3-32
BROADway - Release 4.00
Configuration
Upgrading System Software
Rolling Back a Software Update
Should you want to reload a previous software version into the
BROAD
way system, the process is the
same as the one previously outlined, but with one exception. When FTPing the system software file to
the
BROAD
way unit, save the file to the /VDISK folder rather than the /FLASH folder. From release
3.08 onwards, software upgrades operate out of working RAM rather than Flash memory. For example:
c:\>ftp 192.168.5.60
Connected to 192.168.5.60.
220 VxWorks (5.4.2) FTP server ready
User (192.168.5.60:(none)): ADMIN
331 Password required
Password:
230 User logged in
ftp> cd /VDISK
250 Changed directory to "/VDISK"
ftp> bin
200 Type set to I, binary mode
ftp> put c:\temp\bw304.zip
200 Port set okay
150 Opening BINARY mode data connection
226 Transfer complete
ftp: 4664234 bytes sent in 124.73Seconds 37.40Kbytes/sec.
ftp> bye
221 Bye...see you later
Upgrading the Boot ROM
Occasionally, system software releases will be accompanied by a firmware update to the Boot ROM on
the NSP101 module. The minimum boot ROM revision required for system release 3.08 is version 1.6.
The current revision number is available on the startup screen during the
BROAD
way boot cycle or
through the use of the
exec-sys
TL1 command:
NSP1> exec-sys::nsp:1234::vers;
BROADway version: 3.04
PS version: 3.04
DATABASE version: 2.1
BSP Version : 1.60
value = 26 = 0x1a
2003-04-24 10:19:56
M 1234 COMPLD
NSP-1,
;
Summary of Contents for BROADway System 770-0125-AB
Page 1: ...BROADway INSTALLATION MANUAL Part Number 770 0125 AB Product Release 4 00 March 2004 ...
Page 10: ...x BROADway Release 4 00 Preface Third Party Software Notices ...
Page 14: ...xiv BROADway Release 4 00 Table of Contents ...
Page 15: ...CHAPTER 1 Introduction In This Chapter Overview ...
Page 59: ...BROADway Release 4 00 3 11 Configuration Logging In With the Web Browser Interface GUI ...