Carlin 60200FR Installation And Operating Instructions Manual Download Page 7

7

Fault History

The 60200FR stores information from the last 32 cycles in 

which a fault condition occurred. To Enter the Fault History 

, simultaneously press and hold the 

H

 and 

buttons for 2 

seconds. The display below will appear –

Press the 

button to scroll through the history of fault 

conditions. Fault 1 is the most recent cycle in which a fault 

occurred. To view faults experienced in earlier run cycles, 

continue to press the 

button. The control will display Fault 

2 followed by Fault 3, etc. 
 

To view the details of any fault (ex. Fault 1 in the screen 

above), press the 

H

 button to see the Fault Message.  

 

Press the 

H

 button again to determine how many cycles ago 

the fault occurred.
 

Press the 

H

 button again to determine if the fault resulted in a 

lockout or a recycle.
 

Press the 

H

 button again to examine the Microamps at the 

time of the fault.

View 13 Faults

To Exit Hold

Total History 

To Exit Hold 

Carlin Combustion Technology, Inc.

MN60200FR1  070319

Fault 1 Message

No Flame Check Vlv

Fault 1 

X X X X  cycles ago

Fault 1 Result 

Lockout

Fault 1 

0.1 uAmps

Continue pressing the 

H

 button to examine the following 

information recorded during the fault cycle.

• Line Voltage  

 

• Recycle (Yes or No)

• Motor Amps (OK or Low) 

• Burn Time

• Ignitor Amps (OK or Low) 

• Flame Delay

• Valve Amps (OK or Low)

On any fault detail screen listed above, the 

E

 button can be 

pressed to view the same data in the previous fault cycle. For 

example, if in Fault 1 (the most recent fault), the Ignitor Amps 

were low, by pressing the 

E

 button, the Ignitor Amps in Fault 

2 (the previous fault cycle) will be displayed.

To Exit Fault History: Press and hold the 

F

 / 

ESCAPE but-

ton for 3 seconds at any time.

Total/Run History

In addition to the Fault History (left),the 60200FR also logs the 

total run history of the control. To enter this menu, simultane-

ously press the

 

E

 and 

buttons for 3 seconds. The display 

below will appear.  

To Exit Total History: Press and hold the      / ESCAPE but-

ton for 3 seconds at any time.
Press 

H

 button to scroll through the history which includes: 

• Total On Time 

• Max Line Volts

• Total Burn Time  

• Min Line Volts

• Total Burner Run Cycles 

• Total Recycles

• Faults Cleared (cycles ago)

Fault 1 Details

View Fault 2

  PRESS THE          BUTTON TO VIEW NEXT FAULT

FAULT 1

FAULT 2

FAULT 3

FAULT 4

FAULT 5

PRESS THE

BUTTONS

TO

VIEW

FAULT

DETAILS

Message

No Flame ck vlv  No Flame ck MTR

No Flame ck IGN 

No Flame ck vlv 

No Flame ck vlv 

Cycles Ago 

2

3

4

5

6

Result 

Lockout 

Lockout 

Lockout 

Lockout 

Lockout 

µAmps 

0.1

0.1

0.1

0.1

0.1

Line Volts 

114

114

114

114

114

Motor Amps 

OK 

Low

OK

OK

OK

Ignitor Amps 

OK 

OK 

Low 

OK 

OK 

Valve Amps 

Low 

OK 

OK 

Low

Low 

Recycle Y/N 

No 

No 

No 

No 

No 

Burn Time 

5 sec

5 sec

5 sec

5 sec

5 sec

Flame Delay 

4 sec

4 sec

4 sec

4 sec

4 sec

F A U L T   
H I S T O R Y

NOTE: Fault information in chart 
is representation only.

Fault 1

Ignitor Amps Low

Fault 2

Ignitor Amps OK

Summary of Contents for 60200FR

Page 1: ...ht 2019 Carlin Combustion Technology Inc Carlin Combustion Technology Inc On Board LCD Screen Fully Programmable Settings 32 Cycle Fault History Alarm Contacts Serviceman Reset Protection Blocked Vent...

Page 2: ...ection monitoring or other precautions are recommended for unattended dwellings in climates subject to sustain below freezing temperatures 7 Warning All work must be performed by a qualified and licen...

Page 3: ...3 Carlin Combustion Technology Inc MN60200FR1 070319 Wiring Commercial Gas Train 120V EZGas Pro 24V EZGas 120V Wiring must comply with local and national electrical codes and with the wiring diagram...

Page 4: ...s displayed on the screen press the E ENTER button The display will briefly indicate that the new setting has been Entered and the new setting will replace the previous setting on the second line of t...

Page 5: ...d the motor is on after the Call for Heat is satisfied to allow for evacuation of combustion gases A call for heat during Post Purge will result in a recycle Allowed Recycles Number of Recycles allowe...

Page 6: ...icates that the ignitor is energized flashes if ignitor not detected VALVE Indicates that the gas valve is energized on entry to pump prime will flash if not detected Operating Sequence With power to...

Page 7: ...ove the E button can be pressed to view the same data in the previous fault cycle For example if in Fault 1 the most recent fault the Ignitor Amps were low by pressing the E button the Ignitor Amps in...

Page 8: ...unless the Allowed Recycles is set to None in the Set up Menu A Recycle results in the burner shutting down for 60 seconds then resuming operation in Standby if there is no Call for Heat or initiatin...