16
1.5 Refrigerants
All 06CC compressors built after 2099J are approved for
R-22, R-404A, R-407A, and R-507 except compressors
in the 16 to 37 cfm range. Compressors in this size range
cannot be used with R-404A, R-407A and R-507 prior to
serial number 2099J- - - - without installing a retrofit com-
pressor valve plate (part number 06CY660-002) kit.
1.6 Electrical Data Table
LEGEND
NOTES:
1.
RLA (rated load amps) value shown for new high-efficiency mod-
els is MCC ÷ 1.56 = RLA. Use this recommended (and minimum)
RLA value to determine nameplate stamping, minimum contactor
sizing and wire sizing.
2.
Compressor operating amps at any specific condition can only be
determined from a performance curve.
3.
RLA values for 06D compressor protected by calibrated circuit
breaker will depend must-trip value of circuit breaker.
4.
Ohm values shown for resistance are approximate and shown for
reference only. Motors from different vendors and motors of differ-
ent efficiencies can differ up to 15% from data shown.
Allowable Operating Range
COMPRESSOR MOTOR DATA
Compressor
Model
Max
kW
HP
Electrical Data
Overload Carlyle
Part No.
Part No.
T.I. No.
Volts
MCC
RLA
LRA
Motor Winding
Resistance
(Ohms)
06CC016J101
D101
G101
6.25
5
575
208/230
460
10.8
27.0
13.5
6.9
17.3
8.7
40
100
50
3.3
0.54
2.1
HN69GZ032
HN69GZ024
HN69GZ014
8347A23-42
8347A23-63
8347A23-53
06CC017J101
D101
G101
6.25
5
575
208/230
460
10.8
27.0
13.5
6.9
17.3
8.7
40
100
50
3.3
0.54
2.3
HN69GZ032
HN69GZ024
HN69GZ014
8347A23-42
8347A23-63
8347A23-53
06CC018J101
D101
G101
6.25
5
575
208/230
460
10.8
27.0
13.5
6.9
17.3
8.7
40
100
50
3.3
0.54
2.1
HN69GZ032
HN69GZ024
HN69GZ014
8347A23-42
8347A23-63
8347A23-53
06CC124J101
D101
G101
9.18
6.5
575
208/230
460
13.2
33.0
16.5
8.5
21.2
10.6
64
160
80
2.6
0.42
1.7
HN69GZ037
HN69GZ214
HN69GZ038
8347A23-40
8348A23-9
8347A23-18
06CC125J101
D101
G101
9.18
6.5
575
208/230
460
13.2
33.0
16.5
8.5
21.2
10.6
64
160
80
2.6
0.42
1.7
HN69GZ037
HN69GZ214
HN69GZ038
8347A23-40
8348A23-9
8347A23-18
06CC228J101
D101
G101
12.8
7.5
575
208/230
460
16.7
41.6
20.9
10.2
26.7
13.4
79
198
99
2.0
0.31
1.3
HN69GZ004
HN69GZ306
HN69GZ010
8347A23-19
8347B23-13
8347A23-29
06CC337J101
D101
G101
16.5
10
575
208/230
460
18.8
46.5
23.3
12.1
29.8
14.9
91
228
114
1.7
0.26
1.0
HN69GZ025
HN69GZ309
HN69GZ024
8347A23-31
8347B23-11
8347A23-63
LRA —
Locked Rotor Amps
MCC —
Maximum Continuous Current
RLA —
Rated Load Amps
TI
—
Texas Instruments
NOMINAL
VOLTAGE
MAXIMUM
VOLTAGE
MINIMUM
VOLTAGE
206/230
254
187
575
661
518
400 (50 Hz)
460
342
200 (50 Hz)
230
180