or blown. Signal must be
present for at least 3 seconds.
• UNIT CONTROL: Shutdown and Alarm.
• RESET CONDITION: Replace or fix fuse issue.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (See Note 1 in
Section.) Operate the unit through the appropriate modes to see if any active
alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
Check Fuse F9
a. Visually check fuse. Verify correct fuse, check fuse holder for damage, see
. Replace
fuse as required. Clear alarms, restart and check for repeat alarm(s).
b. Check voltage. Check voltage through the fuse, if fuse is blown, replace it.
c. Check wiring. Verify there is no physical damage to harness, and no damage, moisture, or
corrosion in connectors.
05006
POWER ENABLE RELAY FUSE ALARM
• ACTIVATION: Fuses 9 and 10 must be in a failed state in order to trigger the Power Enable Relay (PER)
Fuse Alarm.
• UNIT CONTROL: Shutdown and Alarm.
• RESET CONDITION: Fuses are not in a failed state.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (See Note 1 in
Section.) Operate the unit through the appropriate modes to see if any active
alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1.
Check Fuse F5
a. Visually check fuse. Verify correct fuse, and check fuse holder for damage, see
Replace fuse as required. Clear alarms, restart and check for repeat alarm(s).
b. Check voltage. Check voltage through the fuse, if fuse is blown, replace it.
c. Check wiring. Verify there is no physical damage to harness, and no damage, moisture, or
corrosion in connectors.
2.
Check Fuse F9 and F10
a. Visually check fuses. Verify correct fuse, and check fuse holder for damage, see
Replace fuse as required. Clear alarms, restart and check for repeat alarm(s).
b. Check voltage. Check voltage through the fuse, if fuse is blown, replace it.
c. Check wiring. Verify there is no physical damage to harness, and no damage, moisture, or
corrosion in connectors.
Summary of Contents for VECTOR 8100
Page 2: ......
Page 4: ......
Page 12: ...62 11785 viii ...
Page 16: ...62 11640 12 ...
Page 18: ...62 11785 ...
Page 24: ...62 11785 1 6 1 3 SAFETY DECALS ...
Page 25: ...1 7 62 11785 ...
Page 26: ...62 11785 1 8 ...
Page 27: ...1 9 62 11785 ...
Page 28: ...62 11785 1 10 ...
Page 30: ...62 11785 ...
Page 50: ...62 11785 ...
Page 82: ...62 11785 ...
Page 96: ...62 11785 4 14 ...
Page 98: ...62 11785 ...
Page 129: ...5 31 62 11785 ...
Page 130: ...62 11785 5 32 ...
Page 134: ...62 11785 6 4 ...
Page 138: ...62 11785 ...
Page 230: ...62 11785 ...
Page 271: ...8 41 62 11785 ...
Page 272: ...62 11785 8 42 ...
Page 274: ...62 11785 ...
Page 286: ......
Page 287: ......
Page 288: ...62 11785 10 8 ...
Page 292: ......
Page 293: ......