The motion zone can be blanked in 7 steps for all three directions using the 3
rotary switches “Left”, “Center” or “Right” (see fig . 9) .
Fig . 9
Blanking center
Blanking left
Blanking right
After adjusting
the zones it must be verified that the motion zone is active in the wanted area
by a ”walking test” .
Blanking of Motion Zone
ON
DIP
1 2 3 4 5 6
MIN MAX
TEST HIGH
SAFE NO
MOTION NO
UNI-DIR.
LOW
NC
NC
BI-DIR.
5 MIN
1 MIN
30 SEC
10 SEC
SENSITIVITY
PRESENCE
TIME
MIN MAX
MIN MAX
MIN MAX
MOTION AREA ADJUSTMMENT
CENTER
LEFT
RIGHT
TEACH-IN
TÜV NOT TÜV
The sensitivity rotary switch allows settings in 7 steps . In order to select the
right compromize between sensitivity and immunity .
• A normal setting would be 3-5 (Normal light condition) (4 is default) .
• For indoor applications with light shadows, setting at 6-7 can be used .
• In outdoor conditions with strong light, rain or snow, a setting from 1-2
could be selected (strong light with heavy shadows) .
Adjust Sensitivity
ON
DIP
1 2 3 4 5 6
MIN MAX
TEST HIGH
SAFE NO
MOTION NO
UNI-DIR.
LOW
NC
NC
BI-DIR.
5 MIN
1 MIN
30 SEC
10 SEC
SENSITIVITY
PRESENCE
TIME
MIN MAX
MIN MAX
MIN MAX
MOTION AREA ADJUSTMMENT
CENTER
LEFT
RIGHT
TEACH-IN
TÜV NOT TÜV
1
2
3
4
5
6
7
Sensitivity
Immunity
Max Sensitivity
Recommended settings
Max Immunity
Max
Min
Motion zone
Presence zone