Carefree of Colorado
Service
Manual
M
IRAGE
2-S
TAGE
052588-301r4
25
C
ONNECTION
F
LEX W
/
"110VDR"
C
ONTROL
B
OXES
The wiring diagrams show the standard installation for multiple awning configurations. For control boxes marked
w/ "110VDR", the installer may adjust the cable interconnections for greater flexibility during installation.
1. The key pad may be installed in the unused DSK port of any board with the jumper cables sequentially
connected from the AUX port to the DSK port of the next board.
Example: Placing the keypad in the DSK of Board 3.
2. The RF Receiver and the optional ignition lock-out can be plugged into any unused "EYE" port. It is not
necessary to use the splitter as shown in the diagrams.
3. The "110VDR" control boxes are compatible with integrator interfaces. Contact Carefree engineering
for information and system requirements.
O
PTIONAL
M
ANUAL
B
YPASS
S
WITCH
Installers may elect to install a manual bypass switch for testing or
emergency operation of the awning. The simple switch allows the
operator to extend or retract the awning without using the keypad
control panel. For multiple awning installations, a separate switch
must be installed for each awning.
1. Open the control box and identify the terminal block next to
the phone cord jacks.
2. Connect the switch to the terminal block as shown in the
diagram.
The switch is a single pole, double throw, momentary ON, center
OFF. Components are installer furnished.
Key Pad
DR024
AMD
SUN
AUX
EYE
DSK
AMD
SUN
AUX
EYE
DSK
AMD
SUN
AUX
EYE
DSK
AMD
SUN
AUX
EYE
DSK
Motor 1
Motor 2
Motor 3
Motor 4
Common
Extend
Retract
Manual Switch
Single Pole, Double
Throw, Momentary ON,
Center OFF
DR011