FlOW TIME ADJUsTMENT
level 1 level 2 level 3 out of adjusting mode
no. of steps
Seconds to be increased by
touching once
adjustment level indicator
10 steps 10 steps 2 steps
1 second 2 seconds 15 seconds
after
entering into
adjusting
mode level 1
is reached
Indicator
light blinks
twice
Indicator
light blinks
3 times
Indicator light blinks 4 times
adjustment levels
the flow time is programmable on site. If necessary, the default flow time of 8
seconds can be adjusted to any value between 1 to 60 seconds. the adjustment
mechanism is composed of 3 adjustment levels for changing the flow time. an
indicator light (LEd) will guide you from one level to the other.
the following table shows the number of steps in each level, the duration of each
step and how to recognize in what adjusting level you are.
the following examples show how to manage the adjustment levels:
Example 1: You wish to adjust the flow time to 20 seconds.
at level 1 perform 3 steps of 1 second (you will get 3 seconds). total: 3 seconds
Go to level 2 and perform 1 step of 2 seconds (you will get 2 seconds). total: 5
seconds)
Go to level 3 and perform 1 step of 15 seconds (you will get 15 seconds). total: 20
seconds.
Example 2: You wish to adjust the flow time to 45 seconds.
at level 1 perform 1 step of 1 second (you will get 1 second). total: 1 second
Go to level 2 and perform 7 steps of 2 seconds (you will get 14 seconds). total: 15
seconds)
Go to level 3 and perform 2 steps of 15 seconds (you will get 30 seconds). total: 45
seconds.