23
ENG
“Wellness” +0300060EN - rel. 1.2 - 03.09.2012
installer
user
ser
vice
If enabled time bands, and you want to change the state machine (OFF
ON), or the setpoint, the following screen appears:
Regolation tmed
ATTENTION: the system follows the bands
range
modify:
status
ON/OFF
Setpoint
... °C
Fine
date and hour
Reg. timed (*)
NOT ACTIVE /
ACTIVE
(*) if activated the Regolation tmed, the line “change” becomes:
Reset
YES/NO
This method breaks the Regolation tmed for time impostated in date
and hour.
Fill essence
range
default
U.M.
Fill essence
1*
ON/OFF
OFF
Fill essence
2*
ON/OFF
OFF
Fill essence
3*
ON/OFF
OFF
Sanitation
ON/OFF
OFF
select ON for the time necessary to fi ll the circuit selected essence, then
back to OFF.
Activation Sanitation
Password Sanitation
0077
Press ENTER to confi rm.
ATTENTION: secure that there are people bath
range
default
Active cycle of sanitation
YES/NO
NO
Attention:
•
the mask “Rapid Selection” show only the functions enables in phase
of confi guration
•
if the humidifi er is enable but not prducing steam, check the following
possible causes:
possible cause
soluction
the temperature of the steam bath is
higher than the set point
wait for the temperature of the
bath to fall below the set point
alarms are active that stop steam
production (ALARM button fl ashing)
check and resolve the error (see
par.10)
The humidifi er is set to “Manual”
deactivate tha manual procedure
(from Maintenance Menù)
time bands are active (CLOCK icon
fl ashing on the display)
disable the time band (from User
Menù ), or modify as required
Tab. 5.a
5.8 “INFO” screen (read-only)
Series of read-only screens for displaying the main humidifi er status
values. To access, press PRG from the “Rapid Selection” screen. There are 2
“INFO” screens ,to move from one screen to the next, press UP or DOWN.
Press ESC to return to the “Main” screen.
“INFO” screens:
Info 1/2
display
U.M.
Status
(*)
Activity
Steam production
value
kg/h
Current
value
A
Fill valve
value
drain pump
value
(*) humidifer status:
•
Operating:
steam production in progress;
•
Alarms
: signalling of one or more alarms;
•
OFF by Superv
.: steam production disabled by supervisor;
•
OFF by Sched.:
steam production disabled during a pre-set
sheduler;
•
Remote Off:
isteam production interrupted through the opening of
the “Remote ON/OFF” contact;
•
OFF by Keyb.:
steam production disabled by keyboard (see “SET”
mask);
•
Manual Proc.:
humidifer fuctions managed manually (maintenance
menu > manual procedure);
•
No request:
humidifer on, without steam production request.
Info 2/2
display
UOM
Work hours
value
h
Cyl.work hours(**)
value
h
Conductivity
value
μS/cm
Alarm relay
time bands
(*) cylinder status:
•
Off
: stop steam production (no request or signalling of an alarm)
•
Softstart
: starting steam production;
•
Operating
: steady operation steam production;
•
Low Prod
.: low production;
•
Washing
: cylinder washing in progress.
(**) Activity of the cylinder:
•
Cyl.Off
: stop steam production (no request or signalling of an alarm);
•
Fill
: fi ll valve operating;
•
Evaporation
: steam production operating;
•
Drain
: drain pump operating;
•
Stop by Al.
: steam production stopped by an alarm;
•
Inact.Drain
: total drain for inactivity;
•
Pre-clean
: new cylinder washing in progress;
•
M. Emptying
: manual drain;
•
Chk.F.Water
: fi ll water check (from lack of water cylinder alarm);
•
Period FI:
Periodical drain for dilution.
5.9 “Alarms” screen
Fig. 5.e
Indicates an alarm is active, press to display.