10.11.98
Introduction
INSTALLATION INSTRUCTIONS
Installation shall be performed by competent personnel and comply with current
national wiring regulations.
VOLTAGE ADJUSTMENT and/or correct FUSE SELECTION may be required on
individual subsystems. This should be carried out before proceeding with system
installation and wiring.
THIS EQUIPMENT MUST BE EARTHED.
Equipment is designed for connection to single phase supplies with the Neutral
conductor at earth potential - category TN - and is fitted with a protective fuse in
the Live conductor only. It is not designed for use with Phase (Live) and Neutral
connections reversed or where the Neutral conductor is not at earth potential (TT
OR IT SUPPLIES).
An EXTERNAL DISCONNECT DEVICE is required for this equipment which
must be installed according to current wiring regulations. A detachable power
cord, if fitted to this equipment, is a suitable disconnect device, otherwise an
approved disconnect switch is required whose rating is defined in the product
specification and on the equipment itself.
An EXTERNAL OVER-CURRENT PROTECTION DEVICE is required to protect
the wiring to this equipment which must be installed according to current wiring
regulations. The fusing or breaking current are defined in the product
specification. In certain countries this function is supplied by use of a fused plug.
Where equipment is intended for PERMANENT INSTALLATION, cables will be
coded with either of the following colour schemes:
Live:
Brown
Black
Neutral:
Blue
White
Earth:
Yellow/Green
Green
Some equipment utilises MULTIPLE POWER SOURCES. This is clearly marked
on the equipment. Finished installation must also be clearly marked to ensure
that all sources of power are removed before servicing begins.
Summary of Contents for Solid State Logic SL 9000 J Series
Page 1: ...82S6Q9K010B SL 9000 Series Installation Guide V 2 1 2 7 98...
Page 2: ...12 3 97...
Page 3: ...Solid State Logic SL 9000 Series Installation Guide V2 1 2 7 98...
Page 8: ...i8 12 3 97 SL 9000 J Series Console Installation Guide...
Page 9: ...Solid State Logic SL 9000 J Total Studio System Installation Guide 82S6Q9K010B...
Page 44: ...36 18 9 97 SL 9000 J Series Console Installation Guide...