T1/E1 Equipment Status Values
Equipment
Status
Description
DS1/E1 Card
Active
DS1/E1 card is installed and active, but individual DS1/E1
circuits may have failed and be on Spare card
Not Present
DS1/E1 card is not installed
MSO Active
DS1/E1 MSO card (relay and electronics) is installed and
active, but individual DS1/E1 circuits may have failed and
be on Spare card
MSO Relay Only
Active on Spare
DS1/E1 MSO relay card is installed, but electronics card is
missing. Circuits have been switched to Spare card.
MSO Relay Only
Not Active
DS1/E1 MSO relay card is installed, but electronics card is
missing. Circuits have been switched to Spare card.
MSO Relay Only
Conflict On Spare
DS1/E1 MSO relay card is installed, but electronics card is
missing. Multiple MSO card removals prevent switching
circuits to Spare.
MSO Relay Only
Spare Not Present
DS1/E1 MSO relay card is installed, but electronics card is
missing. Circuits cannot be switched because Spare card is
not installed.
Wrong Card for
Mode
System mode is set to DS1 when E1 card is installed, or
vice versa. Status applies to both MSO and non-MSO card
types.
DS1/E1 Card
Spare
Active
DS1/E1 card is installed and active, but individual DS1/E1
circuits may have failed
Not Present
DS1/E1 card is not installed
MSO Active
DS1/E1 MSO card (relay and electronics) is installed and
active, but individual DS1/E1 circuits may have failed
MSO Relay Only
Spare Not Present
DS1/E1 MSO relay card is installed, but electronics card is
missing. Circuits cannot be switched without spare
electronics.
Conflict
Multiple MSO card removals prevent switching circuits to
Spare
Wrong Card for
Mode
System mode is set to DS1 when E1 card is installed, or
vice versa. Status applies to both MSO and non-MSO card
types.