40
Defect
Solution
Advice
The sowing rate is too low
-
Common seed: Microdosage is
activated
-
Fine seed: The cells are dirty
-
The cleaning brush is defective
The ploughshare pipe is
obstructed with seed
-
The turbine adjustment flap is set
to fixed seed for common seed.
-
The diffusers are obstructed with
soil
-
The turbine speed is too low
The sowing is too deep
-
Lower the depth gauge wheels
The comb harrow is working too
deeply
-
The pressure is too high.
-
The depth was incorrectly set.
The comb harrow is clogged
-
The angle of the comb harrow
was set too steep
6.4 Screw tightening torque
Threading
Tightening torque according to the quality rating of
the screws and nuts (in Nm)
8.8
10.9
12.9
M8
24
33
40
M10
47
65
79
M12
81
114
136
M14
128
181
217
M16
197
277
333
M18
275
386
463
M20
385
541
649
M22
518
728
874
M24
665
935
1120