13
FlOW TIME ADJUsTMENT
how to adjust the flow time in your battery and mains options
1) open the piezo cap using the provided 2 mm allen key.
2) disconnect the power supply (batteries or transformer).
3) While the power source is disconnected, verify that the solenoid valve is installed
and touch the piezo cap twice.
4) then, reconnect the power supply.
5) the indicator light (LEd) on the back
of the Piezo cap will start blinking. after
a few blinks the LEd will give a steady
red light. touch the Piezo cap when the
steady red light is still on to enter into the
adjusting mode. When done correctly, the
light will stop blinking.
note:
If you will not press at the indicated
area, the previous adjustment will remain.
6) By touching the Piezo cap the new flow
time will be programmed. In adjusting
mode level 1, each touch increases the
flow time by 1 second with a maximum of
10 seconds. You will see the LEd blinking every time that a new step is performed.
7) If your desired flow time is within 10 seconds, no other adjusting levels are needed
and you can stop pressing the Piezo cap. the LEd will blink 2 times, then 3 times and
after 4 times you will leave the adjusting mode. the mixer or tap is now adjusted to
the desired flow time.
Example 3: You wish to adjust the flow time to 60 seconds.
at level 1 perform 10 steps of 1 second (you will get 10 seconds). total: 10 seconds
Go to level 2 and perform 10 steps of 2 seconds (you will get 20 seconds). total: 30
seconds)
Go to level 3 and perform 2 steps of 15 seconds (you will get 30 seconds). total: 60
seconds.