![Carl Valentin Dynacode IP Series Operating Manual Download Page 116](http://html1.mh-extra.com/html/carl-valentin/dynacode-ip-series/dynacode-ip-series_operating-manual_2558368116.webp)
Ribbon Save / Foil Saving
Dynacode IP Serie
118
Operating Manual
08.16
Press key
to arrive the next menu item.
PHupT = printhead up time in ms:
Is used from ribbon save algorithm to calculate if a field ribbon save
can be made or not.
PhVReactT = valve reaction time in ms:
It is calculated when the printhead upwards movement is started.
Press key
to arrive the next menu item.
RibMotStpDlayT = ribbon motor stop delay time
Decelaration time in ms in which the transfer ribbon motor is still
moved with constant speed before stopping.
This can be used to correct black bars at the end of print or to provide
a longer cooling for the printhead.
Press key
to arrive the next menu item.
FieldRS = field ribbon saving:
Off:
Field ribbon save mode Off.
PHOnly:
Only the printhead is moved. The transfer ribbon is not
stopped.
Normal:
Field ribbon save is executed only if the transfer ribbon motor
is completely stopped.
Strong:
Field ribbon save is executed, even if the transfer ribbon
motor is not stopped.
Rwind v = rewind speed in mm/s:
Indication of rewind in mm/s.
Press key
to arrive the next menu item.
If 0 (default value) is set, the parameter has no influence to the ribbon
save. Otherwise the ribbon save algorithm does not use the measured
speed for the calculation of layout ribbon save but the speed that is
indicated here.
Press key
to arrive the next menu item.
Indication of length, which is transported forward after measuring the
transfer ribbon.
Printhead up time
Valve reaction time
Ribbon mortor
stop delay time
Field ribbon saving
Rewind speed
Speed 1. Field
Tension