26
Wide Bank 28 DS3 - Release 2.4
T1/E1 Protection and Revertive Configuration
T1/E1 Protection and Revertive Configuration
The following steps show how to retrieve the current T1/E1 equipment configuration and condition,
and how to change the T1/E1 protection and revertive properties.
1. Retrieve Current T1/E1 Equipment Configuration
This will show the status of the DS1/E1 spare card and whether the unit can provide circuit protection.
RTRV-EQPT:tid:[ALL]:ctag;
Example:
RTRV-EQPT:tid:ALL:ctag;
Response:
tid 2001-08-04 05:08:45
M ctag COMPLD
"DS3-A:ACTIVE,2.40.0"
"DS3-B:STANDBY,2.40.0"
"DS1-CARD-1:ACTIVE,"
"DS1-CARD-2:ACTIVE,"
"DS1-CARD-3:ACTIVE,"
"DS1-CARD-4:ACTIVE,"
"DS1-CARD-5:ACTIVE,"
"DS1-CARD-6:ACTIVE,"
"DS1-CARD-7:ACTIVE,"
"DS1-CARD-SPARE:ACTIVE,"
;
Status of spare card.
Unit can provide low-speed protection if
spare card is ACTIVE or MSO ACTIVE.
Status of working cards