Inputs and Outputs
08.16
Operating Manual
25
x
11
x
x
1
2
PS connection with internal power supply:
Connector CON3 (I/O)
(I/O, 16-pin)
(DC coupled)
+VCC
PS input
GND ext.
With external power supply Jumper 1 (3-4; 5-6) must be inserted.
Potential-free
o
r
ele
ctro
nica
l rela
is
Prod.sensor (PS)
Figure 14
7.5 External Power Supply
PS connection (NPN/push-pull) with external power supply:
(DC-isolated)
x
4
x
5
x
6
x
1
x
2
NPN
1
+Ub external
24VDC +/- 10%
GND external
Connector CON2 (PS/encoder)
(Product sensor, 7-pin)
+Ub external
+Ub internal
PS input
GND internal
GND external
Prod.sensor
J2 is to be inserted into 2-3 (default)
Figure 15
PS connection (PNP/push-pull) with external power supply:
(DC-isolated)
x
4
x
5
x
6
x
1
x
2
+Ub external
24VDC +/- 10%
GND external
PNP
2
Connector CON2 (PS/encoder)
(Product sensor, 7-pin)
+Ub external
+Ub internal
PS input
GND internal
GND external
Prod.sensor
J2 is to be inserted into 2-3 (default)
Figure 16