28
Wide Bank 28 DS3 - Release 2.4
T1/E1 Protection and Revertive Configuration
2. Retrieve Current T1/E1 Condition
RTRV-COND-T1:tid::ctag;
RTRV-COND-E1:tid::ctag;
Example:
RTRV-COND-T1:tid:DS1-1:ctag;
Response:
tid 2001-08-04 05:05:51
M ctag COMPLD
"DS1-01,T1:INHAUTORSTEQPT,NSA,,,,,,\"DS1 Revertive Off\""
"DS1-01,T1:INHSWPR,NSA,,,,,,\"DS1 Facility Protection Not Enabled\""
;
3. Determine T1/E1 Protection and Revertive Choices
If DS1/E1 condition is
Your choice is
T1:IHNSWPR
E1:IHNSWPR
Allow DS1/E1 automatic protection switching:
ALW-SWTOWKG-T1:tid:ALL:ctag;
ALW-SWTOWKG-E1:tid:ALL:ctag;
(if these do not appear)
T1:IHNSWPR
E1:IHNSWPR
Inhibit DS1/E1 automatic protection switching:
ALW-SWTOWKG-T1:tid:ALL:ctag;
ALW-SWTOWKG-E1:tid:ALL:ctag;
Note: The above commands will also reset a revertive lockout and
allow any circuits locked onto the spare card to switch back to their
home card if the home circuit is healthy.
T1:INHAUTORSTEQPT
E1:INHAUTORSTEQPT
Allow DS1/E1 revertive switching from spare to home circuit:
ALW-AUTORST:tid::ctag::DS1EQPT;
ALW-AUTORST:tid::ctag::E1EQPT;
(if these do not appear)
T1:INHAUTORSTEQPT
E1:INHAUTORSTEQPT
Inhibit DS1/E1 revertive switching:
INH-AUTORST:tid::ctag::DS1EQPT;
INH-AUTORST:tid::ctag::E1EQPT;
If T1:PROTNA or E1:PROTNA appears,
protection is not available because the
unit is not equipped with a spare card.