![CARLO GAVAZZI RSWT Series Manual Download Page 16](http://html1.mh-extra.com/html/carlo-gavazzi/rswt-series/rswt-series_manual_2558648016.webp)
16
RSWT
Carlo Gavazzi LTD
RSWT DS ENG
17/05/2018
Performance
Current / power ratings: kW and HP @ 40°C
Model
IEC Rated
Current
220 - 240 VAC
380 - 415 VAC
440 - 480 VAC
550 - 600 VAC
RSWT..12
12 Arms
3 kW / 3 HP
5.5 kW / 5 HP
5.5 kW / 7.5 HP
9 kW / 10 HP
RSWT..16
16 Arms
4 kW / 5 HP
7.5 kW / 7.5 HP
9 kW / 10 HP
11 kW / 15 HP
RSWT..25
25 Arms
5.5 kW / 7.5 HP
11 kW / 10 HP
11 kW / 15 HP
20 kW/ 20 HP
RSWT..32
32 Arms
9 kW / 10 HP
15 kW / 15 HP
18.5 kW / 20 HP
22 kW/ 30 HP
RSWT..37
37 Arms
9 kW / 10 HP
20 kW / 20 HP
22 kW / 25 HP
30 kW/ 30 HP
RSWT..45
45 Arms
11 kW / 15 HP
22 kW/ 25 HP
22 kW/ 30 HP
37 kW/ 40 HP
RSWT..55
55 Arms
15 kW / 20 HP
30 kW / 30 HP
30 kW / 40 HP
45 kW / 50 HP
RSWT..70
70 Arms
20 kW / 25 HP
37 kW / 40 HP
45 kW / 50 HP
55 kW / 60 HP
RSWT..90
90 Arms
22 kW / 30 HP
45 kW / 50 HP
55 kW / 60 HP
75 kW / 75 HP
Ratings:
kW rating according to: IEC/EN 60947-4-2
HP rating according to: UL508
Starts per hour
The table below indicates the maximum number of starts/hr that can be done by the different RSWT models at
different operating currents with a surrounding temperature of 40°C.
Model
Operational current
6 Arms
12 Arms
16 Arms
25 Arms
32 Arms
37 Arms
45 Arms
RSWT..12
45
20
-
-
-
-
-
RSWT..16
60
25
20
-
-
-
-
RSWT..25
100
50
35
20
-
-
-
RSWT..32
-
65
45
25
20
-
-
RSWT..37
-
80
55
30
24
20
-
RSWT..45
-
100
75
40
30
25
20
Model
Operational current
25 Arms
32 Arms
37 Arms
45 Arms
55 Arms
70 Arms
90 Arms
RSWT..55
50
40
30
25
20
-
-
RSWT..70
70
50
45
35
25
20
-
RSWT..90
95
70
60
45
35
10
20