BROADway - Release 4.00
2-21
Installation
Installing the BSP200 Line Interface Card
Installing the BSP200 Line Interface Card
BROAD
way supports up to four BSP200 single port DS3/mapper line interface cards installed in
positions BSP-1, BSP-2, BSP-3 and BSP-4. If you plan to support redundant BSP operation, you should
preferably install the redundant BSP module in BSP-4. When cabling to other DS3 equipment in an
office environment. Follow the design rules for the distance between DS3 terminal equipment and
DSX-3 bays and inter-bay patch panels; DS3 signals can be very sensitive to incorrectly wired
segments.
Insert the BSP200 card into the chassis. Open the ejector tabs and slide the card into its proper slot until
you feel resistance, then push to close the ejector tabs into their locking position against the metal rails.
Check that the card is firmly in place by applying pressure to the ejector tabs to seat the card fully into
the chassis.
WARNING!
W
HEN
INSTALLING
OR
REPLACING
BROAD
WAY
HARDWARE
,
ALWAYS
ADHERE
TO
GOOD
PRACTICE
WITH
RESPECT
TO
ESD
PROCEDURES
—
USE
A
REGULARLY
AND
PROPERLY
TESTED
GROUNDING
STRAP
.
CKIN-1
NIP TX1
NIP TX2
TX2
TX1
TX3
TX4
NIP RX1
NIP RX2
RX3
RX1
RX2
RX4
ALARMS
ACO
SCP-2
ETH-1
CKIN-2
ETH-2
SCP-1
BSP-4
BSP-3
BSP-2
BSP-1
BSP200 line terminations
Summary of Contents for BROADway System 770-0125-AB
Page 1: ...BROADway INSTALLATION MANUAL Part Number 770 0125 AB Product Release 4 00 March 2004 ...
Page 10: ...x BROADway Release 4 00 Preface Third Party Software Notices ...
Page 14: ...xiv BROADway Release 4 00 Table of Contents ...
Page 15: ...CHAPTER 1 Introduction In This Chapter Overview ...
Page 59: ...BROADway Release 4 00 3 11 Configuration Logging In With the Web Browser Interface GUI ...