65
ENG
“heaterSteam” +0300075EN - rel. 1.2 - 29.09.2015
12.7 Variables accessible in serial mode only
Description
Type
SPV CAREL
R/W
NOTES
St: ambient setpoint
I
1
Release software
I
81
R
Humidifi er status
0
Start
7
Water fi ll-up
1,2,3,4
Autotest
8
Water drain
5
No production
9
AFS drain
6
Steam production in progress
10
Block alarm
I
83
R
Block alarms
b0
EE alarm
b4
Er alarm
b1
Not used
b5
Et alarm
b2
EC alarm
b6
E0 alarm (as b7)
b3
EL alarm
b7
E0 alarm
I
84
R
Bit setup: b7 = bit 7,
bit = 1 means alarm enabled
Alarms with humidifi er disablement
b0
EF alarm
b4
E4 alarm
b1
EP alarm
b5
E5 alarm
b2
Warning Ed
b6
Not used
b3
E3 alarm
b7
E1 alarm
I
85
R
Bit setup: b7 = bit 7,
bit = 1 means alarm enabled
Warning
b0
Warning E
b4
Warning EU
b1
Warning E_
b5
Warning CL
b2
Warning
b6
Warning Ec
b3
Warning EA
b7
Warning E2
I
86
R
Bit setup: b7 = bit 7,
bit = 1 means alarm enabled
Command via RS485
1
Reset alarms
2
Hour counter reset
I
95
Response upon RS485 call
1
Command completed successfully
2
Command completed unsuccessfully
3
Command failed
I
96
Humidifi er disabled via remote ON/OFF or via terminals 7I-8I contacts or setting D15 =1
(see below for D15)
D
9
R
Water level < min level
D
10
R
Water level > operating level
D
10
R
Serial disablement command:
1 = humidifer disabled
0 = humidifi er enabled
D
15
R/W
Similar to remote on/off
command
Humidifi er ready upon request
D
17
R
Humidifi cation request present
D
19
R
Pre-heating command in progress
D
20
R
Tab. 12.g
Description Type
SPV
CAREL
R/W
NOTES
Reset hardware
D
24
It produces an eff ect similar to shutdown and subsequent restart of the humidifi er: if D24 is set to 1,
control restarts as it would have been unpowered and powered again.
To be sent in the following cases:
•
to set the new serial address after having changed c3;
•
to restart the humidifi er as it would have been unpowered and powered again.
EE alarm
D
33
R
EC alarm
D
35
R
Er alarm
D
37
R
Et alarm
D
38
R
E0 alarm
D
39
R
E1 alarm
D
40
R
EF alarm
D
41
R
EP alarm
D
42
R
Ed alarm
D
43
R
E3 alarm
D
44
R
E4 alarm
D
45
R
E5 alarm
D
46
R
E1 alarm
D
48
R
Warning E–
D
49
R
Warning E_
D
50
R
Warning E–
D
51
R
Warning EA
D
52
R
Warning EU
D
53
R
Warning CL
D
54
R
Warning Ec
D
55
R
Warning E2
D
56
R
Tab. 12.h
Summary of Contents for heaterSteam UR Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 70: ...70 ENG heaterSteam 0300075EN rel 1 2 29 09 2015 Notes...
Page 71: ......