Carlin EZ-1 Manual Supplement Download Page 14

Carlin part number MNEZ123 Rev. 01/12/10

– 13 –

Model EZ-1/2/3 oil burners — Instruction manual

Two-line fuel system

Figure 12 

Two-line fuel system maximum lengths for 3/8” and 

Table 4 

1/2” OD copper tubing distribution. Use only for 

burners equipped with Suntec fuel units. See fuel 

unit data sheet for any other fuel unit.

Perform checkout procedures

Verify before starting burner:

  Should overheating or an emergency occur, immediately:

 

•  Shut off oil supply line valve.

 

•  Under some circumstances power should remain on for 
water pumps or blowers. Determine proper response before 
attempting start-up.

 

•  If burner fails ignition on several attempts, use burner 
blower to purge appliance chamber before restart.

Checklist

❏ 

Burner/appliance installed per appliance instruction manual?

❏ 

Burner nozzle and head positioning bar verified against Table 1, page 4, 
or appliance manufacturer’s instructions?

❏ 

Burner/appliance installed per all applicable codes?

❏ 

Installation site has adequate combustion/ventilation air openings and 
vent system?

❏ 

Fuel supply line in good condition and sized/designed correctly?

❏ 

Oil tank has oil and oil line valves are open.

❏ 

Wiring installed per burner/appliance instructions?

❏ 

Burner, appliance and all components inspected and in good condi-
tion?

3.  Prepare burner 

(continued)

Two-line fuel system requirements

See Figure 12 and Table 4. Use Table 4 only for burners equipped with 
Suntec fuel units. For burners using other fuel units, read the fuel unit 
manufacturer’s data sheet to determine maximum lengths and lifts.
The standard burner fuel unit is a single-stage, 3450-RPM oil pump. Use 
this  fuel  unit  only  on  two-line  oil  systems  that  do  not  exceed  the  total 
tubing lengths allowed in Table 4 (for Suntec fule units only). For longer 
systems (or where lift exceeds 10 feet), replace the one-stage fuel unit 
with a two-stage unit.
Always size fuel lines using an oil flow rate based on the fuel unit gearset ca-
pacity, not the burner firing rate. See fuel unit data sheet for information.

  Install the fuel unit bypass plug when connecting to a two-line 

system. The plug is shipped in a bag attached to the fuel unit, 
along with a fuel unit data sheet.

Summary of Contents for EZ-1

Page 1: ...in severe personal injury death or substantial property damage Boiler model Burner model Primary control Ignitor Fuel unit Oil valve Motor Air tube welded flange Comb head Air band Carlin model Prepur...

Page 2: ...ly stated otherwise this manual must be used only by a quali fied service technician Failure to comply with this or other requirements in this manual could result in severe personal injury death or su...

Page 3: ...nd perform the training outlined below Train the user To properly operate the burner appliance per this manual and the appliance instructions see User s information To keep this manual at or near the...

Page 4: ...age 4 for an initial nozzle selection for the application Specific applications may require testing more than one nozzle to obtain both clean combustion and a good match of flame shape to the combusti...

Page 5: ...PH Flame length needed 1 50 1 65 to 1 75 2 00 2 25 2 00 2 25 2 50 Nozzle rating GPH Nozzle rating GPH 1 50 1 65 1 75 2 00 2 25 2 00 2 25 2 50 Delavan Hollow 60 A Delavan Hollow 60 A Medium Solid 60 B...

Page 6: ...t or 50 cubic feet per MBH of all appliances in the room Example For each 1 GPH oil input the room must have 7 000 cubic feet 875 square feet with an 8 foot ceiling height Minimum combustion ventilati...

Page 7: ...and any associated instructions in the Burner Cover or 97406 Air Intake System instructions Even if using an optional air intake system make sure the space provides enough ventilation to prevent over...

Page 8: ...ashpit area or fill ashpit with sand up to 2 inches above the mud ring of a boiler firing through the door Install a lightweight refractory liner on the target wall as in Table 3 Figure C Make sure t...

Page 9: ...ion chamber Universal adjustable flange burners 1 Verify the flange mounting slots line up with the appliance bolts See Figure 1 2 Slip the adjustable flange onto the air tube 3 Measure the distance f...

Page 10: ...For pressur ized firing you must obtain a burner with a welded flange designed for use with the specific appliance Failure to comply could result in severe personal injury death or substantial proper...

Page 11: ...ndition 9 Inspect the ignitor contact clips Clean or replace if necessary to ensure reliable contact with the electrodes Inserting removing combustion head assembly Figure 5 3 Prepare burner Install n...

Page 12: ...GPH 7 options 0 50 0 60 0 65 0 75 0 85 1 00 1 10 1 25 1 10 1 25 1 35 1 50 1 65 EZ 2 EZ 2 HP 1 50 2 25 GPH 4 options 1 50 1 65 1 75 2 00 2 25 EZ 3 EZ 3 HP 2 00 2 50 GPH 3 options 2 00 2 25 2 50 Adjust...

Page 13: ...oil system Operating with the plug in place on a one line system will damage the fuel unit and could lead to oil leakage and fire hazard If the fuel line or fuel supply is above burner never exceed 3...

Page 14: ...n ventilation air openings and vent system Fuel supply line in good condition and sized designed correctly Oil tank has oil and oil line valves are open Wiring installed per burner appliance instructi...

Page 15: ...h is properly fused for the load To start burner Do not start the burner if the combustion chamber contains oil or oil vapor 1 Turn service switch OFF 2 Perform inspections and checkouts on pages 14 a...

Page 16: ...Carlin part number MNEZ123 Rev 01 12 10 15 Model EZ 1 2 3 oil burners Instruction manual...

Page 17: ...nd the line switch is properly fused for the load To start burner Do not start the burner if the combustion chamber contains oil or oil vapor 1 Turn service switch OFF 2 Perform inspections and checko...

Page 18: ...Carlin part number MNEZ123 Rev 01 12 10 17 Model EZ 1 2 3 oil burners Instruction manual...

Page 19: ...ake sure the burner and appliance are correctly wired and the line switch is properly fused for the load To start burner Do not start the burner if the combustion chamber contains oil or oil vapor 1 T...

Page 20: ...Carlin part number MNEZ123 Rev 01 12 10 19 Model EZ 1 2 3 oil burners Instruction manual...

Page 21: ...voltage reading indicates incorrect wiring that must be corrected before attempting to operate the burner 5 Alarm terminals provide a 24 vac rated dry contact suitable for use with security fire alarm...

Page 22: ...Carlin part number MNEZ123 Rev 01 12 10 21 Model EZ 1 2 3 oil burners Instruction manual...

Page 23: ...e personal injury or death Use combustion test equipment to verify that the burner is properly set 5 up for your installation Appliances with positive pressure in the chamber may require a wider air o...

Page 24: ...s found Verify burner appliance operation Check burner appliance controls operation Test operating and limit controls on appliance as specified in appliance instructions Check operation of the primary...

Page 25: ...assembly 4 nominal approx 5 3 4 oal EZ 1 only 56804 25 Blower wheel 5 1 16d x 2w 77933 Nozzle line adaptor assembly 5 nominal approx 6 3 4 oal 56820 26 Primary control consult factory for other contro...

Page 26: ...Carlin part number MNEZ123 Rev 01 12 10 25 Model EZ 1 2 3 oil burners Instruction manual 7 Repair parts continued...

Page 27: ...replace a component or disassemble any part of the burner for service maintenance perform a complete operational test after reassembly to verify the burner operates correctly Failure to verify operat...

Page 28: ...ro Burners that fall within the extended warranty period such defective parts should be returned freight prepaid to Carlin The repaired component or replacement part will be provided to the Customer f...

Page 29: ...at all Never attempt to use gasoline as a fuel for this burner as it is more combustible and could result in a serious explosion Never attempt to burn refuse or use any fuel other than 1 or 2 heating...