33
and runs at the programmed CALIBRATION speed to distribute the correct
quantity of product, and then stops.
NOTE: If a manual calibration button is used for the CALIBRATION, the calibration
procedure will start (fig. 13).
4.
Weight the product obtained in the bucket, and enter this value (fig. 14). Then
press CONFIRM to confirm.
Figure 12
5.
Press CONFIRM again, and the console recalculates and displays the new
CALIBRATION factor in kg/rev, the error %, and the maximum forward speed
allowed calculated according to the application dose that is set for the product
(fig.15).
Figure 15
6.
Press CONFIRM again to confirm and store the new calibration factor, or press
ESC to go back to the SETTINGS screen.
The PARTIAL counter should be reset before starting to sow. This will allow you,
after having sowed a portion of the plot, to quantify any error in the calibration
factor by comparing the theoretical quantity of product sowed with the actual
quantity sowed that is known (an entire big bag for example).
You can then accurately adjust the calibration factor, is needed (see section
2.5.2).
NOTE: Systems mounted on an 'Accord' type dispenser.